Specifications
- Lamp Module connected wattage: 34.7 W
- Luminaire connected wattage: 39 W
- Rated temperature: 50°C
- Service life criteria: 25,000 hours
- Colour temperature: 3000 K
- Colour rendering index (CRI): >90
- Module luminous flux: 5400 lm
- Luminaire luminous flux: 3400 lm
- Luminaire luminous efficiency: 87.2 lm / W
Product Usage Instructions
Overvoltage Protection
The electronic components in the luminaire are protected against overvoltage according to DIN EN 61547. For additional protection against transients, separate overvoltage protection components are recommended. These can be found on our website at www.bega.com.
Safety
Installation and operation of the luminaire must comply with national safety regulations. Only a qualified electrician should carry out installation and commissioning. The manufacturer will not be liable for damage due to improper use or installation. Any modifications made to the luminaire will shift responsibility to the person making those modifications.
Mounting Instructions
Position the luminaire housing at a flat inclination angle over the fastening edge of the mounting plate and swing it in. Align the luminaire housing and tighten the hexagon socket screw (wrench size 1.5) to a maximum torque of 0.25 Nm.
If you desire an additional colored wall accent, optional arched wall panels made of metal are available as accessories.
Please note: Install a wall panel only after mounting the luminaire.
Optional Accessories
For this luminaire, optional arched wall panels made of metal are available in three finishes:
- Colour velvet white – Article number: 13 341
- Colour matt brass – Article number: 13 342
- Colour velvet black – Article number: 13 343
Spare Parts
Available spare parts:
- LED power supply unit – DEV-0305/700i
- LED module 3000 K – LED-1405/930
FAQ
Can I install the wall panels before mounting the luminaire?
No, it is recommended to install the wall panels only after mounting the luminaire.
Where can I find additional overvoltage protection components?
You can find these components on our website at www.bega.com.
Wall luminaire for indoor use
Instructions for use
Application
Wall luminaire – Indoor luminaire with ring-shaped light source for unshielded
and uniform light, light-diffusing silicone diffuser and metal ring.
As single luminaires or in arrangements, they are creative lighting design
solutions for interior design.
Product description
Ring made of metal, finish colour matt brass Luminaire housing made of
synthetic material, finish colour velvet white Round inlay made of metal,
finish colour matt brass Diffusor made of translucent ageing-resistant
silicone Mounting plate with 2 fixing holes ø 6 mm · 85 mm spacing 2 cable
entries for through-wiring of mains supply cable ø 7-10.5 mm, max. 5 G 1.5@
Connecting terminals 2.5@ Earth conductor connection 2-pole connection
terminals for digital control LED power supply unit 220-240 V x 0/50-60 Hz DC
196-250 V DALI-controllable
Number of DALI addresses: 1 Basic insulation is provided between the mains and
control cables BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire Safety class I
Conformity mark
This product contains light sources of energy efficiency class(es) D
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website a www.bega.com.
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Lamp
-
Module connected wattage 34.7 W
-
Luminaire connected wattage 39 W
-
Rated temperature ta = 25 °C
-
Service life criteria 50 000 h / L70
51 273.4 K3 -
Module designation LED-1405/930
-
Colour temperature 3000 K
-
Colour rendering index CRI > 90
-
Module luminous flux 5400 lm
-
Luminaire luminous flux * 3400 lm
-
Luminaire luminous efficiency * 87,2 lm / W
preliminary data
Installation
- LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
- Undo the hexagon socket head screw (wrench size 1,5 mm) and remove mounting plate from luminaire housing.
- Pass the power connecting cable through the cable entry in the mounting plate. Note position of application of the mounting plate “arrow down”.
- Fasten the mounting plate with the supplied fastening material or other suitable fastening material to the installation surface.
- Establish earth conductor connection to the earth conductor connection screw and make the electrical connection to the terminals. The two connecting terminals marked DA, DA are provided for digital control purposes.
- If these terminals are not assigned, the luminaire will work with full light output.
- Insert the connection terminals into the luminaire housing.
Position the luminaire housing in a flat inclination angle over the fastening
edge of the mounting plate and swing in.
Align luminaire housing and tighten (max. 0.25 Nm) hexagon socket screw
(wrench size 1.5).
If an additional coloured wall accent is desired, arched wall panels made of
metal are optionally available – accessories.
Please note: The installation of a wall
panel should always be carried out after the installation of the luminaire.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
- The designation of the LED module is noted on a label in the luminaire.
- The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
- Disconnect the system from the power supply. Undo the hexagon socket head screw (wrench size 2.5 mm) and remove luminaire from mounting plate.
- Remove the connecting lines from the terminals and place the front of the luminaire on a soft surface.
- Open the luminaire housing:
- First loosen the two outer Torx screws (T20), then the 4 inner Torx screws (T20). Disconnect the lines of the luminaire cable from the 4 terminals and remove the terminals. Using a suitable tool (or with thumb and forefinger), apply pressure to the four snap-in hooks of the luminaire housing until the housing base releases from the latch.
- Remove the LED module with the diffuser from the holder. Install the replacement module. Please follow the installation instructions for the new LED module.
- A defective LED-module (silicone diffusor) must be replaced.
- Close the luminaire housing:
- Place the lower part of the housing on the snap-in hooks of the upper part of the housing and snap it into place with pressure. First tighten the four inner Torx screws (T20 max. 1.2 Nm), then the two outer Torx screws (T20 max. 0.35 Nm).
- Re-attach the terminals to the wires of the luminaire cable.
- Make the electrical connection to the terminals. Observe the correct configuration of the connecting cable. Connect the live conductor to the brown wire (L) and the neutral conductor to the blue wire (N).
- The two connecting terminals marked DA, DA are provided for digital control purposes.
- If these terminals are not assigned, the luminaire will work with full light output. Position the luminaire housing in a flat inclination angle over the fastening edge of the mounting plate and swing in.
- Align luminaire housing and tighten (max. 0.25 Nm) hexagon socket screw (wrench size 1.5).
Accessories · Wall panels
For this luminaire, optional arched wall panels made of metal are available in
3 finishes.
Wall panels are accessories and must be ordered separately.
Article number
Colour velvet white 13 341
Colour matt brass 13 342
Colour velvet black 13 343
Spares
LED power supply unit DEV-0305/700i
LED module 3000 K LED-1405/930
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>