FA147C Wiring Uplink’s 5530M Cellular Communicators Instruction Manual

June 1, 2024
Uplink

FA147C Wiring Uplink’s 5530M Cellular Communicators

FA147C-Wiring-Uplink’s-5530M-Cellular-Communicators-
PRODUCT

Product Information

  • Specifications:
    • Product: Honeywell FA147C/FA148C
    • Compatible with: Uplink’s 5530M Cellular Communicators
    • Alarm Panel Type: Honeywell FA147C/FA148C

Product Usage Instructions

  • Wiring the 5530M Communicators to Honeywell FA147C/FA148C:
    • Ensure power is off to the alarm panel.
    • Identify the communication terminals on the FA147C/FA148C panel.
    • Connect the appropriate wires from the 5530M communicator to the designated terminals on the panel.
  • Programming the Honeywell FA147C/FA148C Alarm Panel via the Keypad:
    • Access programming mode on the alarm panel keypad.
  • Enable Contact ID reporting by entering the following sequence:
    • Keypad Display 20
    • Keypad Entry: 4112,8,00 41 123456 43 1234 45 1 46 77 65 1 66 11 70 1 99

FAQs

  • Q: How do I know if the wiring is correct?
    • A: You can perform a communication test after wiring to ensure proper connectivity.
  • Q: Can I use other brands of communicators with the FA147C/FA148C panels?
    • A: It is recommended to use Uplink’s 5530M Cellular Communicators for compatibility and optimal performance.

INTRODUCTION

CAUTION:

  • It is advised that an experienced alarm installer programs the panel as further programming may be required to ensure proper performance and use of the full functionality.
  • Do not route any wiring over the circuit board.
  • Full panel testing, and signal confirmation, must be completed by the installer.

NEW FEATURE:

  • For 5530M Communicators, the status of the panel can be retrieved not only from the status PGM but now also from the Open/Close reports from the dialler.
  • Therefore, wiring the white wire and programming the status PGM of the panel is optional. Wiring the white wire is necessary only if the Open/Close reporting is disabled.

IMPORTANT NOTE:

  • The Open/Close reporting needs to be enabled during the initial pairing procedure.

Wiring Communicators

Wiring the 5530M communicators to Honeywell FA147C/ FA148C

FA147C-Wiring-Uplink’s-5530M-Cellular-Communicators-
FIG-1

Keypad Display

Programming the Honeywell FA147C/ FA148C Alarm Panel via the Keypad

Enable Contact ID reporting:

Keypad Display Keypad Entry Action Description
  4112,8,00 To enter the programming menu.
20 *41 To go to the primary phone setting.
  123456* Enter phone number (123456 is an example) * to save.
  *43 To go to a primary account number.
  1234 Enter the account number (1234 is an example) * to save.
  *45 To go to the phone system menu.
  1 Press 1 to select tone dialling.
  46 Choose Report Format.
  77 To select Ademco Contact ID reporting.
  *65 To go to Open Report code.
  1 To enable Open report code.
  *66 To Arm Away/Stay Rpt Code.
  11 To enable Away/Stay ARM reporting code.
  *70 To go to Alarm/Restore reporting code.
  1 To enable alarm/Restore reporting code.
  *99 To exit and save.

Wiring and Programming Uplink Communicators to Honeywell FA147C/ FA148C

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals