geniani KW-JSQ10 250ml Erie Humidifier Instruction Manual
- June 5, 2024
- geniani
Table of Contents
PLEASE READ AND SAVE THESE INSTRUCTIONS
INSTRUCTION MANUAL
ERIE HUMIDIFIER 250 ML KW-JSQ10
Inquiries 1404-225-3955 Help Monday to Friday 9 AM to 5 PM EST Issues info@geniani.com
QUICK START GUIDE
CONDITIONS OF USE
For the proper use of the humidifier, the following conditions should be
met:
The suitable working environment for the humidifier: 40°F – 104°F (5°C –
40°C). Relative humidity: less than 80% RH. Clean water below 104°F (40°C)
used for machine operation. If the humidifier is not used for a long time, the
water channel and the water tank should be cleaned before use.
Please do not add perfume or essential oil to the water
INTRODUCTION
| The humidifier should always be placed on a firm, flat, waterproof surface
and out of reach of children and pets. Do not place a mist outlet directly in
front of children, walls or furniture.
---|---
Before using the humidifier, extend the USB cord and inspect for any signs of
damage.
Use a 5V power adapter. Make sure the USB power cord is away from heated
surfaces and out of the way to prevent the humidifier from being tipped over.
If the power cord is damaged, send it for professional repair; do not repair
it on your own. Do not use the power cord when coiled or with a twist tie in
someplace.
| The humidifier should not be left unattended in a closed room since air can
become saturated and leave condensation in front of the unit, on walls and
furniture.
---|---
If the product is not used for over three days, pull out the USB power line.
The humidifier should always be unplugged and emptied when not in operation or
while being cleaned.
The humidifier requires regular cleaning.
SAFETY INSTRUCTIONS
DANGER! Non-observance of the rules of the following note results in personal injury or material damage (electric shock, skin burns, fire).
- Do not move or tilt the humidifier while it is in operation. Plug and unplug the unit with dry hands.
- Never pull with the cord.
- Do not exploit the humidifier without water.
- Do not fill it with hot or boiled water.
- Do not touch the atomizer plate with sharp objects.
- Do not cover or insert objects into any opening on the unit.
- Do not block intake or output vents.
- Do not attempt to repair or fix any function of this humidifier. Doing so will void your warranty.
- Do not expose it to direct sunlight, high-temperature areas or near sensitive electronic equipment.
- Do not run the cord under rugs, carpets, runners, or similar coverings.
- Do not run the route cord under furniture or appliances.
- Do not put any medications, oils or fragrances into a water tank. Use essential.
- Do not use the humidifier outdoors; it is intended for indoor residential use only.
- Do not dispose of electrical appliances as unsorted municipal waste; use separate collection facilities. If damaged electrical appliances are disposed into landfills or dumps, hazardous substances can leak into the groundwater and cause health issues and pose the risk to overall well-being.
PARTS
OPERATING INSTRUCTIONS
- Make the humidifier circulate to the right after filling it with water.
- For the first time use, wait for 1-2 minutes to let the cotton filter get wet. Take out the cotton filter, put it in water for 30 seconds, and then put it back into the humidifier.
- Connect the USB cable with the correct adapter, power bank or laptop.
- Press the On/Off switch, the indicator light flashes once again, the humidifier enters intermittent spraying mode.
- Press the On/Off switch, the indicator light flashes once again, the humidifier enters intermittent spraying mode – sprays for 10 seconds in 10 seconds in turn.
- Press the On/Off switch the third time and the machine turns off.
- Press the On/Off switch for 3 seconds to turn the indicator light on or off.
CLEANING AND MAINTENANCE
To keep your humidifier running efficiently, clean it regularly. All
maintenance procedures should be done in the kitchen or bathroom on a water-
resistant surface near a faucet.
Please follow the procedures below:
- Use a soft cloth to clean the humidifier; don’t use petrol or other organic solvents. Do not put the whole humidifier into the water.
- After using it for 30 times or 30 days, please clean it accordingly: turn it off and pull out the power cord. Remove the engine part and remove the cotton bar cover, placing it in a dry, ventilated place. Use a soft brush to clean the water absorption hole.
- Clean the humidifier’s surface with a soft cloth and pack it in the box, and then put it in a dry place.
- To replace the cotton bar, turn the main engine anticlockwise. Turn the cotton bar cover anticlockwise, and it will open out. Then take out the cotton bar to replace it. After putting in a new one, please assemble it.
TROUBLESHOOTING
When you experience problems with the machine, please check the points below:
- Check if the power adapter has been connected to the machine.
- Make sure the adapter is correct.
- Make sure there is enough water in the container.
- Check if the atomizer plate is blocked. If it is, use a wet cotton bud to clean it.
- Check if the cotton bar has been polluted or is deteriorating rapidly. If so, please replace it and clean the water absorption hole at the bottom.
SPECIFICATIONS
Model: | Erie (KW-JSQ10) |
---|---|
Color: | White, Black, Gray |
Power: | 2 W |
Voltage: | 5 V |
Amperage | 0.4 A |
Plug: | Micro USB |
Capacity: | 8.45 fl oz (250 ml) |
Coverage: | up to 65 ft2 (6 m2) |
Operation: | up to 8 hours (intermittent mode) |
Continuous Mist Volume: | 1 fl oz/h (±0.3 fl oz) 130 ml/h (±10 ml) |
Intermittent Mist Volume: | 0.5 fl oz/h (±0.13 fl oz) 115 ml/h (±5 ml) |
Net Weight: | 8.6 oz (244 g) |
Gross Weight: | 10.9 oz (310 g) |
WARRANTY
The manufacturer does not bear any responsibilities when personal injury or
property loss is caused due to the following reasons:
Damage to the product due to improper use or misuse of the product. The
alteration, change, and maintenance of the product with other equipment
without following the instructions provided by the manufacturer.
After verification, if the defect of the product is directly caused by any
corrosive gas. After verification, if the defects are due to improper
operation during the transportation of the product. After verification, if the
problem or dispute is caused by the quality specification or the performance
of the parts and components that were produced by another manufacturer.
In case of operation, repair or maintenance of the unit without following the
manual’s instructions or related regulations. If the damage is caused by
natural calamities, improper environmental use of force majeure.
CUSTOMER SUPPORT
Inquiries Help Issues
1(404) 225-3955
Monday to Friday 9 AM to 5 PM
ESTinfo@geniani.com
We are proud of our perfect customer service, and we promise to treat you
like family. Feel free to contact us!
https://geniani.com/
To get more information, please visit our
websitewww.geniani.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>