BEGA 23 250.6 Wall Luminaire For Indoor Use Instruction Manual

June 1, 2024
BEGA

BEGA 23 250.6 Wall Luminaire For Indoor Use

Specifications:

  • Lamp Module connected wattage: 7.6 W
  • Luminaire connected wattage: 8.8 W
  • Rated temperature: 25-40 °C
  • Ambient temperature: 25-40 °C
  • Module designation: 2x LED-0424/930, 2x LED-0424/940
  • Color temperature: 3000 K, 4000 K
  • Colour rendering index (CRI): > 90
  • Module luminous flux: 1260 lm, 1330 lm
  • Luminaire luminous flux: 912 lm, 962 lm
  • Luminaire luminous efficiency: 103.6 lm / W, 109.3 lm / W

Product Usage Instructions

Safety:
The installation and operation of this luminaire must comply with national safety regulations. Only a qualified electrician should perform the installation and commissioning to prevent damage due to improper use or installation.

Overvoltage Protection:
The electronic components in the luminaire are protected against overvoltage as per DIN EN 61547. For additional protection against transients, it is recommended to use separate overvoltage protection components available on the manufacturer’s website.

Installation:
Ensure a minimum distance of 250 mm between the removable cap and the wall for mounting and dismantling. Avoid direct contact with the light output opening of the LED during installation or relamping.

FAQ:

Q: Can I replace specific parts of the luminaire?
A: Yes, you can replace spare parts including spare glass, LED power supply unit, LED modules for both 3000 K and 4000 K, and gaskets. Refer to the provided part numbers for ordering replacements.

Wall luminaire for indoor use

Instructions for use

Application

  • Wall luminaire · indoor luminaire made of handblown opal glass and metal housing, for all lighting tasks in interior applications.
  • They are ideal for places where a soft and uniform lighting distribution is required.
  • Luminaire with a high protection class.

Product Description

  • Luminaire made of Aluminium, finish Colour velvet copper
  • Hand-blown opal glass
  • Two elongated mounting holes
  • Width 6 mm · 275 mm spacing
  • Insulating housing with cable entry for mains supply cable up to ø 10,5 mm,
  • max. 3 x 1,5@
  • Connection terminal 2.5@
  • Earth conductor connection
  • BEGA Ultimate Driver®
  • Complies with flicker requirements by IEEE 1789,
  • DIN IEC/TR 63158, DIN IEC/TR 61547-1
  • LED power supply unit
  • 220-240 V x 0/50-60 Hz
  • DC 176-264 V
  • BEGA Thermal Switch®
  • Temporary thermal shutdown to protect
  • temperature-sensitive components
  • Safety class I
  • Protection class IP 44
  • Protected against granular foreign bodies ≥ 1 mm and splash water
  • Impact strength IK02
  • Protection against mechanical impacts < 0.2 joule
  • – Safety mark
  • – Conformity mark
  • Weight: 1.7 kg
  • This product contains light sources of energy efficiency class(es) D

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

BEGA-23-250-6-Wall-Luminaire-For-Indoor-Use-FIG-
\(1\)

  • The electronic components installed in the luminaire are protected against overvoltage by DIN EN 61547.
  • To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

SPECIFICATION

Lamp

  • Module connected wattage 7.6 W
  • Luminaire connected wattage 8.8 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 40 °C

23 250.6 K3

  • Module designation 2x LED-0424/930
  • Colour temperature 3000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 1260 lm
  • Luminaire luminous flux 912 lm
  • Luminaire luminous efficiency 103,6 lm / W

23 250.6 K4

  • Module designation 2x LED-0424/940
  • Colour temperature 4000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 1330 lm
  • Luminaire luminous flux 962 lm
  • Luminaire luminous efficiency 109,3 lm / W

Installation

  • For mounting and dismantling please keep a minimum distance of 250 mm between the removable cap and the wall.
  • LEDs are high-quality electronic components!
  • Please avoid touching the light output opening of the LED directly during installation or relamping.

DIMENSION

BEGA-23-250-6-Wall-Luminaire-For-Indoor-Use-FIG- \(2\)

Open luminaire:

  • Loosen the knob, and remove the cap and glass.
  • Drill mounting holes into the mounting surface – spacing 275 mm.
  • For the mains supply connecting open the insulation housing – pull open – strip mains supply cable max. 15 mm and lead it into the insulation housing – see sketch.
  • Make earth conductor connection and electrical connection.
  • Connect both parts of the insulation housing until they audibly engage.
  • The outer coating of the cable has to be fully enclosed by the compression nipple.
  • Fix the luminaire with enclosed or any other suitable fixing material onto the mounting surface.
  • Place glass into the luminaire housing, close the luminaire with the cap, and screw in the knob into the cap.

Replacement of the LED module

  • The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
  • The light color and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
  • Disconnect the system.
  • Loosen the lateral knob, remove cap and take out the glass.
  • Please follow the installation instructions for the LED module.
  • The defective glass must be replaced.
  • Insert glass into luminaire housing, close luminaire with the cap and screw in knob into the cap.

Spares

  • Spare glass 11 002 946 .1R G
  • LED power supply unit DEV-0304/350
  • LED module 3000 K LED-0424/930
  • LED module 4000 K LED-0424/940
  • Gasket 83 001 179

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com  www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals