BEGA 85053K3 Unshielded Garden and Path Luminaire
Product Information
Specifications:
- Unshielded garden and path luminaire with rotationally symmetrical light distribution
- Integrated passive infrared motion and light sensor
- Controlled via Bluetooth using a smartphone or tablet with the BEGA Smart app
- Lamp Module connected wattage: 3.9 W
- Luminaire connected wattage: 5.4 W
- Colour temperature options: 3000 K, 4000 K
- Colour rendering index (CRI): > 80
- Luminous flux range: 750 lm to 770 lm
- Luminous efficiency range: 85.7 lm/W to 88 lm/W
- Recommended light point interval: 7 m
Product Usage Instructions
Safety:
The installation and operation of this luminaire must comply with national
safety regulations. Only a qualified electrician should carry out installation
and commissioning. The manufacturer is not liable for damage due to improper
use or installation. Any modifications made to the luminaire should be done by
authorized personnel.
Installation:
- Avoid direct contact with the LED light output during installation or relamping.
- Securely close the connection box after installation.
- Align and tighten the bollard tube on the anchorage unit evenly.
- Securely screw the glass with the gasket into the luminaire housing ensuring correct gasket placement.
Commissioning:
Connect the power supply to commission the luminaire. The brightness sensor
may take up to 10 minutes to calibrate after power activation. Factory
settings include Motion and Light mode, high motion sensitivity, 5-minute
shut-down delay, and a brightness threshold of approximately 50 lx.
Frequently Asked Questions (FAQ):
-
Q: How do I change the settings of the luminaire?
A: The settings can be adjusted via the BEGA Smart app on your smartphone or tablet connected via Bluetooth. -
Q: What should I do if the luminaire is not functioning properly?
A: Check the power supply, ensure proper installation following safety guidelines, and refer to the user manual for troubleshooting steps. -
Q: Can I install this luminaire in areas prone to vandalism?
A: This luminaire is suitable for areas with no risk of vandalism due to its design and integrated sensors.
Application
Unshielded garden and path luminaire with rotationally symmetrical light
distribution. Suitable for private and public areas in which there is no risk
of vandalism.
The integrated passive infrared motion and light sensor responds to heat
emission in the dark and activates in case of human or animal movement in the
vicinity of the luminaire. Configuration is done via Bluetooth using
smartphone or tablet and the free BEGA Smart app.
Lamp
- Module connected wattage 3.9 W
- Luminaire connected wattage 5.4 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 50 °C
85 053 K3
- Module designation LED-0265/830
- Colour temperature 3000 K
- Colour rendering index CRI > 80
- Module luminous flux 750 lm
- Luminaire luminous flux 463 lm
- Luminaire luminous efficiency 85,7 lm / W
85 053 K4
- Module designation LED-0265/840
- Colour temperature 4000 K
- Colour rendering index CRI > 80
- Module luminous flux 770 lm
- Luminaire luminous flux 475 lm
- Luminaire luminous efficiency 88 lm / W
Lighting technology
Recommended light point interval 7 m
Product Description
- Luminaire made of cast aluminium, aluminium and stainless steel
- BEGA Unidure® coating technology
- Colour graphite or silver
- Luminaire with mounting base made of hot-dip galvanised steel according to EN ISO 1461 for bolting onto a foundation provided by the customer or on other paved surfaces such as terraces and paving stones
- Base plate with 3 fixing holes ø 9 mm · Pitch 120° · Pitch circle ø 65 mm Mounting bracket with connection box for through-wiring of up to 3 x 2,5 mm²
- Passive infrared motion sensor (PIR)
- Range up to 12 m
- Opening angle 120°–150°
- Decals for reducing the detection range are provided
- Minimum temperature difference between moving object and environment 4 °C
- Object speed ideally 1 m/s
- Adjustable sensitivity of the motion sensor (inertia)
- Shut-down delay adjustable between 5 s and 240 min
- Light sensor: adjustable value range from darkness (ca. 0 lx) to approaching dusk (approx. 150 lx)
- Fixed pre-set hysteresis for suppression of undesired switching operations in luminaires during rapid brightness fluctuations Transmission frequency range: 2400-2483.5 MHz
- Maximum transmission output: 10 mW Luminaire switchable via relay output (on/off) integrated in the sensor module
- Relay contact with a switching capacity of 2300 W · 10 A
- Please note the starting current of the switching loads – max. 100 A
- Ambient temperature: -25°C to +55°C Luminaire power supply unit
- Starting current: 7 A (112 µs)
- 220-240 V 50-60 Hz
- BEGA Thermal Switch®
- Temporary thermal shutdown to protect temperature-sensitive components
- Safety class I
- Protection class IP 65
- Dust-tight and protection against water jets Impact strength IK04
- Protection against mechanical
- impacts < 0.5 joule
- – Conformity mark
- This product contains light sources of energy efficiency class(es) C
Safety
- The installation and operation of this luminaire are subject to national safety regulations.
