Uplink SP4000 Paradox Central Alarm User Guide

June 1, 2024
Uplink

Uplink SP4000 Paradox Central Alarm

Uplink-SP4000-Paradox-Central-Alarm-PRODUCT

Specifications

  • Product: Paradox SP4000
  • Compatibility: Uplink’s Cellular Communicators
  • Features: Contact ID reporting, keyswitch arm/disarm, PGM output delays

Product Usage Instructions

Follow the wiring instructions provided by both Uplink and Paradox to connect the communicators.

  1. Enable Contact ID reporting:
  2. Enter 0000 800
  3. Enter 1, 2, 8, 6, Enter
  4. Enter 1,5, 3,7
  5. Clear 810 4,4 811 1234 Clear 815 123456, Enter
  6. Enable keyswitch arm/disarm and status output:
  7. Enter 0000 001 26, 1
  8. Enter, Enter Clear 220 02 12, 01
  9. Enter, Clear
  10. 221 02 11, 01 Enter, Clear 281 000 Enter, Clear Clear

FAQ

  • Q: How do I wire the 5530M communicators to the Paradox SP4000?
  • A: Refer to the wiring instructions provided in the user manual for detailed steps on connecting the communicators.
  • Q: How do I exit programming mode on the Paradox SP4000?
  • A: To exit programming mode, follow the specific exit sequence provided in the manual or press the designated exit key combination on the keypad.

CAUTION

  • It is advised that an experienced alarm installer programs the panel as further programming may be required to ensure proper performance and use of the full functionality.
  • Do not route any wiring over a circuit board.
  • Full panel testing, and signal confirmation, must be completed by the installer.

NEW FEATURE: For 5530M Communicators, the status of the panel can be retrieved not only from the status PGM but now also from the Open/Close reports from the dialler. Therefore, wiring the white wire and programming of the status PGM of the panel is optional.
IMPORTANT NOTE: The Open/Close reporting needs to be enabled during the initial pairing procedure.

Wiring

Wiring the 5530M communicators to Paradox SP4000

Uplink-SP4000-Paradox-Central-Alarm-FIG-1

Programming the Paradox SP4000 Alarm Panel via the Keypad
Enable Contact ID reporting:

LED indication on Keypad Keypad Entry Action Description
  Enter, 0000 To enter Programming mode
  800 To go to 1st Dialer Options menu

Buttons 1,2,8 – Dim, Button 6 – Lit

|

1, 2, 8,     6,

Enter

| Toggle options menu -> press keypad buttons to select ON/OFF (ON – lit, OFF- dim). 1,2,8 must be OFF and 6 must be ON. Enter to save and go to the next menu – 801 – 2nd Dialer Options
Button 1 – Dim| 1| For 801 -> 1 must be OFF, “Enter” to save and go to 802
Buttons 1,5 – Lit, Buttons 3,7 – Dim|

1,5, 3,7

| For 802 -> Options, 1,5 must be ON, 3,7 must be OFF, “Enter” to save and go to 803 (802,803,804 are for “Event call direction”)
Buttons 1,5 – Lit, Buttons 3,7 – Dim| 1,5, 3,7| For 803 -> Again, Options 1,5 must be ON, 3,7 must be OFF,

“Enter” to save and go to 804

Button 1 – Lit| 1| Option 1 must be ON, “Enter” to save and go to the next menu
 | Clear| Press “Clear” to go back to the main menu
 | 810| To go to Communication Settings
 | 4,4| Press 4 two times to set Ademco Contact ID format for both phones
 | 811| To go to “Partition 1 Account Number”
 | 1234| Enter the desired account number (1234 is an example)
 | Clear| To go back to the main menu
 | 815| To go to “Monitoring station phone number 1”
 | 123456, Enter| Enter the phone number of your choice, and press “Enter” to go back

Enable keyswitch arm/disarm and status output:

LED indication on Keypad Keypad Entry Action Description
  Enter, 0000 To enter Programming mode
  001 To go to Zone 1 definition menu
  26, 1 26 to select Keyswitch, 1 to assign to Partition 1
  Enter, Enter Press “Enter” to confirm, “Enter” to save and go to the next

menu
 | Clear| To go back to main menu
 | 220| To go to Configure PGM1 activation
 | 02| To go to Partition status
 | 12, 01| To select the ARM partition for Partition 1
 | Enter, Clear| “Enter” to save, “Clear” to go back to main menu

Wiring and Programming Uplink Communicators to Paradox SP4000

  221 To go to the DISARM partition for Partition 1
  02 To go to Partition status
  11, 01 To select the DISARM partition for Partition 1
  Enter, Clear To save and go back to main menu
  281 To go to PGM output delays for PGM1
  000 To deactivate the PGM delay timer
  Enter, Clear To save and exit to main menu
  Clear Exit programming mode

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Uplink User Manuals

Related Manuals