BEGA 51 271.6 Indoor Use Pendant Luminaire Instruction Manual

May 15, 2024
BEGA

**BEGA 51 271.6 Indoor Use Pendant Luminaire Instruction Manual

**

Instructions for use

Application
Pendant luminaire – Indoor luminaire with ring-shaped light source for unshielded and uniform light, light-diffusing silicone diffuser and metal ring.
As single luminaires or in arrangements, they are creative lighting design solutions for interior design.

Lamp
Module connected wattage 34.7 W
Luminaire connected wattage 39 W
Rated temperature ta=25 °C
Ambient temperature ta max=45 °C

51 271.6K3
Module designation LED -1399/930
Color temperature 3000 K
Color rendering index CRI > 90
Module luminous flux 5400 elm
Luminaire luminous flux 3747 elm
Luminaire luminous efficiency 96,1 lm/W

Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Product description
Luminaire housing made of synthetic material,
finish color velvet white
Ring and round inlay made of metal, finish color matt copper
Diffusor made of translucent ageing-resistant silicone
Synthetic canopy, finish color matt copper
Round inlay made of metal in the canopy, finish color velvet white
Mounting plate with 2 fixing
holes o 4.5mm 86mm spacing
Cable pendant Sheath cable white 2 x 0,75 Synthetic 2-piece line connector (clamp part with screw cap) for braided coaxial cables With internal pressure spring and contact wire Overall length of luminaire approx. 2000 mm Connecting terminals 1,5
Earth conductor terminal
LED power supply unit inside canopy
220-240V0/50-60 Hz
DC 196-250 V
DALI-controllable
Number of DALI addresses: 1
A basic isolation exists between power cable and control line
BEGA Thermal Control
Temporary thermal regulation to protect
temperature-sensitive components without switching off the luminaire
Safety class I
CE-Conformity mark
This product contains light sources of energy
efficiency class(es) D
Weight: 1.2 kg

Prior to installation, please note:
The canopy is not equipped with through wiring of the power connecting cable by the manufacturer.
However, if suitable installation
components are used, through-wiring may be carried out by the customer.

Installation
LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or revamping.
Remove the pendant luminaire and canopy from the packaging.
Detach the canopy downwards from the mounting plate against the magnetic resistance.
Push the canopy downward on the luminaire cable.
Place the pendant luminaire on the mounting plate and make markings for the mounting holes on the ceiling.

NOTE : If multiple pendant luminaires are to be installed in a row, the arrows imprinted on the mounting plate are helpful for precise orientation in a line.
Pass the power connecting cable through the cable entry in the mounting plate.
Fasten the mounting plate with the supplied fastening material or other suitable fastening material to the installation surface.
Establish the earth conductor connection on the lateral earthing screw (1) of the bracket of the mounting plate.
Make the electrical connection (L) and (N) via the power supply unit terminals. Observe the correct configuration of the connecting cable. For digital control please use the connecting terminals DA, DA at the power supply unit .
In case these connectors are not used the luminaire will be operated at full light output. Slide the canopy towards the ceiling until it is held securely in place by the holding magnets of the mounting plate.
For fine adjustments to the pendant luminaire, the canopy can be rotated by +/- 10° around the vertical canopy axis in its final position.

Trimming the cable pendant
The cable may only be trimmed above in the canopy.
Disconnect the system from the mains. Detach the canopy downwards from the mounting plate against the magnetic resistance.
Push the canopy downward on the luminaire cable

IMPORTANT : Ensure the pendant luminaire is held firmly in place when setting the desired suspension height!

Remove the connecting wires of the luminaire cable red and black from the power supply unit.
Unscrew the coaxial cable connector and remove the luminaire cable from the lower part of the connector.
To adjust the suspension height, loosen the locking screws (Torn T10) of the strain relievers on both luminaire cables, adjust the cable length and tighten the locking screws again. Shorten the excess length on the non-live luminaire cable so that an overhang of 10- 20 mm remains above the strain relief. Shorten the excess luminaire cable on the live luminaire cable so that a projection of 140- 150 mm remains above the strain reliever. Please consider these 140-150 mm when cutting the cable to the required length. Strip 60 mm to max. 80 mm of the insulation from the luminaire cable at the top end.
Trimming the cable pendant

Installing the coaxial cable connector
Guide the stripped cable end (A) into the lower part of the connector (clamp part) (B) until it stops.
Hold the luminaire cable below the lower part of the connector.
Carefully push together the coaxial mesh of the
stripped section with two fingers of your other
hand bit by bit directly above the connector thread, until the black wire is laid bare. Make sure that the coaxial mesh is inserted into the recess on the lower part of the connector see diagram (C).
Guide the black wire through the opening in the middle of the screw cap.
Make sure that the red wire is correctly positioned in the cap with the internal pressure spring. Screw the closing cap (top part of the connector) in clock-wise direction onto the clamp part (lower part of the connector) until it stops (D).
Strip back 7-8 mm of the black wire (E). Connect red wire to “+” and black wire to “-” on the marked power supply unit terminals.

Slide the canopy towards the ceiling until it is held securely in place by the holding magnets of the mounting plate.

Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.

Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light color and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
Disconnect the system from the power supply.
Replacing the LED module

Release both of the inserted metal discs of the luminaire housing from the housing groove by applying slight pressure on the upper edge, and remove them against the magnetic force. Disconnect the two-pin LED plug connector.
LED plug connector.

To replace the LED module with diffuser, it is necessary to open the round luminaire housing Hold the pendant luminaire by the luminaire housing and, using a suitable tool, apply pressure to the three snap-in hooks of the luminaire housing until the housing cover releases from the latch.
Remove the LED module with the diffuser from
the holder. Install the replacement module. Please follow the installation instructions for the new LED module.
A defective luminaire cover must be replaced. Reconnect the two-pin LED plug connector. Make sure that both luminaire cables are correctly positioned in the cable routing of the luminaire housing.
Place the housing cover on the lower part of the housing with the snap-in hook and snap it into place by applying pressure.
Reinsert the previously removed metal discs into the magnetic housing recesses on both sides.

Spares
LED power supply unit DEV -0305/700i
LED module 3000 K with diffusor 65 002 232 K3
Round blank (inlay) 72 004 054B4

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals