luminii BA42WET Linear LED Strip Installation Guide

May 15, 2024
luminii

luminii BA42WET Linear LED Strip

luminii-BA42WET-Linear-LED-Strip-PRODUCT

Product Information

  • Specifications:
    • Model: BA42WET
    • Installation: Wet Locations, Under-Cabinet or Shelf Mount
    • Standards: UL STD 2108, CSA STD C22.2 No.250.0

Product Usage Instructions

  • Installation:
    • The product should be installed by a qualified electrician following these steps:
    • Ensure power is off at the fuse box before installation to prevent electrical shock.
    • Use only with a Class 2 power unit.
    • Mount the product on a suitable wet location surface.
  • Testing Before Installation:
    • Always test the BA42WET strip operation before installing it by connecting it to a power supply to ensure it works properly and has not been damaged during shipping.
  • Shortening the Strip:
    • If the length of the strip needs to be shortened:
    • Cut the LED strip between the solder pads from the end with no wire leads.
    • If the cut end does not need a power feed connector, insert the silicone end cap over the LED strip and add silicone to waterproof seal the end.
  • Surface Preparation and Installation:
    • Clean the installation area thoroughly.
    • Remove the paper backing from the strip and firmly press it down, avoiding air bubbles.
    • Install the LL-ZIP Strain Relief Clip away from the end of the strip to prevent surface irregularities.
  • Mounting Clips:
    • Install one CL2 mounting clip every 12 inches between the LEDs and secure them using the provided screws.

FAQs

  • Q: Can I install the product myself?
    • A: It is recommended to have the product installed by a qualified electrician to ensure safety and proper installation.
  • Q: Is the product suitable for wet locations?
    • A: Yes, the BA42WET model is suitable for wet locations.

Models BA42WET

Please read all instructions before installation and keep them for future reference!

  1. The product should be installed by a qualified electrician.
  2. Before installation ensure power is off at the fuse box to prevent electrical shock.
  3. Use only with Class 2 power unit. Utiliser seulement avec Classe 2 unite d’alimentation electrique.
  4. Suitable for wet Locations. Convient Aux Emplacements Humides.
  5. For under-cabinet or shelf mount.
  6. Conforms to UL STD 2108. Certified to CSA STD C22.2 No.250.0.

Installation directly

Installation directly to the mounting surface with factory lead wire

luminii-BA42WET-Linear-LED-Strip-FIG-1 \(1\)

  1. If the length of the BA42WET strip needs to be shortened on the job site, simply cut the LED strip in the between solder pads. Always cut from the end with no wire leads.luminii-BA42WET-Linear-LED-Strip-FIG-1 \(2\)
    • If the cut end does not need a power feed connector, insert the silicone end cap (EC-10MM-WET) over the BA42WET LED strip and add silicone (SIL-502-RTV) to waterproof seal the end.luminii-BA42WET-Linear-LED-Strip-FIG-1 \(3\)
  2. Clean the area thoroughly where the BA42WET strip will be installed.
    • Remove the paper backing from the BA42WET strip and firmly press down making sure there are no air bubbles that can cause surface irregularities.
    • Install LL-ZIP Strain Relief Clip 3” away from the end of the strip.luminii-BA42WET-Linear-LED-Strip-FIG-1 \(4\)
  3. Install one CL2 mounting clip every 12”, in between the LEDs.
    • Secure using the provided screws.luminii-BA42WET-Linear-LED-Strip-FIG-1 \(5\)
  4. Place the strain relief in the desired place. Make sure it is 3” away from the end of the strip.
    • Slide the zip tie through the strain relief opening.
    • Lay wire lead on top of strain relief.
    • Tighten the zip tie around the lead wire. Cut off excess zip tie.luminii-BA42WET-Linear-LED-Strip-FIG-1 \(6\)

Mounting Surface Connectors

Installation Directly to Mounting Surface using BA Connectors

luminii-BA42WET-Linear-LED-Strip-FIG-1 \(7\)

  1. If the length of the BA42WET strip needs to be shortened on the job site, simply cut the LED strip in the between solder pads. Always cut from the end with no wire leads.luminii-BA42WET-Linear-LED-Strip-FIG-1 \(8\)
  2. If the cut end does not need a power feed connector, insert the silicone end cap (EC-10MM-WET) over the BA42WET LED strip and add silicone (SIL-502-RTV) to waterproof seal the end.luminii-BA42WET-Linear-LED-Strip-FIG-1 \(9\)

Connector

  1. Check the polarity, refer to the plus sign on the power cap. Then remove the paper backing on the end of the LED Strip. Insert the LED strip into the tube, and push the strip until it touches the end wall of the tube.
    • Add silicone sealent into the tube.
    • Snap on the power feed cap, and push it down until hearing a “click“.luminii-BA42WET-Linear-LED-Strip-FIG-1 \(10\)
  2. Clean the area thoroughly where the BA42WET strip will be installed.
    • Remove the paper backing from the BA42WET strip and firmly press down making sure there are no air bubbles that can cause surface irregularities
    • Install LL-ZIP Strain Relief Clip 3” away from the end of the strip.luminii-BA42WET-Linear-LED-Strip-FIG-1 \(11\)
  3. Place the strain relief in the desired place. Make sure it is 3” away from the end of the strip.
    • Slide the zip tie through the strain relief opening.
    • Lay wire lead on top of strain relief.
    • Tighten the zip tie around the lead wire. Cut off excess zip tie.luminii-BA42WET-Linear-LED-Strip-FIG-1 \(12\)

RECOMMENDED LAYOUT FOR MULTIPLE ADJACENT RUNS OF LINELED FED WITH SEPARATE POWER SUPPLIES

  1. Position power supplies either in the middle of two runs or at the opposite ends. luminii-BA42WET-Linear-LED-Strip-FIG-1 \(13\)
  2. Always ensure power to the power supply is off! Follow the diagrams to connect power feed wires to the power supply. Refer to the power supply instructions for the wiring line voltage side.luminii-BA42WET-Linear-LED-Strip-FIG-1 \(14\)