Application
Shielded wall luminaires with integral passive infrared motion and light
sensor for use in an existing DALI system.
A luminaire made of aluminium alloy and crystal glass.
Product description
Luminaire made of aluminium alloy, aluminium and stainless steel BEGA Unidure
® coating technology Colour graphite, silver or white Crystal glass, white
inside 2 mounting holes ø 4.5 mm Distance apart 236 mm 2 screw cable glands
with strain relief for through-wiring power connecting cable ø 7–12 mm 1 screw
cable gland closed at the factory with a dummy plug Connection terminal 2.5
Earth conductor connection Passive infrared motion sensor (PIR) Range up to 10
m Horizontal opening angle 110° Vertical opening angle 93° Minimum temperature
difference between moving object and environment 4 °C Object speed 1 m/s Light
sensor Measuring range adjustable using DALI Cockpit 0-2500 lx, Resolution 1
lx Power consumption on the DALI bus: Sensor: 3.5 mA
Power supply unit: 2 mA Time hysteresis for suppressing rapid fluctuations in
brightness ED power supply unit 220-240 V 0/50-60 Hz DC 176-280 V DALI-
controllable Basic insulation is provided between the mains and control cables
BEGA Thermal Switch® Temporary thermal shutdown to protect temperature-
sensitive components Safety class I Protection class IP 65 Dust-tight and
protection against water jets Impact strength IK05 Protection against
mechanical impacts < 0.7 joule
**– Conformity mark
Weight:** 3.1 kg
This product contains light sources of energy efficiency class(es) B, C
Lamp
Module connected wattage| 7.7 W
Luminaire connected wattage| 10.5 W
Rated temperature| ta = 25 °C
Ambient temperature| ta max = 35 °C
24 347 K3
Module designation| LED-0276/830
Colour temperature| 3000 K
Colour rendering index| CRI > 80
Module luminous flux| 1505 lm
Luminaire luminous flux| 644 lm
Luminaire luminous efficiency| 61,3 lm / W
24 347 K4
Module designation| LED-0276/840
Colour temperature| 4000 K
Colour rendering index| CRI > 80
Module luminous flux| 1545 lm
Luminaire luminous flux| 661 lm
Luminaire luminous efficiency| 63 lm / W
Configuration
The easy to use DALI Cockpit software for DALI systems configurations and for monitoring communication on the DALI bus can be downloaded from our website: https://www.bega.com/dali-cockpit Configuration is also possible via smartphone and tablet using the BEGA Tool app in conjunction with Bluetooth DALI gateway 71 075 or 71 151.
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Range / Detection area
The specifications for the range and detection area of the PIR motion sensor
are reference values. The detection area is up to 110° horizontally and 93°
vertically, with a depth of max. 10 m depending on the direction of motion
(see sketch).
Too minor temperature difference between the moving object and the ambient
temperature can influence the detection range.
Local conditions and external heat sources may affect both the range and the
detection area. Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Installation
Please note:
A separate DALI power supply is required to operate the luminaire.
If this is not provided by the customer, we recommend using DALI power supply
71 094 or 70 866 (see accessories).
Undo hexagon socket head screw (wrench size 3 mm) through the opening in the
luminaire housing up to the stop and lift luminaire top.
Disconnect the earth conductor connection from the plug connection.
Disconnect plug-connection of the LED connecting cable.
Orientation of the sensor
The sensor is factory-configured for the maximum detection area.
In order to avoid the unintentional adjustment of the sensor in public areas,
the alteration of the factory setting must be made before the luminaire base
is mounted.
To do so, loosen the two rear screws (Torx
driver T10) slightly and rotate the sensor ball to the desired position (see
Fig. A). In the process, make sure that the light sensor embedded in the
sensor ball is not directed upwards or covered by the edge of the surrounding
housing! (see Fig. B) Tighten the mounting screws evenly.Lead the
mains supply cable through the screw cable gland into the luminaire back
housing.
Notice position of use “arrow down” of the luminaire back plate.
The installed black gasket insert is intended for cables ø < 10 mm.
