Application

Wall luminaire with two-sided light output.
For illumination and design tasks in architecture.
The light directed downwards is intended to illuminate the wall and the horizontal surface in front of it.
The light directed upwards is intended to illuminate the wall and ceiling surfaces.

Product description

Luminaire made of aluminium alloy, aluminium and stainless steel BEGA Unidure ® coating technology
Colour graphite, silver or white Matt safety glass
Reflector surface made of pure aluminium Mounting plate with 2 fixing holes ø 5.4 mm · 70 x 125 mm spacing 2 screw cable glands with strain relief for through-wiring power connecting cable ø 7–12 mm 1 screw cable gland closed at the factory with a dummy plug
Connecting terminal 2.5@ with plug connection Earth conductor connection BEGA Ultimate Driver®  LED power supply unit 220-240 V x 0/50-60 Hz DC 176-264 V DALI-controllable Number of DALI addresses: 1 Basic insulation is provided between the mains and control cables BEGA Thermal Control®  Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire Safety class I Protection class IP 65 Dust-tight and protection against water jets Impact strength IK06 Protection against mechanical impacts < 1 joule
  – Safety mark
**** – Conformity mark
Weight: 4.4 kg
This product contains light sources of energy efficiency class(es) D

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Lamp

Module connected wattage 35.4 W
Luminaire connected wattage 39 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 35 °C

24 619 K3

Module designation 2x LED-0800/830
Colour temperature 3000 K
Colour rendering index CRI > 80
Module luminous flux 5960 lm
Luminaire luminous flux 1897 lm
Luminaire luminous efficiency 48,6 lm / W

24 619 K4

Module designation 2x LED-0800/840
Colour temperature 4000 K
Colour rendering index CRI > 80
Module luminous flux 6120 lm
Luminaire luminous flux 1948 lm
Luminaire luminous efficiency 49,9 lm / W

Lighting technology
Wall luminaire with narrow beam light distribution.
Half beam angle of the light distribution in both half spaces 14°.

Installation

Undo hexagon socket head screws (wrench size 3 mm) up to the stop and disassemble the mounting plate.
Pass the power connecting cable through the cable entry in the mounting plate.
The installed black gasket insert is intended for cables ø < 10 mm.
For cables ø 10-12 mm the enclosed grey gasket insert must be used.
In case of through-wiring replace the factory installed dummy plug with the enclosed corresponding gasket insert.
At the same time, use the enclosed synthetic cone-thrust collar between gasket insert and thrust screw (wrench size 22 mm) (see sketch).

BEGA 24 619 Wall Luminaire - Screw

Fix the mounting plate with enclosed or any other suitable fixing material onto the mounting surface.
Tighten screw cable gland.
Make earth conductor connection and electrical connection to the connecting terminal (plug connection).
For digital control please use the connecting terminal DA, DA.
In case this terminal is not used the luminaire will be operated at full light output.
Make sure that gasket is positioned correctly.
Push plug into coupler as far as it will go.
Place the luminaire onto the mounting plate and fix it.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced. Close the luminaire.
Spares

Shield inside 16 006 367
LED power supply unit DEV-0270/1050i
LED module 3000 K LED-0800/830
LED module 4000 K LED-0800/840
Reflector 76 001 986
Gasket housing 83 002 076
Gasket mounting box 83 002 077

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden
[email protected]
www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BEGA User Manuals

Related Manuals