Easy-Link – Installation Instructions, LED Cabinet Luminaires Models EL
Please read all instructions prior to installation and keep for future reference!
- Product should be installed by a qualified electrician.
- Prior to installation ensure power is off at fuse box to prevent electrical shock.
- Use only with Class 2 power unit. Utiliser seulement avec Classe 2 unite d’alimentation electrique.
- Suitable for Damp Locations. Convient Aux Emplacements Humides.
- For under-cabinet or shelf mount.
- Conforms to UL STD 2108. Certified to CSA STD C22.2 No.250.
Easy-Link – Installation Instructions, LED Cabinet Luminaires Models EL
Please read all instructions prior to installation and keep for future reference!
- Product should be installed by a qualified electrician.
- Prior to installation ensure power is off at fuse box to prevent electrical shock.
- Use only with Class 2 power unit. Utiliser seulement avec Classe 2 unite d’alimentation electrique.
- Suitable for Damp Locations. Convient Aux Emplacements Humides.
- For under-cabinet or shelf mount.
- Conforms to UL STD 2108. Certified to CSA STD C22.2 No.250.0.
1.1 Determine the location of where the fixture(s) will be installed. Lay the
fixture(s) on the surface, and make reference marks for the mounting brackets.
Make marks 4” from each end of the fixture(s).
1.2 Lay the mounting bracket onto the mark points and secure using the
provided hardware
2.1 Snap fixture into the brackets to secure in place
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATIONS WITHOUT NOTICE
Please read all instructions prior to installation and keep for future reference!
- Product should be installed by a qualified electrician.
- Prior to installation ensure power is off at fuse box to prevent electrical shock.
- Use only with Class 2 power unit. Utiliser seulement avec Classe 2 unite d’alimentation electrique.
- Suitable for Damp Locations. Convient Aux Emplacements Humides.
- For under-cabinet or shelf mount.
- Conforms to UL STD 2108. Certified to CSA STD C22.2 No.250.0.
Sensor/Switch Installation (only follow the direction to your perticular model)
4.1 Carefully, remove the 4 screws from the sensor cover.
4.2 Run & connect a 120V AC conduit to the sensor, and secure (lock nut not
shown for clarity in diagram).
4.3 Connect the white (neutral) & black (hot) sensor wires to the white &
black power wires (120VAC). Ground wire in accordance with local electrical
codes. Secure cover back on.
4.4 Program sensor reference page 4
1 Carefully, remove the 4 screws from the on/off switch cover.
4.2 Run & connect a 120V AC conduit to the on/off switch and secure (lock nut
not shown for clarity in diagram).
4.3 Connect the white (neutral) & black (hot) on/off switch wires to the white
& black power wires (120VAC). Ground wire in accordance with local electrical
codes. Secure cover back on
4.1 Connect the power cord (120V AC)
4.2 Program sensor reference page 4
4.1 Connect the power cord (120V AC)
Please read all instructions prior to installation and keep for future reference!
- Product should be installed by a qualified electrician.
- Prior to installation ensure power is off at fuse box to prevent electrical shock.
- Use only with Class 2 power unit. Utiliser seulement avec Classe 2 unite d’alimentation electrique.
- Suitable for Damp Locations. Convient Aux Emplacements Humides.
- For under-cabinet or shelf mount.
- Conforms to UL STD 2108. Certified to CSA STD C22.2 No.250.0.
Sensor/Switch Programming Instructions
PROGRAMMING INSTRUCTIONS—-Please read all 3 steps before programming
- Enter a programming function by pressing button the number of times as the desired function number from the tables below (e.g., press twice for function 2, occupancy time delay).
- LED will flash back the selected function’s current setting (e.g., 5 flashes for 10 minute time delay). To change setting, proceed to step 3 before flash back sequence repeats 3 times. To exit the current function or to change to a different function, wait for sequence to repeat 3 times then return to step 1.
