ACURITE 01604 Weather Center with Color Digital Display Instruction Manual
Congratulations on your new AcuRite product. To ensure the best possible product performance, please read this manual in its entirety and retain it for future reference.
Unpacking Instructions
Remove the protective film that is applied to the LCD screen prior to using this product. Locate the tab and peel off to remove.
Package Contents
- Display unit
- 3-in-1 sensor
- Sensor mounting bracket
- Mounting hardware
- Power adapter
- Instruction Manual
PRODUCT REGISTRATION
Features & Benefits
3-in-1 SENSOR
-
Temperature & Humidity Sensors (internal)
-
Release Lever for Battery Access
-
Mounting Point
-
Wind Speed Anemometer
-
Mounting Hardware
Includes anchors and screws.
Qty
4,1
Diameter4, #6 or #8
Length
1″
1/4″ or 3/8″ -
Mounting Bracket
-
A-B-C Switch (not shown) ID code that must match display’s A-B-C switch to ensure units synchronize.
DISPLAY UNIT
-
Current Outdoor Temperature
Arrow icon indicates the direction the temperature is trending. -
Seasonal Information
Wind chill will show when temperatures are below 40oF (4oC), Dew Point when temperature is 41- 79oF (5-26oC), and Heat Index when temperature is over 80oF (27oC). -
Average Wind Speed
Based on all wind speed readings from the past 2 minutes. -
Current Wind Speed
-
Learning Mode Icon
Disappears after weather forecast self calibration is complete. -
12 to 24 Hour Weather Forecast
Self-Calibrating Forecasting pulls data from your sensor to generate your personal forecast. -
Humidity Level Indicator
Indicates a high or low indoor humidity level. -
Current Indoor Temperature
Arrow icon indicates the direction the temperature is trending. -
Today Icon
Indicates viewing high/low records since midnight. -
Moon Phase
-
All-Time Icon
Indicates viewing All-Time records -
Icon
Indicates SET mode. -
Backlight Button
-
Intel-Time® Clock
Automatically updates itself for Daylight Saving Time. -
AUTO DIM Mode Indicator (page 8)
-
Display Low Battery Indicator
-
Date
-
Current Indoor Humidity
Arrow icon indicates the direction the humidity is trending. -
Storm Indicator
Indicates a rapid drop in pressure and probable storms. -
Barometric Pressure
Arrow icon indicates the direction the pressure is trending. -
Peak Wind Speed
Highest speed from past 60 minutes. -
Current Outdoor Humidity
Arrow icon indicates the direction the humidity is trending. -
Outdoor Sensor Signal Strength
-
Sensor Low Battery Indicator
BACK OF DISPLAY UNIT
-
Button
for setup preferences. -
Button
for setup preferences. -
Button
for setup preferences. -
Button
Press to access all-time high and low records. -
Battery Compartment
-
Plug-in for Power Adapter
-
A-B-C Switch
ID code that must match sensor’s A-B-C switch to ensure units synchronize. -
Reset Button
Full reset to factory defaults. -
Power Adapter
-
Battery Compartment Cover (not shown)
Setup
3-IN-1 Sensor Setup
(1) Set the A-B-C Switch
The A-B-C switch is located inside the battery compartment. It can be set to
A, B or C. However, you must select the same letter choices for both the
sensor and the display unit in order for the units to synchronize.
(2) Install or Replace Batteries
AcuRite recommends high quality alkaline or lithium batteries for the best
product performance. Heavy duty or rechargeable batteries are not recommended.
The 3-in-1 sensor requires lithium batteries in low temperature conditions.
Cold temperatures can cause alkaline batteries to function improperly. Use
lithium batteries in the 3-in-1 sensor for temperatures below -4ºF / -20ºC.
- Press the release lever and pull off the lower housing of the sensor.
- Remove the battery compartment cover. Take note of the A-B-C switch setting inside the battery compartment.
- Insert 4 x AA batteries into the battery compartment, as shown. Follow the polarity (+/-) diagram in the battery compartment.
- Replace the battery cover and lower housing of the sensor.
Display Unit Setup
(1) Set the A-B-C Switch
Locate the A-B-C switch inside the battery compartment. Set the A-B-C switch
to A, B or C. You must select the same letter choices for both the display
unit and the sensor in order for the units to synchronize.
(2) Install or Replace Backup Batteries (optional)
- Remove the battery compartment cover.
- Insert 3 x AAA alkaline batteries into the battery compartment, as shown. Follow the polarity (+/) diagram in the battery compartment.
- Replace the battery cover.
(3) Plug in Power Adapter
For the best performance, plug in the power adapter as the main power source
for this product.
PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY
AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.
