Application
Wall luminaire · indoor luminaire made of handblown opal glass and metal housing, for all lighting tasks in interior applications.
They are ideal for places where a soft and uniform lighting distribution is required.
Luminaire with a high protection class.

BEGA-23-259.6-Wall-Luminaire-For-Indoor-Use-1

Product Description

  • Luminaire made of Aluminium,
  • finish Colour velvet copper
  • Hand-blown opal glass
  • Two elongated mounting holes
  • Width 6 mm · 450 mm spacing
  • Insulating housing with cable entry for mains supply cable up to ø 10,5 mm, max. 3 x 1,5@
  • Connection terminal 2.5@
  • Earth conductor connection
  • Complies with flicker requirements in accordance with IEEE 1789,
  • DIN IEC/TR 63158, DIN IEC/TR 61547-1
  • LED power supply unit 220-240 V x 0/50-60 Hz
  • DC 198-280 V
  • BEGA Thermal Switch®
  • Temporary thermal shutdown to protect temperature-sensitive components
  • Safety class I
  • Protection class IP 44
  • Protected against granular foreign bodies
  • ≥ 1 mm and splash water
  • Impact strength IK02
  • Protection against mechanical impacts < 0.2 joule
  • r – Safety mark
  • c – Conformity mark
  • Weight: 2.6 kg
  • This product contains light sources of energy efficiency class(es) D

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com

Lamp

Module connected wattage                  19.2 W

Luminaire connected wattage               22.4 W
Rated temperature                            ta = 25 °C
Ambient temperature                    ta max = 35 °C

23 259.6 K3

Module designation              3x LED-0425/930

Colour temperature                              3000 K
Colour rendering index                       CRI > 90
Module luminous flux                          3165 lm
Luminaire luminous flux                      2170 lm
Luminaire luminous efficiency          96,9 lm / W

23 259.6 K4

Module designation              3x LED-0425/940

Colour temperature                              4000 K
Colour rendering index                       CRI > 90
Module luminous flux                          3345 lm
Luminaire luminous flux                      2293 lm
Luminaire luminous efficiency        102,4 lm / W

Insulation housing

BEGA-23-259.6-Wall-Luminaire-For-Indoor-Use-2

Installation

For mounting and dismantling please keep a minimum distance of 450 mm between the removable cap and the wall.
LEDs are high-quality electronic components!Please avoid touching the light output opening of the LED directly during installation or relamping.

Open luminaire:
Loosen knob, remove cap and glass.
Drill mounting holes into the mounting surface – spacing 450 mm.
For the mains supply connecting open the insulation housing – pull open – strip mains supply cable max. 15 mm and lead it into the insulation housing – see sketch.
Make earth conductor connection and electrical connection.
Connect both parts of the insulation housing until they audibly engage.

The outer coating of the cable has to be fully enclosed by the compression nipple.
Fix luminaire with enclosed or any other suitable fixing material onto the mounting surface. Remove bubble wrap underneath LED module. Place glass into luminaire housing, close luminaire with the cap and screw in knob into the cap.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.
Defective glass must be replaced.

Replacement of the LED module

The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
Disconnect the system.
Loosen lateral knob, remove cap and take out glass.
Please follow the installation instructions for the LED module.
Defective glass must be replaced.
Insert glass into luminaire housing, close luminaire with the cap and screw in knob into the cap.

Spares

Spare glass 11 002 949 .1R G
LED power supply unit DEV-0352/1000
LED module 3000 K LED-0425/930
LED module 4000 K LED-0425/940
Gasket 83 001 179

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com