BEGA 508224K3 Pendant Luminaire Indoor Instruction Manual

June 1, 2024
BEGA

BEGA 508224K3 Pendant Luminaire Indoor

BEGA-508224K3-Pendant-Luminaire-Indoor-product

FAQ

Frequently Asked Questions

  • Q: Can I install the luminaire myself?
    • A: Installation and commissioning should only be carried out by a qualified electrician to ensure safety and proper functionality.
  • Q: What is the power supply voltage for the LED unit?
    • A: The LED power supply unit operates at 220-240 V x 0/50-60 Hz DC 176-280 V.
  • Q: Is the luminaire suitable for outdoor use?
    • A: The product description does not mention outdoor suitability. It is recommended to check the manufacturer’s guidelines for specific use cases.

Dimensions

BEGA-508224K3-Pendant-Luminaire-Indoor-fig-1

Application

  • Pendant luminaire · indoor luminaire for free radiating and uniform light made of hand-blown opal glass, satin matt. Metal luminaire housing.

Product Description

  • Luminaire housing and canopy made of metal, finish Brass
  • Hand-blown opal glass, satin matt
  • Mounting plate with 2 fixing holes ø 4.5 mm · 138 mm spacing
  • Cable pendant · Sheath cable white 3 × with 1 steel wire
  • Overall length of luminaire approx. 2000 mm
  • Connection terminal
  • Earth conductor connection
  • Complies with flicker requirements in accordance with IEEE 1789, DIN IEC/TR 63158, DIN IEC/TR 61547-1
  • LED power supply unit inside canopy: 220-240 V 0/50-60 Hz
  • DC 176-280 V
  • During DC operation the LED power is reduced to 15 %
  • DALI-controllable
  • Number of DALI addresses: 1
  • A basic isolation exists between power cable and control line
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
  • Safety class I
  • – Safety mark
  • CE:  Conformity mark
  • This product contains light sources of energy efficiency class(es) D
  • Weight: 3.8 kg

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Specifications

Lamp

  • Module connected wattage 52.5 W
  • Luminaire connected wattage 58.5 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 40 °C

50 822.4 K3

  • Module designation 5x LED-0978/930
  • Colour temperature 3000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 7950 lm
  • Luminaire luminous flux 6250 lm
  • Luminaire luminous efficiency 106,8 lm / W

50 822.4 K4

  • Module designation 5x LED-0978/930
  • Colour temperature 4000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 8075 lm
  • Luminaire luminous flux 6348 lm
  • Luminaire luminous efficiency 108,5 lm / W

Installation

  • LED are high-quality electronic components!
  • Please avoid touching the light output opening of the LED directly during installation or relamping.
  • Release the adjusting knob and guide the canopy downward the luminaire power supply cable.
  • Unplug the earth conductor connection (plug contact).
  • Pass the power connecting cable through the cable entry in the mounting plate.
  • Fix the mounting plate with enclosed or any other suitable fixing material onto the mounting surface.
  • Make sure to use the gaskets supplied.
  • Make the earth conductor connection and the electrical connection to the terminals. Make the earth conductor connection to the canopy (plug contact).
  • For digital control please use the connecting terminal DA, DA.
  • In case this terminal is not used the luminaire will be operated at full light output.
  • Slide the canopy to the ceiling so it is centred by the mounting plate and tighten the adjusting knob.
  • Unscrew glass cover and lift it.
  • Place glass onto the glass support and adjust it centrically. Screw glass cover onto the glass.

Shortening of flex suspension

  • The flex suspension must only be shortened at the canopy end.
  • Remove the canopy cover.
  • Loosen set screw of the steel wire clamp and pull out steel wire.
  • Remove connection lines from power supply unit terminal.
  • Loosen screws of the cable strain relief.
  • Shorten cable to the desired length and strip the coating about 100 mm.
  • Strip coating of steel wire about 95 mm.
  • Strip the lines approx. 7 mm and tin them.
  • Tighten cable by using the cable strain relief.BEGA-508224K3-Pendant-Luminaire-Indoor-fig-5
  • Make earth connection and electrical connection to the power supply unit terminal.
  • Route the steel wire twice through the steel wire clamp and re-tighten the locking screw.

Maintenance And Replacement of the LED module

Cleaning · Maintenance

  • Clean luminaire regularly with solvent-free cleansers from dirt.

Replacement of the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire.
  • Please follow the installation instructions for the LED module.
  • Defective glass must be replaced.
  • Close the luminaire.

Spares

  • Spare glass 11 002 273 .0R G
  • LED power supply unit DEV-0315/1600i
  • LED module 3000 K LED-0978/930
  • LED module 4000 K LED-0978/940

BEGA Gantenbrink-Leuchten KG