- Installation and commissioning may only be carried out by a qualified electrician.
- The manufacturer accepts no liability for damage caused by improper use or installation.
- If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547. To achieve additional protection
against e. g. transients, etc. we recommend separate overvoltage protection
components.
You can find them on our website at www.bega.com.
The ideal protection of all electronic components installed in the luminaires
is achieved by using bounce-free switching contacts such as an electronic
relay (solid-state relay), e.g. BEGA 71 320.
Installation
- LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
- The base of the luminaire must not be below top edge of the ground surface.
- A cable length of 400 mm above the ground surface is required for the electrical connection of the luminaire.
- Remove the mounting base from the luminaire by undoing the screws at the base of the luminaire.
- Lead underground cable from below in the mounting base.
- Fix the mounting base with enclosed or any other suitable fixing material onto the mounting surface.
- Open the connection box.
- Lead the luminaire wiring and mains supply cable into the connection box.
- Make the earth conductor connection and the electrical connection.
- Note the correct configuration of the terminals (see drawing).
- Close the connection box.
- Lead the bollard tube on the anchorage unit and align.
- Tighten the screws evenly.
- Screw the glass with the gasket into the luminaire housing and tighten firmly.
- Make sure that the glass gasket is seated correctly (see sketch).
Commissioning
The power supply must be connected for the commissioning of the luminaire. The brightness sensor will need up to 10 minutes after activation of the power supply to correctly calibrate the brightness value. Once installed, the luminaire can be operated immediately in its factory settings; configuration via smartphone will not be required.
The factory settings as are follows:
- Mode: Motion and light
- Motion sensitivity: 100 % (high sensitivity)
- Shut-down delay: 5 minutes
- Brightness threshold: 32 (approx. 50 lx)
Alternatively, the integrated PIR motion and light sensor can be configured
via smartphone or tablet using the free BEGA Smart app.
The default values can be reinstated at any time via the BEGA Smart app
.
Download the app for Android or iOS and add the luminaire as your starting point. The Data matrix code needed for commissioning is provided on the sensor housing, the luminaire head and on the connecting cable of the luminaire. Please retain the additional enclosed QR codes in your customer documentation (e.g. Instructions for use, at the top of Page 1). Select the “Share access” function in the BEGA Tool app enables parameterisation or control via additional smartphones. function in the BEGA Tool app if you want to use a different or additional smartphone for the configuration of the integrated sensor module or controlling the luminaire head.
Please note: The integrated light sensor operates with a time delay to prevent responses to short-term brightness fluctuations in the environment of the luminaire. Delay time approx. 1 to 3 min. A manual darkening of the sensor will therefore not result in an immediate response.
Once successfully commissioned, the sensor can be configured in the BEGA Smart app.
The following 3 states can be set:
- “Illumination during movement”
- State that is activated for the configured shut-down delay period when movement is detected.
