ROBUS RUL050730-01 Ultimum 5-7W Dual Wattage IP65 Fire Rated Downlight Instructions

June 6, 2024
ROBUS

ROBUS RUL050730-01 Ultimum 5-7W Dual Wattage IP65 Fire Rated Downlight

INSTALLATION INSTRUCTION

PLEASE READ INSTRUCTION BEFORE COMMENCING INSTALLATION AND RETAIN FOR FUTURE REFERENCES. Electrical products can cause death or injury, or damage to property. If in any doubt about the installation or use of this product, consult a competent electrician

Note:
Product technical information and specification may change over time without prior notification. For the latest technical information please visit our web site www.robus.com or robusdirect.com -20°C < Ta < +40°C, 220-240V ~ 50/60Hz, Class I, IP65 Suitable for mounting on a normally flammable surface. See website for compatible dimmer list: www.robus.com

Installation

  1.  Ensure mains supply is switched off before commencing work.
  2.  It is possible to change the trims to a different colour
  3.  Before cutting, ensure that the hole does not impinge on joists, pipe work, cables or other building services.
  4.  This luminaire requires a round hole Ø72mm to be cut into the ceiling for correct installation.
  5.  Connect supply: L – Brown, N –Blue and Yellow/Green – Earth
  6.  Select wattage (7W or 5W) by moving the switch on the back of the fitting as per fig. 4 Note: Do not change wattage when the fitting is on!
  7.  Hold retention spring vertically against the heat sink, push fitting through the cut-out until the springs come down on the upper side of the plasterboard. Ensure that the fitting is secure and the bezel is tight against the ceiling.

The luminaire may be covered with mineral wool thermal insulation of the type described in EN 13162:2015. If the installer wishes to use loose insulation or foam spray over insulation, they must use a bell shaped insulation cover over the luminaire. Although the fitting may be safely covered with insulation material, we recommend that the luminaire be abutted to but not covered with insulation material in order to maximise the lifetime of the luminaire. Luminaire lifetime can be maximised by maintaining as low an operating temperature as possible. Trims: RULTRIM-03: Chrome; RULTRIM-10: Matt Black; RULTRIM-13: Brushed Chrome Downlights listed are tested in 30, 60 and 90 minute ceiling types using EN 1365-2.2014 test method. For a list of tested ceiling types please contact Robus Technical Department. Minimum spacing of 500mm between downlights must be maintained or no more than 2 downlights within a 1m² area.

Information for the Product user

  1.  Please note the requirement to dispose of Waste Electrical & Electronic Equipment separately from household waste (WEEE marked with crossed out wheelie bin symbol).
  2.  Please consider your role in contributing to re-use and recycling by returning this product at end of life to a collection centre for waste electrical equipment or a Civic Amenity site, or to a retail outlet from which you are purchasing a replacement.
  3.  This equipment may contain substances that are hazardous to health and the environment if disposed of carelessly. It is important that it is separated from normal household waste and recycled in the WEEE chain
  4.  The “crossed out wheelie bin symbol” on a product indicates this equipment must not be disposed of in normal household waste, but should be disposed of according to local WEEE regulations

The Installation must be carried out by a qualified electrician

Email: info@robus.com/Website: www.robus.com

References

Read User Manual Online (PDF format)