BEGA 95023 Charging Point with Integrated Charging Unit Instruction Manual
- May 15, 2024
- BEGA
Table of Contents
Charging point
95 023 IP 54
Installation instructions
Application
Charging point 270 x 270 mm with integrated charging unit for bolting onto a
foundation or anchorage unit with particularly robust design for semi-public
areas.
A detailed guide for commissioning the charging unit can be found in the
operating instructions enclosed separately.
Safety
The installation and operation of this charging unit are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
Should the charging unit be subsequently modified, the persons responsible for
the modification shall be considered the manufacturer.
Prior to installation, please note:
The supply line for each charging unit must have corresponding safeguards with
automatic cutout and residual current circuit breaker.
We also recommend the use of overvoltage protection.
For the electrical connection, a corresponding connection box is required.
For this purpose, we recommend using the BEGA connection box 71 306 with
integrated residual current automatic cutout and overvoltage protection (see
accessories).
Standards
DIN EN IEC 61851-1,
DIN EN 61439-7,
DIN EN IEC 61000-6-2,
DIN EN 61000-6-3
Guidelines
Low Voltages Directive 2014/35/EU,
EMV Directive 2014/30/EU,
RED Directive 2014/53/EU,
ROHS Directive 2011/65/EU,
WEEE Directive 2012/19/EU
Product description
Extruded aluminium profile frame, colour graphite
Side parts and head plate made of UV-resistant and waterproof high-pressure
laminate
Décor Marshland Oak (MO) or Polar Oak (PO)
Carrier system and mounting plate made of hot-dip galvanised steel in
compliance with EN ISO 1461 for bolting onto a foundation or an anchorage unit
Mounting plate with 4 elongated holes.
Width 11 mm
Pitch circle ø 200 mm
Integrated charging unit with connecting cable H07RN-F 5 G 6@
Cable length 2 m
Housing made of aluminium, aluminium alloy and stainless steel
Ethernet data cable Cat 6A with plug RJ45
Length 1.5 m
Jack part for connection to on-site data cable
Integrated DC fault current detection 6 mA
Fuse protection, overvoltage protection and RCD protective switch must be
provided by the customer
Voltage 230/400 V AC, 50 Hz (1 or 3 phases) for connection to 230/400 V four-
wire system
Current 16/32 A
Load contactor 4-pole, 40 A
Control fuse 1-pole, B6
DC trigger current I∆DC 0.006 A
For TN and TT mains systems
Socket type 2 pursuant to EN 62196 with integrated status light
Charging capacity 3.7–22 kW
MID-compliant energy meter (kWh)
Compliant with calibration regulations pursuant to MessEV
Integration into load and charging management possible
Authorisation via RFID card reader
For the implementation of a charging station pursuant to the Charging Columns
Ordinance, coupling with the BEGA payment terminal is possible for common
payment methods – see accessories
Communication with backend via LTE using
OCPP 1.6 JSON
Operating temperature range: -25°C to 45°C
C-rail with 2 M6 sliding nuts to accommodate an on-site connection box in
accordance with DIN 43628 / VDE 0660 for the connection of the charging unit
Protection class IP 65
Dust-tight and protected against water jets
Socket (with closed flap)
Protection class IP 54
Protection against harmful dust deposits and splash water
Impact strength IK10
Protection against mechanical impacts < 20 joule
– Conformity mark
Weight: 81.6 kg
Installation
The base of the charging point must not be lower than the upper edge of the
floor covering.
A cable length of 0,5 m above the mounting surface is required for the
electrical connection of the charging unit.
Unscrew the hexagon socket screw (wrench size 6) in the head plate and lift
off the head plate. Pull both side parts upward and out of the corner
profiles.
Route the underground cable and data cable through the opening in the mounting
plate. Attach the mounting plate to a foundation or anchorage unit (Accessory
70 897).
Installation of the charging unit in the carrier system (see drawing):
Screw both of the enclosed mounting pins tightly into the threaded holes on
the back of the charging unit (hexagon socket wrench size 6) to attach the
charging unit. Unscrew the four lateral mounting screws (hexagon socket
wrench size 4) in the carriersystem.
Route the connecting cables of the charging unit through the opening into the
carrier system and insert the charging unit.
Tighten the lateral mounting screws evenly.
The electrical connection of the charging unit must be made with the
appropriate protection class and safety class using suitable connection
terminals (not included in the scope of delivery) on the connecting cable, e.
g. connection box 71306.
The connection of the data cable is made using an RJ45 plug-in device.
For this purpose, connect the on-site data cable to the plug-in device (jack
part).
Slide the two side parts downward into the corner profiles.
Replace the head plate and secure it in place.
Maintenance and Inspection
Electrical installations and equipment have to be maintained according to
approved electrical regulations only.
Regular inspections must be carried out according to national safety
regulations.
Correct operation of the residual-current circuit-breaker in the subsidiary
distribution should be tested at least once every six months by pressing the
test button T , unless other regional or user-specific tests are required
in addition.
Accessories
70 897 Anchorage unit
Anchorage unit with mounting flange made of galvanised steel. Total length 600
mm.
4 stainless steel fixing screws M 10 x 35.
71 306 Connection box IP 54 with residual current automatic cutout and
overvoltage protection
1 input for 5 x 10 cable
1 output for 5 x 6 cable
71 308 Payment terminal (wall mounting)
71 309 Payment terminal (stand version)
The payment terminal enables payment with common contactless payment methods
(credit card, smartphone etc.) at up to 8 charging points connected via
Ethernet.
For the accessories a separate instructions for use can be provided upon
request.
BEGA Gantenbrink-Leuchten KG · Postfach 31 60
58689 Menden · info@bega.com ·
www.bega.com