BATTERY SAFETY: Clean the battery contacts and also those of the device prior
to battery installation. Remove batteries from equipment which is not to be
used for an extended period of time. Follow the polarity (+/-) diagram in the
battery compartment. Promptly remove dead batteries from the device. Dispose
of used batteries properly. Only batteries of the same or equivalent type as
recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose
of batteries in fire, as batteries may explode or leak. DO NOT mix old and new
batteries or types of batteries (alkaline/standard). DO NOT use rechargeable
batteries. DO NOT recharge non-rechargeable batteries. DO NOT short-circuit
the supply terminals.
Set the Time, Date & Units
Press the “ ” button, located on the front of the display unit, to enter SET MODE. Once in set mode, the preference you are currently setting will blink on the display.
To adjust the currently selected (flashing) item, press and release the “ ” or
“ ” buttons (press and HOLD to fast adjust).
To save your adjustments, press and release the “ ” button again to adjust the
next preference. The preference set order is as follows:
TIME ZONE DST (Daylight Savings Time ON or OFF)*
CLOCK HOUR
CLOCK MINUTE
CALENDAR MONTH
CALENDAR DATE
CALENDAR YEAR
TEMPERATURE UNITS (ºF or ºC)
PRESSURE UNITS (inHg or hPa)
WIND UNITS (MPH or KPH)
ox You will automatically exit SET MODE if no buttons are pressed for 10
seconds. Enter setup mode at any time by pressing the ” ” button.
- If you live in an area that observes Daylight Savings Time, DST should be set to ON, even if it is not currently Daylight Savings Time.
Display Backlight Settings
This weather station’s color display features three different lighting
settings: High (100%) brightness, Medium (60%) brightness and Low (30%)
brightness
Using battery power alone, the backlight is available momentarily for 10 seconds by pressing the “ ” button.
When display is powered with the power adapter, backlight remains on li at 100% brightness. Press “ ” button once to dim to 60% brightness; press again to dim to 30%, press a 3rd time to enter “AUTO DIM” mode. AUTO DIM appears below time.
Placement for Maximum Accuracy
AcuRite sensors are sensitive to surrounding environmental conditions. Proper placement of both the display unit and the sensor are critical to the accuracy and performance of this product.
Display Unit Placement
Place the display unit in a dry area free of dirt and dust. To ensure accurate
temperature measurement, place out of direct sunlight and away from heat
sources or vents. Display unit stands upright for tabletop use.
3-in-1 Sensor Placement
The 3-in-1 sensor is designed to remain outdoors all year long. Choose an open
location with no obstructions above or around the sensor for the most accurate
measurements.
Important Placement Guidelines
Display unit and sensor must be within 330 feet (100 m) of each other.
MAXIMIZE WIRELESS RANGE
Place units away from large metallic items, thick walls, metal surfaces, or
other objects that may limit wireless communication.
PREVENT WIRELESS INTERFERENCE
Place both units at least 3 feet (.9 m) away from electronic devices (TV,
computer, microwave, radio, etc.).
LOCATE AWAY FROM HEAT SOURCES
Position sensor away from heaters, air conditioners, chimneys, exhaust vents,
asphalt and concrete (surfaces that radiate heat).
LOCATE AWAY FROM HUMIDITY SOURCES
Avoid installing the sensor near pools, spas, or other bodies of water. Water
sources may impact humidity accuracy.
LOCATE AWAY FROM SPRINKLER HEADS
DO NOT install the sensor where it will be sprayed by a sprinkler system. This
may force water inside the sensor.
LOCATE AWAY FROM WIND OBSTRUCTIONS
DO NOT mount the sensor with obstructions around it. Consider a location that
is a wide open area, with few structures around to ensure accurate wind speed
measurement.
Visit us online to view installation photos and video, or learn more about AcuRite technology: www.AcuRite.com/3in1http://www.acurite.com/3in1?utm_source=00608-00607&utm_medium=qr&utm_campaign=Instructions
3-in-1 Sensor Installation Guidelines
INSTALLATION HEIGHT Mount the sensor at a minimum height of 5 feet (1.5 meters) off the ground, in an open area. Higher is better for wind measurements – the National Weather Service recommends 33 feet high!
MOUNTING OPTIONS The included mounting bracket is designed to screw directly onto wooden posts or surfaces that are 2″x4″ or larger. The sensor can also be mounted directly to 3/4″ steel or PVC pipe (available at hardware
LEVEL INSTALLATION Use a bubble level (not included) to ensure level installation for accurate wind measurement.
Top or Side Mount
- Insert the mounting base into the hole on the bottom of the sensor.
- Use one of the screws included in the hardware bag to fasten the lower sensor housing to the mounting base.
- Fasten mounting base to a post or railing using 2 screws.
