Aluratek ADIT01F Non-Contact Forehead Thermometer User Manual

June 7, 2024
Aluratek

Aluratek ADIT01F Non-Contact Forehead Thermometer User Manual

Aluratek ADIT01F Non-Contact Forehead Thermometer User
Manual

Operating Instructions

Aluratek ADIT01F Non-Contact Forehead Thermometer - Take out the thermometer
and open the battery

1. Take out the thermometer and open the battery lid to install 2 *AAA batteries

2. Keep distance of 2-3 inches from thermometer probe to the middle of forehead, please do not contact forehead directly

Aluratek ADIT01F Non-Contact Forehead Thermometer - Select measurement mode
and click the measurement button to start taking
temperature

3. Select measurement mode and click the measurement button to start taking temperature

Aluratek ADIT01F Non-Contact Forehead Thermometer - Reading displays on the
screen after successful measurement

4. Reading displays on the screen after successful measurement

Instruction Manual

Introduction & classification

This is a Non-Contact Forehead Thermometer applicable to forehead measurement. The thermometer measures body temperature by collecting heat radiation emitting from forehead. New probe structure is adopted in this thermometer. It’s simply operational, hygeian, reliable and highly accurate. Users can get precise reading within one second by one touch. This thermometer is cost- effective and is widely used in schools, customs, hospitals and for family use.

Intended Use & Indication for use: The Non-Contact Forehead Thermometer is an infrared thermometer intended for the intermittent measurement of human body temperature in people of all ages.

This thermometer is classified as a Class IIa(for CE)/class II(for FDA) Medical Device, sorted as internally- powered equipment and type BF application device. It’s prohibited to use this thermometer in flammable anesthetic gas or gas mixture of air and oxygen or nitrous oxide. This is a continuous operation equipment.

Working principle

Any object can generate certain proportion of infrared radiant energy as per its own temperature. The radiant energy and its wavelength distribution are subjected to its surface temperature. Based on this principle, this thermometer is designed to detect infrared radiation at 5~14um by highly precise infrared sensor. By adopting this high quality sensor plus special calculation and calibration, this thermometer is able to take accurate body temperature.

Safety precautions

Warning:

  • Using this thermometer is not intended as a substitute for consultation with your physician. It is dangerous for users to perform a self-evaluation and self-treatment based on the measuring result. please follow doctor’s instruction.
  • Keep the thermometer out of reach of children ,please consult the doctor at once in case of accidental swallow of battery or other component.
  • Don’t throw the battery into fire

Notice:

  • The device is precision instrument, don’t drop, tramp or impose any vibration or impact on the thermometer.
  • Do not touch the lens of the probe with your fingers and disassemble the device by yourself.
  • Please make sure your forehead is clean before measuring forehead temperature.
  • Please stay still indoors about 30 minutes after exercise, eating or bathing before measuring.
  • Please place the thermometer indoors for about 30 minutes if ambient temperature varies a lot before using.
  • Please collect the record of Individual temperature under the good condition of body in usual days as a reference for checking fever or not.
  • Do not measure the sites of scarred tissue or tissue compromised by skin disorders because they will affect the accuracy of measurement.
  • Do not measure if patient is treated with certain drug therapies because body temperature may rise in the drug within the effort time limit.
  • Do not immerse the device into water or any other liquid, do not expose to the sun.
  • Do not use a mobile or cordless hone near the thermom measuring. Do not use the thermometer near a mobile or cordless hone.
  • Please don’t measure body temperature in strong electromagnetic interference environment (such as microwave, high frequency equipment operation environment) to ensure the accuracy of measurement data.
  • This thermometer only a personal device, please do not share with others.
  • Please store the thermometer according to the technical specifications.
  • Keep the sensor and probe cavity clean before use and after use.
  • The materials (ABS) of contact with patient has passed the ISO 10993-5 and ISO 10993-10 standard test, no toxicity, allergy and irritation reaction. They are compliant with the MDD requirements based on the current science and technology, and other potential allergic reactions are unknown.
  • The patient can measure, read data and replace battery under normal circumstances and maintain the device and its accessories according to the user manual.
  • The PATIENT is an intended OPERATOR.

Recommendations:

  • Don’t use this thermometer for other purposes.
  • It is forbidden to leave the product exposed to any chemical solvent, direct sunshine or high temperature in case of damaging the product or the battery.
  • Do not measure while talking on the phone.
  • Please report to MANUFACTURER if any unexpected operation or events occur.

