Product Usage Instructions

Enabling Contact ID Reporting

  1. Enter Programming Mode: *85555
  2. Access Third System Options: 015
  3. Disable TLM: Toggle Option 7# to OFF
  4. Set the First Phone Number: 301, Enter any number followed by 6 (e.g., 1234566)
  5. Set System Account Code: 310, Enter the account number followed by 66 (e.g., 123466)
  6. Configure Communicator Alarm Format: 350, Enter data 03030303 for Contact ID
  7. Set Phone 1 Communicator Call Direction: 351, Toggle Option 1# to ON
  8. Enable Open/Close Reports: 367, Toggle Option 1# to ON
  9. Configure First Communication Options: 380, Toggle Option 1# to ON, 3 to OFF
  10. Configure Second Communication Options: 381, Toggle Option 7# to OFF for automatic reporting

Programming Key-switch Zone and Output

  1. Enter Programming Mode: *85555
  2. Set Key-switch Zone: Enter Section 206, Toggle Option 1#
  3. Program Output: Enter Section 013, Toggle Option 1#
  4. Set Communication Options: Enter Section 133, Toggle Option 9, then Enter Data XX (specific instructions needed)

FAQ

  • Q: How do I enter Programming Mode?
  • A: To enter Programming Mode, use the code *85555 on the keypad.
  • Q : How can I disable TLM?
  • A : To disable TLM, access the Third System Options (015) and toggle Option 7# to OFF.
  • Q: What is the default account code for System Account Code?
  • A : The default account code is typically set as ‘1234’ followed by *66 in hex.
  • Q: How do I configure the Communicator Alarm Format?
  • A : Access menu 350 and enter ‘03030303’ to set all four phone lines for Contact ID.

CAUTION

  • It is advised that an experienced alarm installer programs the panel as further programming may be required to ensure proper performance and use of the full functionality.
  • Do not route any wiring over the circuit board.
  • Full panel testing, and signal confirmation, must be completed by the installer.

FEATURE

NEW FEATURE: For 5530M Communicators, the status of the panel can be retrieved not only from the status PGM but now also from the Open/Close reports from the dialler.
IMPORTANT NOTE: The Open/Close reporting needs to be enabled during the initial pairing procedure.

Wiring the Uplink 5530M to DSC 9045/9047

Programming the DSC 9045/9047 Alarm Panel via the Keypad

Enable Contact ID reporting

Keypad Display Keypad Entry Action description
Enter Section: *85555 To enter in Programming mode.
Enter Section: 015 To enter the menu “Third System options”.
Toggle Option: 7# Option 7 must be OFF (TLM disabled).
Enter Section: 301 To enter the menu” First phone number”.
DFFFFF 1234566# Enter an actual or non-existing number (any number will

do, 123456 is an example) followed by 6 (F in hex).
Enter Section:| 310| To enter the menu “System account code”.
Enter data:| 123466| Enter a 4-digit account number to receive the events from (1234 is an example) and close it with 66 in hex.
Enter Section:| 350| To enter the “Communicator Alarm Format” options.
Enter Data:| 03030303| 03 is for Contact ID (03030303 is to set all 4 phone lines).
Enter Section:| 351| To program phone 1 communicator call direction.
Toggle Option:| 1#| Toggle 1 to ON for alarms (it has to appear on screen).
Enter Section:| 367| Open/Close Communicator Call directions.
Toggle Option:| 1#| Toggle 1 to ON to enable Open/Close reports (it has to appear on screen).
Enter Section:| 380| Enter First Communication Options.
Toggle Option:| 1#| Toggle 1 to ON, 3 to off to enable communications.
Enter Section:| 381| Enter Second Communication Options.

Toggle Option:

|

7#

| Toggle 7 to OFF to enable automatic reporting.

To manually program the reporting codes in menu 381, enable option 7 to ON and then set the desired reporting codes in menus 320 to 348.

| #| Exit Programming mode.

Program Key-switch zone and output

Keypad Display Keypad Entry Action Description
Enter Section: *85555 To enter in Programming mode.
Enter Section 206 Enter Zone Assignment
Toggle Option 1# Toggle option 1 to ON to enable the Keyswitch zone.
Enter Section 013 Enter First System Options (to select I/O as Input or

PGM).
Toggle Option| 1#| When the panel is defaulted press the toggle buttons until 1 is ON and 2 is OFF.
Enter Section| 133| Enter I/O 1 Programming.
Toggle Option| 9| Press 9 to move to options 9‐16.
Toggle Option| 7#| Make sure that option 15 is selected (shows as 7).

This standard mode of operation REQUIRES a resistor across the STC.

Enter Section:| 009| Enter I/O Programming.
Enter Data: XX| 22| Enter 22 to program zone Type Keyswitch for I/O 1.
Enter Data: XX| 05| Enter 05 to program Armed Status on I/O 2.
| #| Exit Programming mode.