- Press button the number of times indicated in the particular function’s detailed table for the NEW desired setting (e.g., press 3 times for 5 min). As confirmation of setting change,LED flashes back the NEW setting 3 times before exiting.
PROGRAMING FUNCTIONS| STD
UNIT
---|---
2| Occupancy Mode &100 hr Burn-In| .
4| Test Mode ON Time| .
10| Minimum ON Time| .
14| Lamp Information| .
DETAILED FUNCTION TABLES
2 = Occupancy Time Delay
1| 30 sec| 4| 7.5 min| 7| 15.0 min
2| 2.5 min| 5| 10.0 min| 8| 17.5 min
3| 5.0 min| 6| 12.5 min| 9| 20.0 min
4 = Test Mode 1100hr Burn-In/ Auto Set-Point
1| Normal•| 4| Run Auto Set-Point
2| Run 100 hr Burn-In| 5| Blink back Set-Point2
3| Run 100 hr then Auto-Setpoint| 6| Test Mode 3
2 The LED will blink back the ten’s digit, then pause, then blink back
the one’s digit. For a “Oft the LED will blink very rapidly. The sequence
is repeated 3 times.
3Test Mode will disable Minimum On Time, set Occupancy Time Delay
to 30 sec, and shorten all photocell transitions and dimming rates.
Mode will expire after 1 0 min or if function 4 is set back to Normal.
10 = Minimum On Time
10| 0 min| 3| 30 min| 5| 60 min
2| 15 min| 4| 45 min|
14 = Lamp Information
1| Enable Lamp Maximizer+
2| Disable Lamp Maximizer+•
3| Total Switches/ 1000 ‘
4| Total nme On (khrs)’
5| Reset Total Switch and Total Time On Statistics
6| Reset LampMaximizer+ Value
4 The LED will blink back a two digit value; the first digit, then pause,
then blink back the second digit. For a “o· the LED will blink rapidly
- DEFAULT SETTING
** SPECIAL DEFAULT SETTING FOR -ADC, -D UNITS
***- SPECIAL DEFAULT SETTING FOR CM(R)B 6, CM(R)B 50,
CM(R) 6, RM(R) 6, RM(R) SO, SB(R) 6, & SB(R) SO SERIES UNITS
FUNCTION DEFINITIONS
2 OCCUPANCY TIME DELAY
The length of time an occupancy sensor will keep the lights on and at full
bright after it last detects occupancy (assuming minimum on time has been met)
4 100 HOUR BURN-IN I AUTO SET-POINT
TEST MODE
Disables Minimum On Time, sets Occupancy Time Delay to 30 sec,and shortens
all photocell transition and dimming rates.Mode will expire after 10 min or if
function 4is set back to Normal.
100 HOUR BURN-IN
Overrides relay on and/or dimming output to full bright (typically for lamp
seasoning)
AUTO SET-POINT
Photocell calibration procedure for detecting optimum lighting control level
10 MINIMUM ON TIME
The length of time required for lamps to be on in order to prevent all short cycling that shortens lamp life.iIf occupancy time delay expires prior to minimum on time being satisfied, the lamps will remain on until time has been met.
14 LAMP INFORMATION
LAMPMAXIMIXER+ (Enable/Disable)
Advanced operating mode where occupancy time delay adjustments are automatically made every two weeks. The time delay is adjusted according to an algorithm that determines the optimum time delay in order to maximize both lamp life and energy savings.
TOTAL SWITCHES
The current count (in 1 OO0’s) of the number of off to on cycles since
sensor installation (or since count was manually reset)
TOTAL RUN-TIME
The current elapsed time (in 1000’s of hrs) a controlled lamp has been on
since sensor was installed (or since count was manually reset)
RESET LAMPMAXIMIZER+
Method of clearing the sensor’s historical occupancy information such if a sensor is phycially moved.only new occupancy information will infuence lampmaximizer+result
NOTE:
For information on additional advanced settings, including resetting unit to
factory defaults, contact:
technical support
224-333-6033