ROBUS R8WDLCCT3-01 Slogan3 8W CCT Selectable 3000K 4000K 6500K Slim LED Downlight Instruction Manual
- June 3, 2024
- ROBUS
Table of Contents
ROBUS R8WDLCCT3-01 Slogan3 8W CCT Selectable 3000K 4000K 6500K Slim LED
Downlight
PLEASE READ INSTRUCTION BEFORE COMMENCING INSTALLATION AND RETAIN FOR
FUTURE REFERENCES.
Electrical products can cause death or injury, or damage to property. The
Installation must be carried out by a qualified electrician.
Note: Product technical information and specification may change over time without prior notification. For the latest technical information please visit our web site www.robus.com.au
220-240V~50/60Hz, Class II, IP44
Suitable for mounting on a normally flammable surface. See website for
compatible dimmer list: www.robus.com.au
Installation
-
Ensure mains supply is switched off before commencing work or changing colour temperature.
-
This luminaire requires a round hole Ø90-95mm cut into the ceiling for correct installation.
-
Before cutting, ensure that the hole does not impinge on joists, pipe work, cables or other building services.
-
Move switch on top of the driver to select colour temperature: 3000K, 4000K or 6500K
-
Connect supply: Insert plug in the socket.
Alternatively connect supply cables: Brown to Live, Blue to Neutral. -
Place the diver above the insulation.
-
Offer luminaire up to cut-out. Hold retention spring vertically against fitting body, push fitting through the cut-out until the springs come down on the upper side of the plasterboard.
Ensure that the fitting is secure and the bezel is tight against the ceiling.
WARNING: DO NOT CHANGE CCT WHEN THE FITTING IS ON!!
Safety instruction
Warning
Luminaire marked as IC-F/IC-4 according to ASNZS60598-2.2. IC-F/IC-4 Rating
only applies when luminaires are installed in a ceiling with “Mineral Glass
Fibre Type Insulation”.
Building insulation abutting or within 100mm horizontally of the luminaire must meet the following requirements; 90°C for luminaire rating IC-F/IC-4, IC or CA80 and 150°C for luminaire rating CA135.
- Be of a type that can maintain its dimensions and structural integrity when exposed to the maximum surface temperatures of the class of luminaire, being 90°C.
- Be of a type able to withstand a 30 second needle flame test carried out in accordance with AS/NZS 60695.11.5 with the flame applied to all surfaces of the test sample.
Loose fill insulation as defined in NZS 4246 is not permitted to abut or cover this luminaire or be used anywhere near this downlight.
The installation must be carried out by a suitably qualified person.
Caution;
Recessed Luminaires may pose an increased risk of fire or property damage if
not installed according to the instructions provided.
As specified in AS/NZS 60598.1, AS/NZS 60598.2.2, and AS/NZS 3000: 2007 Clause 4.5.2.3.3(a), the fitting complies with the requirements for the F Mark, meaning that the temperature of the fitting does not exceed 90°C when abutted to or covered with thermal insulation material.
Although the fitting may be safely covered with insulation material, we recommend that the luminaire be abutted to but not covered with insulation material in order to maximise the lifetime of the fitting. LED lifetime can be maximised by maintaining as low an operating temperature as possible.
Note:
- The luminaire must be disconnected before carrying out any insulation resistance testing.
- Ensure when working at height that proper care and procedures are employed along with suitable equipment used.
LED Group Australia Pty Limited Suite B, 2 Pittwin Road Capalaba
Queensland 4157
Australia
Tel: 07 3890 5444 Fax: 07 3890 4777
Email: purchases@robus.com
Website: www.robus.com.au
Tel: +64 3668 5285
Email: nz_purchases@robus.com
Website: www.robusled.co.nz