For cables ø 10-12 mm the enclosed grey gasket insert must be used.
In case of through-wiring replace the factory installed dummy plug with the
enclosed corresponding gasket insert.
At the same time, use the enclosed synthetic cone-thrust collar between gasket
insert and thrust screw (wrench size 22 mm) (see sketch).Notice
position of use “arrow down” of the luminaire back plate.
Fix luminaire base with enclosed or any other suitable fixing material onto
the mounting surface.
Tighten screw cable gland.
Make the earth conductor connection and the electrical connection.
For digital control please use the connecting terminal DA, DA.
In case this terminal is not used the luminaire will be operated at full light
output.
In order to guarantee the maximum service life of the electrical components,
the enclosed desiccant pouch must be placed in the luminaire.
Remove the desiccant pouch from the foil packaging and place it in the
position marked by the red information label immediately before finally
closing the luminaire.
Make earth conductor connection between luminaire top and luminaire base.
Push plug into coupler as far as it will go.
Make sure that gasket is positioned correctly.
Install luminaire top and tighten.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Functions and settings
A combination of several DALI motion and light sensors in one DALI line is
possible.
Following installation, the PIR motion and light sensor can be immediately
operated in its factory settings; configuration is not required in this case.
The factory settings as are follows: Holding time: 5 min
Brightness threshold: almost dark /100 lx
Target address: broadcast
Constant light control: off
Status display: Green LED off
(can be activated and deactivated using the DALI Cockpit software)
Time hysteresis: 1 min
Threshold hysteresis: 0 lx
Function testing:
After the power supply and the DALI power supply have been switched on, the
luminaire is switched on for the duration of hysteresis (factory setting 1
min).
After this period has expired, the lighting switches off automatically.
If the lighting does not switch on again automatically (after the end of
hysteresis) during commissioning or on the return of power, the light sensor
must be darkened for the duration of hysteresis.
If the brightness threshold is exceeded (factory setting “almost dark /100
lx“), a movement in the detection area does not cause the lighting to switch
itself on.
For function testing, the light sensor must be darkened.
Brightness must be below the threshold for the duration of hysteresis; only
then does a movement in the detection area cause the lighting to switch itself
on.
The lighting now remains switched on for the duration of the holding time
(factory setting 5 min).
If there are any more movements in the detection area, the holding time starts
over again.
Movement in the detection area does not cause the lighting to switch itself on
when the holding time has expired and the brightness threshold has been
exceeded for the duration of hysteresis.
DALI configuration
To adjust the settings and for additional functions such as basic brightness
(luminaire switches to adjustable dimming value 1 if the brightness threshold
is not reached and to adjustable dimming value 2 if movement is detected), a
DALI USB interface (71 024 or
71 054) and the DALI Cockpit software are additionally required. DALI Cockpit
is available as a free download from our website at
www.bega.com.
A reset to the factory settings is performed via the DALI reset in the DALI
Cockpit software.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.
Please note:
After replacing the LED module, the PIR motion and light sensor of the
luminaire must be reconfigured (see section Commissioning).
To do so, you must use the QR code enclosed with the replacement module.
Please paste the additional enclosed QR codes over the QR codes in
documentation provided by the customer.
Accessories
71 094| DALI Power supply 30 mA in switch and cavity boxes or installed cable
connection box
---|---
70 866| DALI Power supply 240 mA for DIN rail mounting
A separate instructions for use can be provided upon request.
Spares
Spare glass| 11 003 526
LED power supply unit| DEV-0409/700i
LED module 3000 K| LED-0276/830
LED module 4000 K| LED-0276/840
Gasket housing| 83 001 780
Gasket glass| 83 001 907
BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com
www.bega.com
IP 65
Documents / Resources
| BEGA
24347 Wall Luminaire with PIR Motion and Light
Sensor
[pdf] Instruction Manual
24347K3, 24347K4, 24347 Wall Luminaire with PIR Motion and Light Sensor, Wall
Luminaire with PIR Motion and Light Sensor, Luminaire with PIR Motion and
Light Sensor, PIR Motion and Light Sensor, Light Sensor
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>