BEGA 33328 Shielded Ceiling Wall and Pillar Luminaire Instruction Manual
- June 1, 2024
- BEGA
Table of Contents
Technical amendments reserved
Decken · Wand · Pfeilerleuchte
Ceiling · Wall · Pillar luminaire
Plafonnier · Applique · Luminaire de pilastre
33 328
Instructions for use
Application
Shielded ceiling, wall and pillar luminaire with high protection class.
A luminaire made of aluminium alloy and impact resistant crystal glass with
light diffusing structures.
The colour temperature of the luminaire can be set optionally to 3000 K and
4000 K.
Product description
Luminaire made of aluminium alloy, aluminium and stainless steel BEGA Unidure®
coating technology Colour graphite or silver Crystal glass, white inside 2
mounting holes ø 5.5 mm Distance apart 144 mm 2 cable entries for through-
wiring of mains supply cable ø 7-10.5 mm Connection terminal 2.5@ Earth
conductor connection BEGA Ultimate Driver® Complies with flicker requirements
in accordance with IEEE 1789, DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit 220-240 V 0/50-60 Hz DC 176-280 V BEGA Thermal
Control®
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire Safety class I Protection class IP 65
Dust-tight and protection against water jets Impact strength IK08 Protection
against mechanical impacts < 5 joule
– Safety mark
– Conformity mark
Weight: 2.8 kg
This product contains light sources of energy efficiency class(es) C
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
The ideal protection of all electronic components installed in the luminaires
is achieved by using bounce-free switching contacts such as an electronic
relay (solid-state relay), e.g. BEGA 71 320.
Installation
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
Undo screws.
Remove frame and glass with gasket.
Lead the mains supply cable through the cable entry of the luminaire base.
Fix luminaire base with enclosed or any other suitable fixing material onto
the mounting surface.
Be sure to use the gasket rings supplied.
Make the earth conductor connection and the electrical connection.
The colour temperature of the LED module was set to 3000 K by default (switch
position 1: “on”, 2: “off”).
For colour temperature 4000 K, the switch
position 1: “off” and 2: “on” must be selected.
Switching may only be carried out when disconnected from the power supply!
Insert glass with gasket and frame.
Make sure that the gasket is positioned correctly.Tighten screws evenly.
Lamp
Module connected wattage | 3.8 W |
---|---|
Luminaire connected wattage | 4.7 W |
Module designation | LED-1435/83040 |
Colour rendering index | CRI > 80 |
Rated temperature | ta = 25 °C |
Ambient temperature | ta max = 60 °C |
Operation at colour temperature | 3000 K |
Module luminous flux | 720 lm |
Luminaire luminous flux | 378 lm |
Luminaire luminous efficiency | 80,4 lm / W |
Operation at colour temperature | 4000 K |
Module luminous flux | 770 lm |
Luminaire luminous flux | 404 lm |
Luminaire luminous efficiency | 86 lm / W |
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.
Spares
Spare glass 11 002 814 11
LED power supply unit DEV-0450/350
LED module LED-1435/83040
Gasket glass 83 001 831
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden ·
info@bega.com · www.bega.com