VISHAY TCLT1000 Optocoupler Phototransistor Output SOP 4L Long Mini Flat Package User Guide
- June 14, 2024
- VISHAY
Table of Contents
- VISHAY TCLT1000 Optocoupler Phototransistor Output SOP 4L Long Mini Flat
- Product Information
- Product Usage Instructions
- FAQ
- DESCRIPTION
- FEATURES
- ORDERING INFORMATION
- ELECTRICAL CHARACTERISTICS
- PACKAGE DIMENSIONS
- Disclaimer
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
VISHAY TCLT1000 Optocoupler Phototransistor Output SOP 4L Long Mini Flat
Package
Product Information
Specifications
- Product Name: TCLT100. Series
- Manufacturer: Vishay Semiconductors
- Package Type: SOP-4L (Long Mini-Flat Package)
- Description: Phototransistor optically coupled to a gallium arsenide infrared-emitting diode
- Input Parameters:
- Reverse Voltage: 6V
- Forward Current: 60mA
- Forward Surge Current: 1.5A
- Power Dissipation: 100mW
- Junction Temperature: 125°C
- Output Parameters:
- Collector-Emitter Voltage: 70V
- Emitter Collector Voltage: 7V
- Collector Current: 50mA
- Collector Peak Current: 100mA
- Power Dissipation: 150mW
- Junction Temperature: 125°C
- Coupler Parameters:
- Total Power Dissipation: 250mW
- Operating Ambient Temperature Range: -55°C to +100°C
- Storage Temperature Range: -55°C to +125°C
- Soldering Temperature: 260°C
Features
- Optocoupler with phototransistor output
- 4-lead SOP-4L package
Agency Approvals
UL, cUL, VDE, BSI, FIMKO
Ordering Information
- Part Number: TCLT100#
- Package: SOP-4L
Product Usage Instructions
Installation
- Ensure the power is disconnected before installation.
- Identify the input and output terminals of the optocoupler.
- Connect the input terminals to the appropriate power source.
- Connect the output terminals to the desired load or circuit.
- Securely mount the optocoupler in its intended location.
Operation
- Apply power to the input terminals within the specified parameters.
- The optocoupler will detect and transmit the input signal to the output terminals.
- The output terminals can be connected to other components or circuits for further processing or control.
- Monitor the optocoupler and ensure it is functioning as expected.
Maintenance
There is no specific maintenance required for the optocoupler. However,
regular inspection and cleaning of the terminals and surrounding area are
recommended to ensure proper operation.
Safety Precautions
- Do not exceed the specified input and output parameters to prevent damage to the optocoupler.
- Ensure proper insulation and grounding to prevent electric shock.
- Avoid exposure to extreme temperatures or moisture.
- Follow all applicable safety guidelines and regulations when installing or operating the optocoupler.
FAQ
-
Q: What are the agency approvals for this product?
A: The product has UL, cUL, VDE, BSI, and FIMKO approvals. -
Q: What is the operating temperature range for the optocoupler?
A: The optocoupler can operate within a temperature range of -55°C to +100°C. -
Q: Can I use the optocoupler with higher input currents?
A: No, the maximum forward current for the optocoupler is 60mA. Exceeding this limit may cause damage to the device. -
Q: What is the package type for this optocoupler?
A: The optocoupler comes in a 4-lead SOP-4L (Long Mini-Flat Package).
DESCRIPTION
The TCLT100. series consists of a phototransistor optically coupled to a gallium arsenide infrared-emitting diode in a 4-lead SOP4L package.
APPLICATIONS
- Switchmode power supplies
- Computer peripheral interface
- Microprocessor system interface
FEATURES
- SMD low profile 4 lead package
- VIORM = 1050 V
- CTR flexibility available see order information
- Special construction
- Extra low coupling capacitance
- DC input with transistor output
- Creepage distance > 8 mm
- Material categorization: for definitions of compliance please see www.vishay.com/doc?99912
AGENCY APPROVALS
- UL1577, file no. E76222
- CSA (cUL) 22.2 bulletin 5A recognized file no. E-76222
- BSI: BS EN 41003, BS EN 60065 (BS 415), BS EN 60950 (BS 7002), certificate number 7081 and 7402
- DIN EN 60747-5-5 (VDE 0884)
- FIMKO: EN 60950
- CQC
Note
- See the safety standard approval list “Agency Table” for more detailed information.
ORDERING INFORMATION
Note
- Available only on tape and reel.
ABSOLUTE MAXIMUM RATINGS
ABSOLUTE MAXIMUM RATINGS (Tamb = 25 °C, unless otherwise specified)
PARAMETER| CONDITION| SYMBOL| VALUE| UNIT
INPUT
Reverse voltage| | VR| 6| V
Forward current| | IF| 60| mA
Forward surge current| tp £ 10 μs| IFSM| 1.5| A
Power dissipation| | Pdiss| 100| mW
Junction temperature| | Tj| 125| °C
OUTPUT
Collector emitter voltage| | VCEO| 70| V
Emitter collector voltage| | VECO| 7| V
Collector current| | IC| 50| mA
Collector peak current| tp/T = 0.5, tp £ 10 ms| ICM| 100| mA
Power dissipation| | Pdiss| 150| mW
Junction temperature| | Tj| 125| °C
COUPLER
Total power dissipation| | Ptot| 250| mW
Operating ambient temperature range| | Tamb| -55 to +100| °C
Storage temperature range| | Tstg| -55 to +125| °C
Soldering temperature| | Tsld| 260| °C
Note
- Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operational sections of this document. Exposure to absolute maximum ratings for extended periods of the time can adversely affect reliability.