Pipe Mount
- Insert pipe or similar item all the way into the hole on the bottom of the sensor. Note: Mounting base is not used.
- Use one of the screws included in the hardware bag to fasten the lower sensor housing securely to the pipe.
The 3-in-1 sensor is now ready to use.
Basic Setup is Complete
The 3-in-1 sensor will now synchronize with the display unit. It may take a
few minutes for synchronization to complete. If both or one of the units
appear to be functioning improperly, please refer to the troubleshooting
section.
Using The Weather Center
Learning Mode
Self-Calibrating Forecasting use a unique algorithm to analyze changes in
pressure over a time period (called Learning Mode) to determine your altitude.
After 14 days, the Learning Mode icon disappears from the display screen. At
this point, the self-calibrated pressure is tuned in to your location and the
unit is ready for superior weather prediction.
Weather Forecast
AcuRite patented Self-Calibrating Forecasting provides your personal forecast
of weather conditions for the next 12 to 24 hours by collecting data from the
sensor in your backyard. It generates a forecast with pinpoint accuracy –
personalized for your exact location.
View the complete list of icons atwww.AcuRite.com/acurite- icons
Barometric Pressure
Subtle variations in barometric pressure greatly impact the weather. This
weather center displays the current pressure with an arrow icon to indicate
the direction the pressure is trending (FALLING, STEADY, or RISING).
Moon Phase
Track the phases of the moon, conveyed through simple lunar phase icons:
Wind Speed
The Wind Speed area of the display features the CURRENT speed, as well as
the AVERAGE and PEAK wind speeds. AVERAGE wind speeds are based on all wind
speed readings from the last 2 minutes. PEAK wind speed is the highest speed
recorded from the past 60 minutes.
High & Low Records
Today’s high and low records are displayed for indoor and outdoor temperature,
humidity and wind speed. Today’s records automatically clear at 12:00am
midnight every day.
To manually clear all of today’s LOW recorded values, press and hold the “ ” button for 2 seconds. Dashes display to confirm you have cleared the LOW records.
To manually clear all of today’s HIGH recorded values, press and hold the ” ” button for 2 seconds. Dashes display to confirm you have cleared the HIGH records.
Press the ” ” button to cycle through the all-time high and low recorded values (one record is shown at a time) for outdoor and indoor temperature and humidity. Located near the clock, a date and time stamp are shown for when each value was recorded. You will automatically exit all-time records if no buttons are pressed for 5 seconds.
To manually clear an all-time LOW record, press and hold the “ ” button for 2 seconds while viewing the record you wish to clear. Dashes display to confirm you have cleared the record.
To manually clear an all-time HIGH record, press and hold the “ ” button for 2 seconds while viewing the record you wish to clear. Dashes display to confirm you have cleared the record.
Troubleshooting
If your AcuRite product does not operate properly after trying the troubleshooting steps, visit www.AcuRite.com or call 877-221-1252 for assistance.
Care & Maintenance
Display Unit Care
Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives. Keep
away from dust, dirt and moisture. Clean ventilation ports regularly with a
gentle puff of air.
3-in-1 Sensor Care
Clean the Sensor
Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives.
Insect Prevention
Insects may cause obstructions and interrupt data by nesting in or on the
3-in-1 sensor. To limit this problem, spray sensor housing with a household
insect repellent. Note: Insect repellent should not be sprayed on the internal
components or into the sensor. Consult insect repellent instructions prior to
use.
Snow & Freezing Weather
The 3-in-1 sensor will not be damaged by freezing conditions.
Clean the Wind Anemometer
Remove foreign matter from the outside of the sensor for free movement of the
wind anemometer. If needed, use a small amount of spray lubricant, clear
silicone or graphite powder on the anemometer for improved movement. Note:
Spray lubricant, clear silicone or graphite powder should not be sprayed on
the internal components or into the sensor.
Calibration
The indoor / outdoor temperature and humidity readings, and barometric pressure can be calibrated on the display unit to improve accuracy. Calibration can improve accuracy when sensor placement or environmental factors impact the data accuracy.
- To access calibration mode, press AND HOLD the “ “, ” “, and ” ” buttons simultaneously for at least 5 seconds.
- To adjust the currently selected (flashing) item, press and release the “ ” or “ ” buttons to calibrate the data value higher or lower from the actual reading.
- To save your adjustments, press and release the “ ” button to adjust the next preference. The ” ” icon will remain illuminated next to calibrated values.
The preference set order is as follows:
OUTDOOR TEMPERATURE
OUTDOOR HUMIDITY
INDOOR TEMPERATURE
INDOOR HUMIDITY
BAROMETRIC PRESSURE (must be set to MANUAL mode to calibrate)
To change from AUTO to MANUAL pressure mode and vice versa, press AND HOLD the ” ” button for at least 10 seconds. The display indicates the current pressure mode selected, “AUTO” or “MANUAL”.
