Uplink 5530M Universal Dual Sim Alarm Instruction Manual
- June 1, 2024
- Uplink
Table of Contents
Uplink 5530M Universal Dual Sim Alarm
Product Information
Specifications
- Product Name: DSC Alexor
- Compatibility: Works with Uplink’s 5530M Cellular Communicators
- Functionality: Alarm Panel Programming and Communication
Product Usage Instructions
Wiring Uplink’s 5530M Cellular Communicators to DSC Alexor
- Connect the 5530M communicator to the DSC Alexor according to the wiring diagram provided.
- Ensure all connections are secure and properly insulated.
Programming the DSC Alexor Alarm Panel via Keypad
- To enable Contact ID reporting:
- Enter *85555 to enter Programming mode.
- Enter 015 to access the Third System options.
- Toggle Option 7# to disable TLM (Option 7 must be OFF).
- Enter 301 to access the First phone number menu.
- Enter the desired phone number followed by 6 in hex format.
- Continue with Sections 310, 350, 351, 367, 380, and 381 following the provided instructions.
- Program Key-switch zone and output:
- Enter *85555 followed by the provided sequence of actions to program the key-switch zone and output.
- Program the Panel for Upload/Download (UDL):
- Enter *8 + Installer Code 401 to access the programming menu (the default installer code is 5555).
- Adjust settings in Sections 403, 404, 405, and 406 as instructed for UDL functionality.
FAQ
-
Q: How do I reset the DSC Alexor Alarm Panel to factory settings?
A: To reset the panel to factory settings, enter the default installer code and navigate to the reset option in the programming menu. -
Q: What should I do if I encounter communication issues with the Uplink Communicators?
A: Check the wiring connections, ensure proper configuration following the manual, and contact customer support for further assistance.
CAUTION:
- It is advised that an experienced alarm installer programs the panel as further programming may be required to ensure proper performance and use of the full functionality.
- Do not route any wiring over circuit board.
- Full panel testing, and signal confirmation, must be completed by the installer.
NEW FEATURE: For 5530M Communicators, the status of the panel can be
retrieved not only from the status PGM but now also from the Open/Close
reports from the dialler.
IMPORTANT NOTE: The Open/Close reporting needs to be enabled during the
initial pairing procedure.
Wiring the 5530M communicators to DSC Alexor
Wiring the 5530M device with UDM to DSC Alexor for remote upload/download
Programming the DSC Alexor Alarm Panel via the Keypad
Enable Contact ID reporting:
Keypad Display | Keypad Entry | Action description |
---|---|---|
Enter Section: | *85555 | To enter in Programming mode. |
Enter Section: | 015 | To enter menu “Third System options”. |
Toggle Option: | 7# | Option 7 must be OFF (TLM disabled). |
Enter Section: | 301 | To enter menu” First phone number”. |
DFFFFF | 1234566# | Enter actual or non-existing number (any number will do, |
123456 is an example) followed by 6 (F in hex).
Enter Section:| 310| To enter menu “System account code”.
Enter data:| 123466| Enter 4-digit account number to receive the events from
(1234 is an example) and close it with 66 in hex.
Enter Section:| 350| To enter “Communicator Alarm Format” options.
Enter Data:| 03030303| 03 is for Contact ID (03030303 is to set all 4 phone
lines).
Enter Section:| 351| To program phone 1 communicator call direction.
Toggle Option:| 1#| Toggle 1 to ON for alarms (it has to appear on screen).
Enter Section:| 367| Open/Close Communicator Call directions.
Toggle Option:| 1#| Toggle 1 to ON to enable Open/Close reports (it has to
appear on screen).
Enter Section:| 380| Enter First Communication Options.
Toggle Option:| 1#| Toggle 1 to ON, 3 to off to enable communications.
Enter Section:| 381| Enter Second Communication Options.
Toggle Option:
|
7#
| Toggle 7 to OFF to enable automatic reporting.
To manually program the reporting codes in the menu 381, enable option 7 to ON and then set the desired reporting codes in menus 320 to 348.
| #| Exit Programming mode.
Program Key-switch zone and output:
Keypad Display | Keypad Entry | Action Description |
---|---|---|
Enter Section: | *85555 | To enter in Programming mode. |
Enter Section | 206 | Enter Zone Assignment |
Toggle Option | 1# | Toggle option 1 to ON to enable the Keyswitch zone. |
Enter Section | 013 | Enter First System Options (to select I/O as Input or |
PGM).
Toggle Option| 1#| When the panel is defaulted press the toggle buttons until
1 is ON and 2 is OFF.
Enter Section| 133| Enter I/O 1 Programming.
Toggle Option| 9| Press 9 to move to options 9‐16.
Toggle Option| 7#| Make sure that option 15 is selected (shows as 7).
This standard mode of operation REQUIRES a resistor across the STC.
Enter Section:| 009| Enter I/O Programming.
Enter Data: XX| 22| Enter 22 to program zone Type Keyswitch for I/O 1.
Enter Data: XX| 05| Enter 05 to program Armed Status on I/O 2.
| #| Exit Programming mode.
Programming the DSC Alexor Alarm Panel via the Keypad for remote
Upload/Download (UDL)
Program the Panel for Upload/Download (UDL):
Display | Keypad Entry | Action Description |
---|---|---|
Date / Time | *8 + Inst. Code | Enter the programming menu. The default |
installer code is “5555”.
Enter section| 401| First downloading options toggle menu
Toggle option| 1,3,6#| 1 and 3 should be disabled. 6 should be enabled. Press
to exit.
Enter section| 403| DLS downloading access code.
Enter Hex Data| 915500#| Set this field’s value to its default. Press # to
exit.
Enter section| 404| Panel ID code.
Enter Hex Data| 915500#| Set this field’s value to its default. Press # to
exit.
Enter section| 405| Double call timer address
Enter Data| 000#| Disable double call.
Enter section| 406| Number of rings address
Enter Data| 001#| Set the panel to answer on the first ring.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>