BEGA 24 619 Wall Luminaire Instruction Manual
- May 15, 2024
- BEGA
Table of Contents
Wall luminaire
24619 Instructions for
use
Application
Wall luminaire with two-sided light output.
For illumination and design tasks in architecture.
The light directed downwards is intended to illuminate the wall and the
horizontal surface in front of it.
The light directed upwards is intended to illuminate the wall and ceiling
surfaces.
Product description
Luminaire made of aluminium alloy, aluminium and stainless steel BEGA Unidure
® coating technology
Colour graphite, silver or white Matt safety glass
Reflector surface made of pure aluminium Mounting plate with 2 fixing holes ø
5.4 mm · 70 x 125 mm spacing 2 screw cable glands with strain relief for
through-wiring power connecting cable ø 7–12 mm 1 screw cable gland closed at
the factory with a dummy plug
Connecting terminal 2.5@ with plug connection Earth conductor connection BEGA
Ultimate Driver® LED power supply unit 220-240 V x 0/50-60 Hz DC 176-264 V
DALI-controllable Number of DALI addresses: 1 Basic insulation is provided
between the mains and control cables BEGA Thermal Control® Temporary thermal
regulation to protect temperature-sensitive components without switching off
the luminaire Safety class I Protection class IP 65 Dust-tight and protection
against water jets Impact strength IK06 Protection against mechanical impacts
< 1 joule
– Safety mark
**** – Conformity mark
Weight: 4.4 kg
This product contains light sources of energy efficiency class(es) D
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Lamp
Module connected wattage | 35.4 W |
---|---|
Luminaire connected wattage | 39 W |
Rated temperature | ta = 25 °C |
Ambient temperature | ta max = 35 °C |
24 619 K3
Module designation | 2x LED-0800/830 |
---|---|
Colour temperature | 3000 K |
Colour rendering index | CRI > 80 |
Module luminous flux | 5960 lm |
Luminaire luminous flux | 1897 lm |
Luminaire luminous efficiency | 48,6 lm / W |
24 619 K4
Module designation | 2x LED-0800/840 |
---|---|
Colour temperature | 4000 K |
Colour rendering index | CRI > 80 |
Module luminous flux | 6120 lm |
Luminaire luminous flux | 1948 lm |
Luminaire luminous efficiency | 49,9 lm / W |
Lighting technology
Wall luminaire with narrow beam light distribution.
Half beam angle of the light distribution in both half spaces 14°.
Installation
Undo hexagon socket head screws (wrench size 3 mm) up to the stop and
disassemble the mounting plate.
Pass the power connecting cable through the cable entry in the mounting plate.
The installed black gasket insert is intended for cables ø < 10 mm.
For cables ø 10-12 mm the enclosed grey gasket insert must be used.
In case of through-wiring replace the factory installed dummy plug with the
enclosed corresponding gasket insert.
At the same time, use the enclosed synthetic cone-thrust collar between gasket
insert and thrust screw (wrench size 22 mm) (see sketch).
Fix the mounting plate with enclosed or any other suitable fixing material
onto the mounting surface.
Tighten screw cable gland.
Make earth conductor connection and electrical connection to the connecting
terminal (plug connection).
For digital control please use the connecting terminal DA, DA.
In case this terminal is not used the luminaire will be operated at full light
output.
Make sure that gasket is positioned correctly.
Push plug into coupler as far as it will go.
Place the luminaire onto the mounting plate and fix it.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced. Close the luminaire.
Spares
Shield inside | 16 006 367 |
---|---|
LED power supply unit | DEV-0270/1050i |
LED module 3000 K | LED-0800/830 |
LED module 4000 K | LED-0800/840 |
Reflector | 76 001 986 |
Gasket housing | 83 002 076 |
Gasket mounting box | 83 002 077 |
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden
info@bega.com
www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>