Uplink 5530M Universal Dual Sim Alarm Instruction Manual

June 1, 2024
Uplink

Uplink 5530M Universal Dual Sim Alarm

Product Information

Specifications

  • Product Name: DSC Alexor
  • Compatibility: Works with Uplink’s 5530M Cellular Communicators
  • Functionality: Alarm Panel Programming and Communication

Product Usage Instructions

Wiring Uplink’s 5530M Cellular Communicators to DSC Alexor

  1. Connect the 5530M communicator to the DSC Alexor according to the wiring diagram provided.
  2. Ensure all connections are secure and properly insulated.

Programming the DSC Alexor Alarm Panel via Keypad

  1. To enable Contact ID reporting:
  2. Enter *85555 to enter Programming mode.
  3. Enter 015 to access the Third System options.
  4. Toggle Option 7# to disable TLM (Option 7 must be OFF).
  5. Enter 301 to access the First phone number menu.
  6. Enter the desired phone number followed by 6 in hex format.
  7. Continue with Sections 310, 350, 351, 367, 380, and 381 following the provided instructions.
  8. Program Key-switch zone and output:
  9. Enter *85555 followed by the provided sequence of actions to program the key-switch zone and output.
  10. Program the Panel for Upload/Download (UDL):
  11. Enter *8 + Installer Code 401 to access the programming menu (the default installer code is 5555).
  12. Adjust settings in Sections 403, 404, 405, and 406 as instructed for UDL functionality.

FAQ

  • Q: How do I reset the DSC Alexor Alarm Panel to factory settings?
    A: To reset the panel to factory settings, enter the default installer code and navigate to the reset option in the programming menu.

  • Q: What should I do if I encounter communication issues with the Uplink Communicators?
    A: Check the wiring connections, ensure proper configuration following the manual, and contact customer support for further assistance.

CAUTION:

  • It is advised that an experienced alarm installer programs the panel as further programming may be required to ensure proper performance and use of the full functionality.
  • Do not route any wiring over circuit board.
  • Full panel testing, and signal confirmation, must be completed by the installer.

NEW FEATURE: For 5530M Communicators, the status of the panel can be retrieved not only from the status PGM but now also from the Open/Close reports from the dialler.
IMPORTANT NOTE: The Open/Close reporting needs to be enabled during the initial pairing procedure.

Wiring the 5530M communicators to DSC Alexor

Uplink-5530M-Universal-
Dual-Sim-Alarm-FIG- \(1\)

Wiring the 5530M device with UDM to DSC Alexor for remote upload/download Uplink-5530M-Universal-Dual-Sim-Alarm-FIG- \(2\)

Programming the DSC Alexor Alarm Panel via the Keypad

Enable Contact ID reporting:

Keypad Display Keypad Entry Action description
Enter Section: *85555 To enter in Programming mode.
Enter Section: 015 To enter menu “Third System options”.
Toggle Option: 7# Option 7 must be OFF (TLM disabled).
Enter Section: 301 To enter menu” First phone number”.
DFFFFF 1234566# Enter actual or non-existing number (any number will do,

123456 is an example) followed by 6 (F in hex).
Enter Section:| 310| To enter menu “System account code”.
Enter data:| 123466| Enter 4-digit account number to receive the events from (1234 is an example) and close it with 66 in hex.
Enter Section:| 350| To enter “Communicator Alarm Format” options.
Enter Data:| 03030303| 03 is for Contact ID (03030303 is to set all 4 phone lines).
Enter Section:| 351| To program phone 1 communicator call direction.
Toggle Option:| 1#| Toggle 1 to ON for alarms (it has to appear on screen).
Enter Section:| 367| Open/Close Communicator Call directions.
Toggle Option:| 1#| Toggle 1 to ON to enable Open/Close reports (it has to appear on screen).
Enter Section:| 380| Enter First Communication Options.
Toggle Option:| 1#| Toggle 1 to ON, 3 to off to enable communications.
Enter Section:| 381| Enter Second Communication Options.

Toggle Option:

|

7#

| Toggle 7 to OFF to enable automatic reporting.

To manually program the reporting codes in the menu 381, enable option 7 to ON and then set the desired reporting codes in menus 320 to 348.

 | #| Exit Programming mode.

Program Key-switch zone and output:

Keypad Display Keypad Entry Action Description
Enter Section: *85555 To enter in Programming mode.
Enter Section 206 Enter Zone Assignment
Toggle Option 1# Toggle option 1 to ON to enable the Keyswitch zone.
Enter Section 013 Enter First System Options (to select I/O as Input or

PGM).
Toggle Option| 1#| When the panel is defaulted press the toggle buttons until 1 is ON and 2 is OFF.
Enter Section| 133| Enter I/O 1 Programming.
Toggle Option| 9| Press 9 to move to options 9‐16.
Toggle Option| 7#| Make sure that option 15 is selected (shows as 7).

This standard mode of operation REQUIRES a resistor across the STC.

Enter Section:| 009| Enter I/O Programming.
Enter Data: XX| 22| Enter 22 to program zone Type Keyswitch for I/O 1.
Enter Data: XX| 05| Enter 05 to program Armed Status on I/O 2.
 | #| Exit Programming mode.

Programming the DSC Alexor Alarm Panel via the Keypad for remote Upload/Download (UDL)
Program the Panel for Upload/Download (UDL):

Display Keypad Entry Action Description
Date / Time *8 + Inst. Code Enter the programming menu. The default

installer code is “5555”.
Enter section| 401| First downloading options toggle menu
Toggle option| 1,3,6#| 1 and 3 should be disabled. 6 should be enabled. Press

to exit.

Enter section| 403| DLS downloading access code.
Enter Hex Data| 915500#| Set this field’s value to its default. Press # to exit.
Enter section| 404| Panel ID code.
Enter Hex Data| 915500#| Set this field’s value to its default. Press # to exit.
Enter section| 405| Double call timer address
Enter Data| 000#| Disable double call.
Enter section| 406| Number of rings address
Enter Data| 001#| Set the panel to answer on the first ring.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Uplink User Manuals

Related Manuals