After 20 seconds of inactivity, the display will save the adjustments and exit
calibration mode. Note: Calibrations will be erased if the display is reset or
if batteries are removed and the power adapter is unplugged.
Replace Intelli-Time® Clock Battery
Intelli-Time technology is powered by a pre-installed coin-cell battery that stores the time and date settings. The battery has a shelf life of several years. To replace the Intelli-Time battery:
- Locate the coin cell battery compartment door on the back of the display unit. Unscrew and remove the compartment cover.
- Insert 1 x CR2032 coin cell battery into the battery compartment, as shown. Install battery with “+” positive terminal facing OUT.
- Screw in the battery cover.
Specifications
FCC Information
This device complies with part 15 of FCC rules. Operation is subject to the
following two conditions:
1- This device may NOT cause harmful interference, and
2- This device must accept any interference received, including interference
that may cause undesired operation. WARNING: Changes or modifications to this
unit not expressly approved by the party responsible for compliance could void
the user’s authority to operate the equipment. NOTE: This equipment has been
tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC rules. These limits are designed to provide
reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
NOTE: The manufacturer is not responsible for any radio or TV interference
caused by unauthorized modifications to this equipment. Such modifications
could void the user authority to operate the equipment. This device complies
with Industry Canada license-exempt RSS standard(s). Operation is subject to
the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference received, including interference
that may cause undesired operation of the device.
Customer Support
AcuRite customer support is committed to providing you with best-in-class service. For assistance, please have the model number of this product available and contact us in any of the following ways:
24/7 support at www.AcuRite.com
- Installation Videos
- Register your Product
- Instruction Manuals
- Support User Forum
- Replacement Parts
- Submit Feedback & Ideas
Warranty
Limited One Year Warranty
At AcuRite, we proudly uphold our commitment to quality technology. Chaney
Instrument Co. warrants that all products it manufactures to be of good
material and workmanship, and to be free of defects when properly installed
and operated for a period of one year from the date of purchase.
We recommend that you visit us at www.AcuRite.com for the fastest way to register your product. However, product registration does not eliminate the need to retain your original proof of purchase in order to obtain warranty benefits.
Chaney Instrument Co. warrants that all products it manufactures to be of good material and workmanship, and to be free of defects when properly installed and operated for a period of one year from the date of purchase. Remedy for breach of this warranty is limited to repair or replacement of the defective item(s). Any product which, under normal use and service, is proven to breach the warranty contained herein within ONE YEAR from date of sale will, upon examination by Chaney, and at its sole option, be repaired or replaced by Chaney. Transportation costs and charges for returned goods shall be paid for by the purchaser. Chaney hereby disclaims all responsibility for such transportation costs and charges. This warranty will not be breached, and Chaney will give no credit for products it manufactures which have received normal wear and tear, been damaged (including by acts of nature), tampered, abused, improperly installed, damaged in shipping, or repaired or altered by others than authorized representatives of Chaney.
The above-described warranty is expressly in lieu of all other warranties, express or implied, and all other warranties are hereby expressly disclaimed, including without limitation the implied warranty of merchantability and the implied warranty of fitness for a particular purpose. Chaney expressly disclaims all liability for special, consequential or incidental damages, whether arising in tort or by contract from any breach of this warranty. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Chaney further disclaims all liability from personal injury relating to its products to the extent permitted by law. By acceptance of any of Chaney’s products, the purchaser assumes all liability for the consequences arising from their use or misuse. No person, firm or corporation is authorized to assume for Chaney any other liability in connection with the sale of its products. Furthermore, no person, firm or corporation is authorized to modify or waive the terms of this paragraph, and the preceding paragraph, unless done in writing and signed by a duly authorized agent of Chaney. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
For in-warranty claims: Chaney Instrument Co. | 965 Wells St. | Lake Geneva, WI 53147
It’s more than accurate, it’s ACURITE.
AcuRite offers an extensive assortment of precision instruments, designed to provide you with information you can depend on to Plan your day with confidence™.
©Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copyrights are the property of their respective owners. AcuRite uses patented technology. Visit www.AcuRite.com/patents for details.
Printed in China
01604 INST 070314
Documents / Resources
|
ACURITE 01604 Weather Center with Color Digital
Display
[pdf] Instruction Manual
01604, Weather Center with Color Digital Display
---|---
References
- Home
- AcuRite Weather Monitoring | #1 Weather Station Brand in North America
- 3-in-1 Weather Sensor Installation | AcuRite
- Icon Definitions and Terminology | AcuRite
- Acurite GDPR Notice
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>