BEGA 33328 Shielded Ceiling Wall and Pillar Luminaire Instruction Manual

June 1, 2024
BEGA

Technical amendments reserved
Decken · Wand · Pfeilerleuchte
Ceiling · Wall · Pillar luminaire
Plafonnier · Applique · Luminaire de pilastre
33 328

BEGA 33328 Shielded Ceiling Wall and Pillar Luminaire - Fig
1

Instructions for use

Application

Shielded ceiling, wall and pillar luminaire with high protection class.
A luminaire made of aluminium alloy and impact resistant crystal glass with light diffusing structures.
The colour temperature of the luminaire can be set optionally to 3000 K and 4000 K.

Product description

Luminaire made of aluminium alloy, aluminium and stainless steel BEGA Unidure® coating technology Colour graphite or silver Crystal glass, white inside 2 mounting holes ø 5.5 mm Distance apart 144 mm 2 cable entries for through- wiring of mains supply cable ø 7-10.5 mm Connection terminal 2.5@ Earth conductor connection BEGA Ultimate Driver® Complies with flicker requirements in accordance with IEEE 1789, DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit 220-240 V   0/50-60 Hz DC 176-280 V BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire Safety class I Protection class IP 65
Dust-tight and protection against water jets Impact strength IK08 Protection against mechanical impacts < 5 joule
– Safety mark
– Conformity mark
Weight: 2.8 kg
This product contains light sources of energy efficiency class(es) C

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71 320.

Installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.
Undo screws.
Remove frame and glass with gasket.
Lead the mains supply cable through the cable entry of the luminaire base.
Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface.
Be sure to use the gasket rings supplied.
Make the earth conductor connection and the electrical connection.

BEGA 33328 Shielded Ceiling Wall and Pillar Luminaire - Fig
2

The colour temperature of the LED module was set to 3000 K by default (switch position 1: “on”, 2: “off”).
For colour temperature 4000 K, the switch
position 1: “off” and 2: “on” must be selected.
Switching may only be carried out when disconnected from the power supply!
Insert glass with gasket and frame.
Make sure that the gasket is positioned correctly.Tighten screws evenly.

Lamp

Module connected wattage 3.8 W
Luminaire connected wattage 4.7 W
Module designation LED-1435/83040
Colour rendering index CRI > 80
Rated temperature ta = 25 °C
Ambient temperature ta max = 60 °C
Operation at colour temperature 3000 K
Module luminous flux 720 lm
Luminaire luminous flux 378 lm
Luminaire luminous efficiency 80,4 lm / W
Operation at colour temperature 4000 K
Module luminous flux 770 lm
Luminaire luminous flux 404 lm
Luminaire luminous efficiency 86 lm / W

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.

Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.

Spares
Spare glass 11 002 814 11
LED power supply unit DEV-0450/350
LED module LED-1435/83040
Gasket glass 83 001 831
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · [email protected] · www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BEGA User Manuals

Related Manuals