Kimberly-Clark 53697 Automatic Roll Towel Recessed Dispenser Housing without Trim Panel User Guide
- June 3, 2024
- Kimberly-Clark
Table of Contents
Automatic Roll Towel
Recessed Dispenser Housing without
Trim Panel – User Guide
|
---|---
Use of this Dispenser
Not recommended for outdoor installation or in wet environments. Do not attempt to clean the dispenser with a water jet or by spraying the dispenser directly. Follow the installation and usage instructions. Only use genuine Kimberly Clark Professional product refills intended for the specific model. The dispenser can be cleaned using a damp cloth and detergent, do not use abrasive cleaning products.
Use Caution, Edges may be sharp when dispenser is open or during faceplate installation.
Need more information?
These instructions and additional resources are available at
www.kcprofessional.com.
General Safety Information
This dispenser can be used by children over the age of 8 years old and persons
with reduced physical, sensory or mental capabilities, or lack of experience
and knowledge, provided they have been given supervision or instruction
concerning use of the dispenser by a person responsible for their safety.
Access to the service area is restricted to persons who have knowledge and
practical experience of the dispenser, in particular as far as safety and
hygiene are concerned.
This dispenser is not a toy and shall not be used by children as such.
Children shall not perform cleaning or user maintenance of this dispenser.
High-risk individuals are not expected to use this dispenser safely unless
continuous supervision is given.
- Not Included
** For additional faceplates, contact your sales representative.
Module Installation for Recessed Dispensers
For instructions on how to install the module into a wall-mounted Roll Hand Towel Dispenser, please refer to the Automatic Roll Towel Dispenser instructions found on www.kcprofessional.com.
Note: Install the housing assembly into the wall before installing the module. For instructions on how to install the housing assembly, go to www.kcprofessional.com.
-
Remove the cover by closing it about halfway. Align bottom edge of cover with vertical alignment line. The key feature on the inside of the cover should line up with it’s
corresponding slot on the dispenser body, allowing the cover to be flexed off. -
Remove the cover.
-
Once the housing assembly is installed, align the back of the module with the angled posts on the back wall and lower into position. Ensure that the module is level once positioned.
-
Insert screws, one on each side, to secure the module in its position inside the dispenser shell.
-
Replace the cover by lining up the slot feature on the inside of the cover with its corresponding slot on the housing assembly in order to snap the cover back on. Allow the cover to fall open once replaced.
-
Insert the cable jack into the module (cable shown in red).
-
See Module Installation Manual for next steps to install.
Dispenser Access
- To unlock the dispenser, insert key into lock and rotate the key a quarter turn towards the wall. Gently pull the cover forward.
- Support the cover while opening.
Cover Removal
Remove dispenser cover before installing the cage. Refer to Dispenser Access section for instructions to unlock the dispenser.
- Remove the cover by closing it about halfway. Align bottom edge of cover with vertical alignment line. The key feature on the inside of the cover should line up with it’s corresponding slot on the dispenser body, allowing the cover to be flexed off.
- Remove the cover.
Cage Installation
Enclosed**
When installing the dispenser ensure to follow all appropriate safety
precautions and wear proper safety equipment including gloves.
Note: This unit is for an install with studs on 16 inch centers or less.
** For push buttons and other available parts, contact your sales
representative.
Cage Installation (continued)
Tools Required
Installation Options
There are two methods of installation that can be used for this dispenser: with and without the Stainless Steel Recessed Wall Unit with Trash Receptacle (35370). Instructions on how to install each option are detailed in the following sections.
|
---|---
Cage Installation
-
Determine the location to mount the dispenser using a stud finder and mark the rough wall opening.
-
Note that it is important to install the dispenser 12 inches above the counter or other obstruction. Please consider this when deciding where to install the dispenser.
-
While measuring an installation location, note that the lock position can be reversed. Ensure that you have adequate space to access it.
-
Cut an investigation hole to ensure that there is not plumbing, electric, etc. in the install area and use a flash light or right angle mirror to check the area.
-
The first cut for the install should be 12 inches from a counter or 53 inches from the floor. Verify your region’s legal height requirements.
Cage Installation (continued)
-
Test the fit of the dispenser in the hole.
-
Determine if additional framing is needed for the install. For jobs on 16 inch centers, additional framing will be needed. Use 2 x 4”‘s and 1 x 4”‘s and balance the framing
on each side as needed.
-
Measure the fit to the dispenser again to ensure that the fit will be right. Shims may be needed at this point.
-
Insert the unit into the wall.
-
Before adding screws, check to see that the unit is level.
-
Install dispenser using 4 screws in the side of the housing attaching to the studs in the wall. Add 2 screws on the top side and two on the bottom side of the housing. Do
not overtighten.
There are two methods of installation that can be used for this dispenser housing: with and without the trash module. Instructions on how to install the housing without the trash module can be found in the previous section. Instructions on how to install the housing into the Stainless Steel Recessed Wall Unit with Trash Receptacle (35370) are presented in the following section.
Cage Installation
Cage Installation (continued)
-
Remove the 6 white plastic thumb screws on top of the trash can unit to prepare to install the towel dispenser. Set thumb screws aside.
-
Use a flathead screwdriver to remove the roll holding arms (2) by pushing on the tab shown in frame 2.
-
Locate 6 screws on the inside of the dispenser assembly for removal. The cover should be kept off in these steps. Refer to the Cover Removal section.
-
Remove screws and set aside.
-
Remove housing from the cage. Set housing aside.
-
Fit in the paper towel back housing of the dispenser into the trash can unit. Check to make certain that the unit is level.
-
Add the thumb screws back onto the pins to hold the towel dispenser to the trash can receptacle. Check level again.
-
Replace the dispenser housing onto the installed cage.
-
Replace the 6 screws to secure the housing to the installed cage.
-
Replace the roll holding arms by sliding them back on the designated pegs until the tab clicks in, confirming the arms are securely installed.
Do Not Flush
Dispose in Trash|
---|---
Do Not Flush|
Label Placement Recommendation
Flushing of non-flushable products, such as paper towels, can cause internal
plumbing issues as well as issues in municipal sewage systems.
To help avoid such issues, Kimberly Clark Professional* provides “Do Not
Flush” labels for stainless steel dispensers.
These labels have a non-permanent adhesive and may be removed at a later date
if desired.
Legal
®/™ Trademarks of Kimberly-Clark Worldwide, Inc. or its affiliates. © KCWW
®/™ Marques de commerce de Kimberly-Clark Worldwide, Inc. ou de ses filiales.
© KCWW
Parts made in Mexico and China, Assembled in Mexico /
Pièces fabriquées au Mexique et en Chine, et assemblées au Mexique /
Partes hechas en México y China, armado en México
Peças produzidas no México e na China, montagem no México /
Distributed in the U.S. by Kimberly-Clark Global Sales, LLC, Roswell, GA
30076-2199