ROBUS R075LEDE-01 7.5W Golf Led with Pro-Diffuser Emergency Instruction Manual

June 6, 2024
ROBUS

**ROBUS R075LEDE-01 7.5W Golf Led with Pro-Diffuser Emergency Instruction Manual

**

PLEASE READ INSTRUCTION BEFORE COMMENCING INSTALLATION AND RETAIN FOR FUTURE REFERENCES.
! Electrical products can cause death or injury, or damage to property. If in any doubt about the installation or use of this product, consult a competent electrician.

Note:
Product technical information and specification may change over time without prior notification. For the latest technical information please visit our web site www.robus.com or robusdirect.com

-10°C < Ta < +35°C, 220V – 240V ~ 50/60Hz, Class I, IP65, Battery Warranty: 2 Years Luminaire is non-dimmable

Suitable for mounting on a normally flammable surface.

Installation

  1. Ensure mains supply is switched off before commencing work

  2. Ensure there is at least 100mm of free space around the luminary location

  3. Remove trim/ diffuse and LED plate from base of the fitting

  4. Drill cable entry and mounting holes in the base

  5. Mark fixing hole positions on wall, check location buried cables, pipes or other building services before drilling.

  6. Feed supply cables through cable entry hole and attach base to surface of wall

  7. Write installation date on battery and connect battery

  8. Connect wires from switched supply to terminals on metal plate, brown to PL,Blue to N and green/yellow to earth;For fitting always on , link terminal “SL” to terminal “PL”, fitting controlled by switch connect switched live wire to terminal SL and permanent live to PL.
    Note: if “SL” terminal not connected, fitting works as non-maintained.

  9. Refit LED plate and trim/ diffuse to base. Attention:In order to protect the battery life, please disconnect the battery if the power supply shut off over 3 days.

Switch on supply:
The green led should come on indicating correct battery charge status, all LEDs will come on.When supply to the switched live PL is lost, battery will operate fitting in emergency mode.

Testing

The emergency lighting must be inspected and tested regularly in accordance with local codes of practice:
note: for safety reasons tests should be carried out during daylight hours.
The minimum recommended test schedule is as follows: After installation, allow 24 hours to ensure full battery charge and then interrupt the supply; the maximum duration time is 3 hours check that LEDs are still lighting.

  1. Daily check that charge indicator LED is working
  2. Monthly, interrupt mains for a short period and check LED lights
  3. Annual 12 month check, full duration test. Interrupt mains supply, LEDs will light and should last for a minimum 3 hours operation: batteries must be replaced when they can no longer support 3 hour operation.
  4. Complete record sheet on installation and retain in maintenance file.
  5. Update file with ongoing test records for inspection by fire officer or other duly authorized person

Market Surveillance: These products contain light sources of energy efficiency as detailed below.
R075LED-LS: Class D
R100LED-LS: Class D
R150LED-LS: Class D
Disconnect driver input and output connections.
Remove mounting screws and remove driver.

Information for the Product user

  1. Please note the requirement to dispose of Waste Electrical & Electronic Equipment separately from household waste (WEEE marked with crossed out wheelie bin symbol).
  2. Please consider your role in contributing to re-use and recycling by returning this product at end of life to a collection center for waste electrical equipment or a Civic Amenity site, or to a retail outlet from which you are purchasing a replacement.
  3. This equipment may contain substances that are hazardous to health and the environment if disposed of carelessly. It is important that it is separated from normal household waste and recycled in the WEEE chain
  4. The “crossed out wheelie bin symbol” on a product indicates this equipment must not be disposed of in normal household waste, but should be disposed of according to local WEEE regulations.

Installation and Maintenance Record

Installer

Installation:  Type

Installation test duration & Date

Month Maand Test 1st Year 2st Year 3st Year 4st Year 5st Year
Signed Date Signed Date Signed Date Signed
1 Short
2 Short
3 Short
4 Short
5 Short
6 Short
7 Short
8 Short
9 Short
10 Short
11 Short
12 Short
3Hr.

UK: Bracknell Enterprise & Innovation Hub, Ocean House, 12th Floor, The Ring, Bracknell, Berkshire RG12 1AX, UK

Tel: +353 1 7099000
Fax: +353 1 7099060
Email: [email protected]
Website: www.robus.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ROBUS User Manuals

Related Manuals