ROBUS RDR6D2W-11 LED Recess Light Fitting Dimmable Draco Installation Guide

June 6, 2024
ROBUS

DRACO 6W LED DIM TO WARM 3000K TO 2000K AND
CCT2 (3000K AND 2000K) DOWNLIGHT, MATT WHITE
RDR6D2W-11
Installation Guide

PLEASE READ THE INSTRUCTIONS BEFORE COMMENCING INSTALLATION AND RETAIN THEM FOR FUTURE REFERENCES.
! Electrical products can cause death or injury, or damage to property. If in any doubt about the installation or use of this product, consult a competent electrician
Note:
Product technical information and specification may change over time without prior notification. For the latest technical information please visit our web site www.robus.com or robusdirect.com

-20°C < Ta < +40°C, 220-240V ~ 50/60Hz, Class II, IP65
Suitable for mounting on a normally flammable surface. Dimmable with selected leading and trailing edge dimmers
See website for compatible dimmer list: www.robus.com

Installation

  1. Ensure mains supply is switched off before commencing work.

  2. Before cutting, ensure that the hole does not impinge on joists, pipework, cables or other building services.

  3. This luminaire requires a round hole of Ø70mm to be cut into the ceiling for correct installation.

  4. Connect supply: L – Brown, N –Blue.

  5. Move the switch on the driver to select color temperature: 2000K, 3000Kor 2000K-3000K. Change color temperature via dimmer when the 3000K-2000K option is selected. WARNING: DO NOT CHANGE CCT on diver WHEN THE
    THE FITTING IS ON!!

  6. Hold retention spring vertically against the heat sink, push fitting through the cut-out until the springs come down on the upper side of the plasterboard.
    Ensure that the fitting is secure and the bezel is tight against the ceiling.

The luminaire may be covered with mineral wool thermal insulation or glass wool thermal insulation of the type described in EN 13162:2015. This applies to both solid and blows over loose fill. If the installer wishes to use cellulose-based loose insulation or foam spray over insulation, they must use a bell-shaped insulation cover over the luminaire. Although the fitting may be safely covered with insulation material, we recommend that the luminaire be abutted to but not covered with insulation material in order to maximize the lifetime of the luminaire. Luminaire lifetime can be maximized by maintaining as low an operating temperature as possible.
Market Surveillance:
LS Code’ of energy efficiency Class F. RDR6D2W-LS
Disconnect fitting from the driver.

Information for the Product user:

  1. Please note the requirement to dispose of Waste Electrical & Electronic Equipment separately from household waste (WEEE marked with crossed-out wheelie bin symbol).
  2. Please consider your role in contributing to re-use and recycling by returning this product at end of life to a collection center for waste electrical equipment or a Civic Amenity site, or to a retail outlet from which you are purchasing a replacement.
  3. This equipment may contain substances that are hazardous to health and the environment if disposed of carelessly. It is important that it is separated from normal household waste and recycled in the WEEE chain
  4. The “crossed out wheelie bin symbol” on a product indicates this equipment must not be disposed of in normal household waste, but should be disposed of according to local WEEE regulations

The Installation must be carried out by a qualified electrician

L.E.D lighting & Electrical Distribution Group UC
IRE: Nangor Road, Dublin 12, D12 E7VP, Ireland
UK: Bracknell Enterprise & Innovation Hub, Ocean
House, 12th Floor, The Ring, Bracknell,
Berkshire RG12 1AX, UK

Tel: +353 1 7099000
Fax: +353 1 7099060
Email: info@robus.com
Website: www.robus.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ROBUS User Manuals

Related Manuals