ELECTRICAL CHARACTERISTICS
ELECTRICAL CHARACTERISTICS (Tamb = 25 °C, unless otherwise specified)
PARAMETER| TEST CONDITION| SYMBOL| MIN.| TYP.|
MAX.| UNIT
INPUT
Forward voltage| IF = 50 mA| VF| –| 1.25| 1.6| V
Junction capacitance| VR = 0 V, f = 1 MHz| Cj| –| 50| –| pF
OUTPUT
Collector emitter voltage| IC = 1 mA| VCEO| 70| –| –| V
Emitter collector voltage| IE = 100 μA| VECO| 7| –| –| V
Collector emitter cut-off current| VCE = 20 V, IF = 0 A| ICEO| –| 10| 100| nA
COUPLER
Collector emitter saturation voltage| IF = 10 mA, IC = 1 mA| VCEsat| –| –|
0.3| V
Cut-off frequency| VCE = 5 V, IF = 10 mA, RL = 100 W| fc| –| 110| –| kHz
Coupling capacitance| f = 1 MHz| Ck| –| 0.3| –| pF
Note Minimum and maximum values are testing requirements. Typical values are characteristics of the device and are the result of engineering evaluation. Typical values are for information only and are not part of the testing requirements.
CURRENT TRANSFER RATIO (Tamb = 25 °C, unless otherwise specified)
PARAMETER| TEST CONDITION| PART| SYMBOL| MIN.|
TYP.| MAX.| UNIT
IC/IF| VCE = 5 V, IF = 5 mA| TCLT1000| CTR| 50| –| 600| %
VCE = 5 V, IF = 10 mA| TCLT1002| CTR| 63| –| 125| %
TCLT1003| CTR| 100| –| 200| %
TCLT1004| CTR| 160| –| 320| %
VCE = 5 V, IF = 1 mA| TCLT1002| CTR| 22| 45| –| %
TCLT1003| CTR| 34| 70| –| %
TCLT1004| CTR| 56| 100| –| %
VCE = 5 V, IF = 5 mA| TCLT1005| CTR| 50| –| 150| %
TCLT1006| CTR| 100| –| 300| %
TCLT1007| CTR| 80| –| 160| %
TCLT1008| CTR| 130| –| 260| %
TCLT1009| CTR| 200| –| 400| %
SAFETY AND INSULATION RATINGS
PARAMETER| CONDITION| SYMBOL| VALUE| UNIT
Partial discharge test voltage – routine test| 100 %, ttest = 1 s| Vpd| 2| kV
Partial discharge test voltage – lot test (sample test)| tTr = 60 s, ttest =
10 s, (see figure 2)| VIOTM| 8| kVpeak
Vpd| 1.68| kVpeak
Isolation test voltage (RMS)| | VISO| 5000| VRMS
Insulation resistance| VIO = 500 V| RIO| 1012| W
VIO = 500 V, Tamb = 100 °C| RIO| 1011| W
VIO = 500 V, Tamb = 150 °C (construction test only)| RIO| 109| W
Forward current| | Isi| 130| mA
Power dissipation| | Pso| 265| mW
Rated impulse voltage| | VIOTM| 8| kV
Safety temperature| | Tsi| 150| °C
Comparative tracking index| | CTI| 175|
Clearance distance| | | 8.0| mm
Creepage distance| | | 8.0| mm
Insulation distance (internal)| | | 0.40| mm
Note According to DIN EN 60747-5-2 (VDE 0884) (see figure 2). This optocoupler is suitable for safe electrical isolation only within the safety ratings. Compliance with the safety ratings shall be ensured by means of suitable protective circuits.
SWITCHING CHARACTERISTICS (Tamb = 25 °C, unless otherwise specified)
PARAMETER| TEST CONDITION| SYMBOL| MIN.| TYP.|
MAX.| UNIT
Delay time| VS = 5 V, IC = 2 mA, RL = 100 W, (see figure 3)| td| –| 3| –| μs
Rise time| VS = 5 V, IC = 2 mA, RL = 100 W, (see figure 3)| tr| –| 3| –| μs
Fall time| VS = 5 V, IC = 2 mA, RL = 100 W, (see figure 3)| tf| –| 4.7| –| μs
Storage time| VS = 5 V, IC = 2 mA, RL = 100 W, (see figure 3)| ts| –| 0.3| –|
μs
Turn-on time| VS = 5 V, IC = 2 mA, RL = 100 W, (see figure 3)| ton| –| 6| –|
μs
Turn-off time| VS = 5 V, IC = 2 mA, RL = 100 W, (see figure 3)| toff| –| 5| –|
μs
Turn-on time| VS = 5 V, IF = 10 mA, RL = 1 kW, (see figure 4)| ton| –| 9| –|
μs
Turn-off time| VS = 5 V, IF = 10 mA, RL = 1 kW, (see figure 4)| toff| –| 10|
–| μs
TYPICAL CHARACTERISTICS (Tamb = 25 °C, unless otherwise specified)
PACKAGE DIMENSIONS
PACKAGE MARKING (example)
TAPE AND REEL DIMENSIONS (in millimeters)
HANDLING AND STORAGE CONDITIONS
- ESD level: HBM class 2
- Floor life: unlimited
- Conditions: Tamb < 30 °C, RH < 85 %
- Moisture sensitivity level 1, according to J-STD-020
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non- infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein.
Hyperlinks included in this datasheet may direct users to third-party websites. These links are provided as a convenience and for informational purposes only. Inclusion of these hyperlinks does not constitute an endorsement or an approval by Vishay of any of the products, services or opinions of the corporation, organization or individual associated with the third-party website. Vishay disclaims any and all liability and bears no responsibility for the accuracy, legality or content of the third-party website or for that of subsequent links.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
For technical questions, contact:
optocoupleranswers@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED
HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT
www.vishay.com/doc?91000
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>