If the light sensor is also active, motion detection is only activated if the light sensor detects the environmental brightness to be below the configured threshold. After the shut-down delay period, the state “Illumination at specific environmental brightness” is executed. If the light sensor is deactivated, the state is activated independently of the environmental brightness if movement is detected. After the configured shut-down delay period, “Illumination in default state” is activated.
- “Illumination at specific environmental brightness”
- State which is activated when the environmental brightness falls below the configured threshold.
- “Illumination in default state”
- State which is activated when the environmental brightness has exceeded the configured threshold value and no movement is detected.
The motion sensor as well as the light sensor can be switched off individually. This reduces the respective states. The shut-down delay is freely adjustable up to 4 hours. The current measured environmental brightness can be queried. This is shown by the grey sun symbol. The threshold value can also be set there. All other components in the BEGA Smart System can be allocated and configured to these states. Depending on the additionally used BEGA Smart components, different light levels, light colours or colour temperatures can be set. The luminaire head of the bollard can only be switched on or off.
Range / Detection area
The specifications for the range and detection area of the PIR motion sensor
are reference values. Detection range is 120° to 150° at a depth of 5 m up to
max. 12 m, depending on motion direction (see illustration). Too minor
temperature difference between the moving object and the ambient temperature
can influence the detection range. Local conditions and external heat sources
may affect both the range and the detection area.
Reducing the detection range
Use the decals provided to reduce the vertical detection area of the sensor.
The smaller decals reduce the detection area by around one-third, the larger
ones by around one-half (see sketch). Clean the sensor with a soft cloth
soaked in alcohol before applying the decals. Ensure exact positioning when
attaching the decals.
Dimension
Circuit variants
Forwarding of the switching signal to additional luminaires can be achieved via the relay contact L’ (see circuit diagram 1).
Circuit diagram 1:
The first sensor of a luminaire controls a group of luminaires, while the
second luminaire sensor controls another group.
Circuit diagram 2:
Sensors of multiple luminaires control the same luminaire group. All
luminaires in the group will be switched on as soon as one of the sensors
detects movement. It is important to note that all sensors within one group
are fed via the same phase.
Circuit diagram 3:
Apart from wired control, the sensor also offers the option of wireless
communication with Zigbee lamps or other BEGA Smart actuators, e.g. 71149
Reset to factory settings
The luminaire must be switched off five times within 30 seconds for at least 2
seconds each time to manually reset it to factory settings (see sketch).
The luminaire can further more be reset to the factory settings via the BEGA
Smart app. The reset is confirmed with five flashes of the luminaire. The
smartphone will be disconnected.
Status display
- Status LED flashes green:
- The luminaire is searching for a nearby network and is ready for configuration.
- The status LED goes out if no start-up procedure is executed within 180 seconds.
- Status LED flashes green and the luminaire is already configured:
- The luminaire opens the network for new participants in the BEGA Smart System.
EU Declaration of Conformity
BEGA Gantenbrink-Leuchten KG here by declares that the radio system type 85
053 complies with Directive 2014/53/EU (RED). The complete text of the EU
Declaration of Conformity is available at the following Internet address:
https://www.bega.com/conf/de/85053
Cleaning & Maintenance
- Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
- Do not use high pressure cleaners.
Replacing the LED module
- The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
- The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
- The module can be replaced by qualified persons using standard tools.
- Disconnect the system and open the luminaire.
- Please follow the installation instructions for the LED module.
- Inspect and, if necessary, replace the luminaire gaskets.
- Defective glass must be replaced.
- Close the luminaire.
Spares
- LED power supply unit DEV-0303/350 /61 002 011
- LED module 3000 K LED-0265/830
- LED module 4000 K LED-0265/840
- Glass graphite 75 005 207
- Glass silver 75 005 208
- PIR and light sensor graphite 75 005 857
- PIR and light sensor silver 75 005 859
- Gasket glass 83 001 996