Features

  • Measurement mode for human body and object available,one button to switch measurement mode;
  • Beeper for high temperature;
  • ℃/℉ reading available;
  • Automatic shut off;
  • Storage of last 10 readings;
  • 3 Colors Backlight LCD for easy reading.

Technical parameters

Technical parameters

Aluratek ADIT01F Non-Contact Forehead Thermometer - Technical parameters
2

Illustration

Aluratek ADIT01F Non-Contact Forehead Thermometer -
Illustration

Display & icons

Aluratek ADIT01F Non-Contact Forehead Thermometer - Display &
icons

Function definition of buttons

Aluratek ADIT01F Non-Contact Forehead Thermometer - Function definition of
buttons

Setting

User can change reading scale between Celsius and Fahrenheit, and change measurement mode between human body mode and object mode .

Measurement mode setting:

When thermometer is on, it displays current measurement mode ( fig.9.1). Press the “Mode” button to change measurement mode( fig.9.2).

Reading scale setting:

When thermometer is on, it displays current Reading scale. Press the “C/F” button to select reading scale.

Notice:

  1. Temperature under human body mode is obtained from dynamic compensation of environmental temp and forehead surface temp.
  2. Object temperature mode is to test surface temperature of an object. The temperature get from forehead under this mode is merely temperature of forehead surface but not body temperature.

Measurement

Body temperature
  • Press measurement button to turn on thermometer and it displays boot screen (fig.10.1). After POST and two beeps, it will display value of last reading and be ready for measurement (fig.10.2).
  • Make sure the thermometer is under body mode.
  • Keep distance at 5cm to 8cm from thermometer probe to the middle of forehead (fig.10.3). Press measurement button and then it gives a beep to indicate measurement is finished and value will be displayed (fig.10.4). If measurement value exceeds alarm value(Defaulted value is 38℃),it gives beep. beep. beep as a indication.
  • After measurement, if the thermometer is idle for 30 seconds, it will display OFF (fig.10.5) and gives a beep and shut off automatically.

Aluratek ADIT01F Non-Contact Forehead Thermometer - Figure
10.1,10.2,10.3,10.4,10.5

Object temperature
  • Press measurement button to turn on thermometer (fig.10.6).
  • Make sure the thermometer is under object mode.
  • Keep vertical distance at 5cm to 8cm from object to measurement probe.
  • Press measurement button and then it gives a“beep”to indicate measurement is finished and value will be displayed (fig.10.7).
  • After measurement, if the thermometer is idle for 30 seconds, it will display “OFF” (fig.10.8) and gives a “beep” and shut off automatically.

Aluratek ADIT01F Non-Contact Forehead Thermometer - Figure
10.6,10.7,10.8

Notice:

  1. The value under this mode is object surface temperature instead of core temperature.
  2. The default value of edinfrared emissivity is 0.95. The reading will deviate from the real temperature because of different emissivity. For example, the reading on stainless steel is obviously lower than real temperature. BE CAUTIOUS FOR SCALDING.
Exceeding measurement range

Body mode:

When measurement value is lower than 34.0ºC(93.2℉), it displays Lo (fig.10.9) and gives “beep. beep. beep. beep”, with the color of backlight turning red. When measurement value is higher than 43.0 ºC(109.4℉), it displays Hi (fig.10.10) and gives “beep. beep. beep. beep”, with the color of backlight turning red.

Object mode:

When measurement value is lower than 0ºC(32℉), it displays Lo (fig.10.11) and gives “beep. beep. beep. beep”, with the color of backlight turning red.
When measurement value is higher than 93ºC(199.4℉), it displays Hi (fig.10.12) and gives “beep. beep. beep. beep”, with the color of backlight turning red.

Notice:

When surrounding temperature is lower than 15.0ºC(59℉) or higher than 40.0ºC(104℉), it displays Err(fig.10.13) and gives “beep.beep.beep.beep”, with the color of backlight turning red. Under this condition, it’s not allowed to use this thermometer or accuracy is not assured.

Aluratek ADIT01F Non-Contact Forehead Thermometer - Figure
10.9,10.10,10.11,10.12,10.13

Battery replacement

  • Open the battery lid and take out exhausted battery.
  • Put into 2 AAA batteries and close up battery lid. After new battery is installed, the color of backlight turns in the order of green , orange and red , each of them flashing one time respectively, with a “beep” heard. If no beep is heard, please check if the positive and negative pole is correct (see fig.11.1).

Notice:

  1. Take out battery in case the thermometer is not used for a long time. Don’t put the battery to fire.
  2. Dispose battery according to local regulations.

Maintenance & tips

  • Make sure the sensor and probe cavity is clean otherwise it will affect accuracy.
    Cleaning method for probe:
    1.Use the cotton stick or soft cloth with water or alcohol to wipe the casing.
    2.Use the cotton stick or soft cloth with alcohol to wipe the sensor surface or probe cavity gently. Don’t use thermometer before alcohol is vaporized.

  • Read this manual book thoroughly before use. Make sure battery is well installed.
    It is not allowed to put the thermometer in any liquid or expose to strong sunlight or extremely low temperature.

  • Strong crash or hit to the product will cause its damage.

  • Do not dismantle this thermometer by yourself.

  • Keep the thermometer from children’s reach.

  • Do not use the thermometer under circumstance of strong electromagnetic interfere

  • The measurement results are probably fluctuating due to improper measurement ways.

  • Please practice adequate measurements in order to improve your skill.

  • The measurement results can not supersede a doctor’s diagnosis.

  • Special maintenance is unnecessary for this thermometer. Please contact distributor or manufacturer in case of malfunction

Trouble shooting

Aluratek ADIT01F Non-Contact Forehead Thermometer - Trouble
shooting

Standard list

Aluratek ADIT01F Non-Contact Forehead Thermometer - Standard
list

Aluratek ADIT01F Non-Contact Forehead Thermometer - Standard list
2

Disposal

Dispose of the device in accordance with the regulation applicable at the place of operation. Dispose of at public collection point in the EU countries – 2012/19/EU WEEE Directive. If you have any queries, please refer to the local authorities responsible for waste disposal.

NOTES:
Please act according to the native law to proceed to handle the battery and wastes.
Take out the battery if you are not going to use the unit for a long time.

Dispose of empty battery at your retail store or at appropriate collection sites according to national or local regulations to protect environment. Dispose of at public collection point in the EU countries – 2006/66/EC Directive.

Normalized symbols

Aluratek ADIT01F Non-Contact Forehead Thermometer - Normalized
symbols

EMC Declaration

  1. Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally.
  2. Use of accessories, transducers and cables other than those specified or provided by the manufacturer of this the Infrared Thermometer could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation.
  3. Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the Infrared Thermometer, including cables specified by the manufacturer Otherwise, degradation of the performance of this equipment could result.

Guidance and manufacturer´s declaration – electromagnetic emission – for all EQUIPMENT AND SYSTEMS

Aluratek ADIT01F Non-Contact Forehead Thermometer - EMC
Declaration

Guidance and manufacturer’s declaration – electromagnetic immunity – for all EQUIPMENT and SYSTEMS

The infrared thermometer is intended for use in the electromagnetic environment specified below.
The customer or the user of infrared thermometer should assure that it is used in such an environment.

Aluratek ADIT01F Non-Contact Forehead Thermometer - EMC Declaration
2

NOTE:  UT is the a. c. mains voltage prior to application of the test level.

Guidance and manufacturer´s declaration – electromagnetic emission – for all EQUIPMENT AND SYSTEMS

Aluratek ADIT01F Non-Contact Forehead Thermometer - EMC Declaration
3

NOTE 1 At 80 MHz and 800 MHz, the higher frequency ra nge applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic is affected by absorption and reflection from structures, objects and people.

Aluratek ADIT01F Non-Contact Forehead Thermometer - EMC Declaration
4

For transmitters rated at a maximum output power not listed above the recommended separation distance d in metres (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter
manufacturer.
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people

Technical Support and Warranty

If you need further assistance, please contact the Aluratek support department for troubleshooting prior to returning this device.

E-mail: support@aluratek.com
Web: www.aluratek.com/helpdesk
Local (Irvine, CA):714-586-8730
Toll free: 1-866-580-1978

Aluratek warrants this product against defect in material or workmanship for
1 YEAR from the date of purchase.
For more information, please visit: https://aluratek.com/warranty-return- policy
You can register your product online at: https://aluratek.com/product- registration

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Aluratek User Manuals