BLAUPUNKT P3PM2T2 EV Portable Charger User Manual

October 30, 2023
Blaupunkt

BLAUPUNKT P3PM2T2 EV Portable Charger User Manual
BLAUPUNKT P3PM2T2 EV Portable Charger

Introduction to the Portable EV Charger ( Mode 2 )

CAUTION

  • Use the power source with external upstream Circuit Breaker.
  • Make sure the charger is used in a safe, secure place and well out of the reach of young children or pets.
  • Please use the charger in a dry, well ventilated and secure place. Keep weel out of reach of young children or pets. Avoid water pouring directly onto the power plug.
  • Do not open the enclosure while charging or with the power on.
  • Do not maliciously damage the product.

Introduction to the Portable EV Charger ( Mode 2 )
Introduction to the Portable

Specifications

Model Type Length Voltage Current Type
P1PM2T2 Single-phase 8m 200-250V 8/10/13/16A T2
P1PM2T1 Single-phase 8m 200-250V 8/10/13/16A T1
P1PM2T2C Single-phase 8m 200-250V 8/10/13/16A T2
P3PM2T2 Three-phase 8m 380-450V 8/10/13/16A T2
P1PM2T2BS Single-phase 8m 200~250V 8/10/13A T2
P1PM2T1BS Single-phase 8m 200~250V 8/10/13A T1

Explanation of the operating display and technical parameters

Model: P3PM2T2
Explanation of the operating

Explanation of the operating display

| Power light
---|---
| Charge lamp
| Trouble lamp
| Current switch button
| Charging time
| Temperature
| PE Detection (Earthing Detection)
405V| Voltage
| Power
| Rated current
| Constant current
| Electricity consumption
| Time function button
| The upstream PE has not been detected and the charging cannot be started.

**Control box:


**

Technical Parameters

Dimensions (L ×W × H) 260 × 100 × 72.5 mm
Weight 3Phase: 3.35 kg
Protection Degree ( Control box ) IP65
Operating Temperature -30°C to +50°C

Explanation of the ”  ” and ” ” symbol

Users must check the PE detection mark ” ****” on the display before each use. (PE meaning protective conductor)

  1. If the Mark ” **” is displayed on the screen, it indicates that the charger shall verify the presence of the upstream PE, and the charging process will only begin when the upstream PE is present.
    ATTENTION: if the mark ” **” appears, it means that the upstream PE has not been detected and the charging cannot be started.

  2. If the Mark ” ****” is NOT displayed on the screen, it indicates that the charger has no function to verify the presence of the upstream PE, and can be charged whether or not the PE can be detected

ATTENTION: It is strongly recommended that users charge under condition

  1. Condition 2 has certain security risks due to the absence of PE. So Condition 2 should only be used under the premise that users can ensure safety and in special circumstances where PE does not exist in the power system.

Deactivate PE Detection : Press “Amps + Time” for 4s together.
Reactivate PE Detection: Press “Amps + Time” for 4s together.

Use of the charger – start charging

Start Charging

Step Illustration Operation
1. ![Start Charging](https://manuals.plus/wp-
content/uploads/2023/06/Screenshot_17-360.jpg) Insert the plug into the

correct power supply socket.
2.| Start Charging| Remove the protective cap and fully insert the charging connec t or int o the E V charging port.
3.| Start Charging| Start charging

DANGER

Do not use product if it appears to be damaged or the cable is broken. Do not disassemble or assemble the connector and change the internal parts Do not clean the products using chemicals or cleaning the EV car while charging

Stop Charging

Step Illustration Operation
1 ![Stop Charging](https://manuals.plus/wp-

content/uploads/2023/06/Screenshot_22-246.jpg)Stop
Charging| Disconnect the plug from the power supply socket.
2| | Disconnect the charging connector from the EV car.
3| | Close the protective shell of EV charging port,then cover the protective cap of the charging connector.
4| Stop Charging| Put the portable charger into the bag.

Display Light Status

Display Light Status

Indicator Light| Status| Indicator Light| Status| Indicator Light| Status
---|---|---|---|---|---
| Off| | Blink| | On
| Off| | Blink| | On
| Off| | Blink| | On

Operation:

1| Power Off| | |
---|---|---|---|---
2| Check| | |
3| Standby| | |
4| Connected| | |
5| Charging| | |
6| Charge Complete| | |

Troubleshooting:

1| CP Error| | |
---|---|---|---|---
2| Relay Error| | |
3| Over/Under Voltage| | |
4| Over current protection| | |
5| Electric leakage protection| | |
6| No ground connection| | |
7| Temperature warning| | |
8| Persistent high temperature| | |

Function: Switch Current

Switch Current:

CAUTION

In order to switch charging current, Please make sure the power plug is firmly inserted into the socket and plug for the EV vehicle is disconnected.

Step

| Illustration| Statu
---|---|---
1.Insert the plug into the correct power supply socket.| Switch
Current| Ready
Switch Current
2.Press the “Amps” switch button for 2 seconds| Switch
Current| Enter setting the switch current mode
3.Continue to press the button briefly.The current| Switch
Current| Setting the current of
will be changed. ( switch between 8-10-13-16A )| Switch
Current| User’s request
4.Press the button for 2s again.| | Setting successfully

Function: Timer function

Timer function:

CAUTION

In order to switch charging current, Please make sure the power plug is firmly inserted into the socket and the plug for EV vehicle is disconnected.

Step Illustration Statu
1.Insert the plug into the correct power supply socket. ![Timer

function](https://manuals.plus/wp- content/uploads/2023/06/Screenshot_37-66.jpg)| Ready
Timer function
2.Press the “Time” switch button for 2 seconds.| Timer
function| Enter setting the delay time mode
3.Continue to press the button briefly. The time will be changed.( Switch between 1/2/4/6/8/10H )| Timer function| Setting the delay time of User ’ s request
4.Press the button for 2s again| | Setting successfully

Please complete setting within 4 seconds at each step, otherwise the feature setting will fail.

Notice:

In case you want to cancel the timer setting – you can use one of the two options below:

  1. Directly to disconnect the plug from the outlet socket.
  2. Press the Time button for 5s.

EVSE