Product Usage Instructions

  1. Ensure that the KRIPOL product is properly connected to the power source.
  2. If there is no power, check the power outlet and make sure it is functioning correctly
  3. Inspect the power cord for any damage or loose connections. If found, replace or repair the cord accordingly.
  4. Verify that the KRIPOL product is turned on and the power indicator light is illuminated.
  5. If the power indicator light is not lit, press the power button to turn on the product.
  6. Check the user manual or product documentation for any specific troubleshooting steps related to your issue.
  7. If the issue persists, contact our customer support for further assistance. Provide them with the troubleshooting guide code 2022004-3 for reference.

Please note that if you are not qualified to perform electrical repairs, it is recommended to seek professional help rather than attempting to fix the issue yourself.

TROUBLESHOOTING

BENNTOP-B0C4YKH7DT-1500-Watt-Pure-Sine-Wave-Inverter-
FIG-1

  1. How to check whether the inverter is in good condition
    • Keep no load, and turn on the switch, the machine can be turned on normally (the green indicator light is on, and the LED shows the value), and the machine is intact.
    • Step A is normal, but it does not work. Follow the troubleshooting points to troubleshoot one by one.
    • The machine is burnt out {beeps as soon as it is turned on, the red indicator light is always on}. This performance needs to eliminate the fault points of undervoltage, overvoltage, and overtemperature in advance.
    • The machine is burnt out {there is no response when the machine is turned on, the indicator light does not light up, the LED does not display, and the machine does not beep). This performance needs to eliminate the fault point of the reverse connection in advance.
  2. There is a certain unqualified rate (<0.005) when the product leaves the factory, and some machine faults are not included in the above exclusion points. Please contact the technical team via email to resolve this.
  3. KRIPOL’s factory is located in China, and it takes a period for shipping to the relevant sales country. During this period, there may be some uncontrollable damage to the equipment, and failure performance other than the above may occur. Please contact the technical team via email to resolve this.

QUESTION AND ANSWER

There is no problem with DC and load, but still can not be used?
Check whether the battery capacity matches the load; check whether the connecting cable is too thin;

My remote control cannot be used?
Check whether the remote control distance is within 80M; if the indicator light is no longer on, please contact customer service for replacement.

My cooler keeps not working.
The internal temperature of the machine has not reached 45°C; the ambient temperature of the machine is too low.

Sparks when connecting the battery?
It is a normal phenomenon, please use the provided cable, we have configured enough capacity.

Does the cable heat up when the inverter is working?
It is a normal phenomenon. The cables provided are configured with different capacities according to different specifications, please feel free to use them.

Is there any deviation in the LED display value?
It is a normal phenomenon. When the inverter is working, there is a certain time difference and deviation between the LED display and the circuit board.

Does it drain my battery at zero load?
Almost no consumption, all models do not exceed 1A.

How to calculate the battery capacity my inverter needs?
Power=voltagebattery capacity0.8=VAH0.8. Please calculate according to your load.

How long will my battery power my device?
Time=battery voltagebattery capacity0.72/load power=VAH0.72/W. Please calculate according to your battery data.

GUARANTEE
The product warranty period is one year from the date of purchase. From the date of your purchase, if you have any questions, we provide free consultation and solutions.

BENAWAY168@outlook.com

TECHNICAL PARAMETER

BENNTOP-B0C4YKH7DT-1500-Watt-Pure-Sine-Wave-Inverter-
FIG-2

PROTECTION TYPES

-B0C4YKH7DT-1500-Watt-Pure-Sine-Wave-Inverter-FIG-4

CAUTION

  1. Choose a cool, clean, dry, and well-ventilated place. Close the battery bank to prevent the voltage drop in the battery cables. Make enough room to access the AC receptacles and DC wiring terminal and connections.
  2. Preventing DC input Over voltage. Do not connect the inverter to a battery system with a voltage higher than the rated battery input voltage.
  3. Do not use a solar panel or solar charge controller to connect to the inverter. Only connect the inverter with well well-charged battery or battery bank with stable voltage.
  4. Be careful using the red (positive) and black (negative) cables in the package to keep them connected properly. Use qualified cables.
  5. Overvoltage, undervoltage, high temperature, and other wrong uses will cause the inverter to buzz, which is a normal phenomenon, not a problem with the machine itself. If the beeping still occurs after the correct operation, please check the troubleshooting table (2022004-3) and contact the technical team in time.

2022004-2

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals