Technical amendments reserved Recessed ceiling downlight for indoor use
50 336.1 Recessed Ceiling Downlight
Instructions for use
Application
Recessed ceiling downlight · Indoor luminaire with symmetrical wide beam light
distribution.
For installation in suspended ceilings of 5-25 mm in interior applications.
Product description
Recessed LED ceiling luminaire with a remote power supply unit
Luminaire housing made of cast aluminium
Fixing is achieved by using
2 adjustable fastening springs
Reflector surface made of pure aluminium
Light-diffusing disc
Recessed opening ø 170 mm
Required installation depth 90 mm
Connecting cable 2 x 1,0@
External LED power supply unit
220-240 V ≂ 0/50-60 Hz
Safety class II
– Safety mark
– Conformity mark
Weight: 0.45 kg
This product contains light sources of energy efficiency classes D, E
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
Module connected wattage | 10 W |
---|---|
Luminaire connected wattage | 12 W |
Rated temperature | ta = 25 °C |
Ambient temperature | ta max = 45 °C |
When installed in heat-insulating material | ta max = 25 °C |
50 336.1 K3
Module designation | LED-0859/930 |
---|---|
Colour temperature | 3000 K |
Colour rendering index | CRI > 90 |
Module luminous flux | 1355 lm |
Luminaire luminous flux | 1044 lm |
Luminaire luminous efficiency | 87 lm / W |
50 336.1 K4
Module designation | LED-0859/940 |
---|---|
Colour temperature | 4000 K |
Colour rendering index | CRI > 90 |
Module luminous flux | 1475 lm |
Luminaire luminous flux | 1136 lm |
Luminaire luminous efficiency | 94,7 lm / W |
Installation
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
Cover the recessed opening with the stop ring of the luminaire housing.
The luminaire housing is then fixed in the recessed opening via two springs.
Installation in suspended ceilings:
A recessed opening of 170 mm with a minimum depth of 90 mm is required. The
lateral clearance from the installation housing to parts of the building must
be at least 50 mm.
The minimal thickness of the ceiling panel must be 5 mm and must not be
greater than 25 mm.
A ceiling panel with less than 5 mm thickness must be reinforced on the
reverse.
The electrical connection must be made on site in the appropriate safety class
on the LED power supply unit connecting cable. A distribution box must be
used. Ensure the correct assignment of the connecting cable. Establish the
mains connection on the brown (L) and blue (N) wires.
Guide the LED power supply unit through the opening in the ceiling and
position it on the suspended ceiling.
Place the LED unit on top of the luminaire housing over the reflector and lock
it in place by turning it to the right.
Compress the fastening springs of the luminaire housing on both sides and
slide the luminaire housing into the recessed opening.
The fastening springs lock into place behind the ceiling panel.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by
qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Close the luminaire.
Spares
LED power supply unit | DEV-0375/350 |
---|---|
LED module 3000 K | LED-0859/930 |
LED module 4000 K | LED-0859/940 |
Reflector | 76 001 620 |
BEGA Gantenbrink-Leuchten KG · Postfach 31 60
· 58689 Menden
· info@bega.com