Uplink 5530M Hybrid Alarm Control Panel User Guide

June 1, 2024
Uplink

Uplink 5530M Hybrid Alarm Control Panel

Uplink-5530M-Hybrid-Alarm-Control-Panel-Product

Product Information

Specifications:

  • Model: Interlogix Concord 4
  • Compatibility: Works with Uplink’s Cellular Communicators
  • Panel Type: Alarm Panel
  • Reporting Format: Contact ID

Product Usage Instructions

Wiring Uplink’s Cellular Communicators to Interlogix Concord 4:
Follow the wiring diagram provided in the manual to connect the 5530M communicators to the Interlogix Concord 4 panel.

Programming the Interlogix Concord 4 Alarm Panel via the Keypad:

  1. Enter programming mode by pressing 8, followed by the installer code (default code: 4321), then press 00.
  2. To set the Reporting format to Contact ID, enter 01006 and confirm the type by entering 2, #, then ***.
  3. Adjust Open/Close Reports settings by entering 01004, setting the status to ON by entering 2, #, then ***.
  4. Set opening reports status by entering 06100 and confirming the status as ON by entering 2, #, then ***.
  5. Set closing reports status by entering 06101 and confirming the status as ON by entering 2, #, then ***.
  6. To exit System Programming, press BBBB# (press BBBB four times) to save changes and exit.
  7. To set the account number for partition 1, enter 8432103##, set your desired account number, and save by pressing #.
  8. Navigate through the menu to set CS Phone details and confirm with # to save changes.
  9. To program the Keyswitch zone and output, follow the instructions provided in the manual.

FAQ:

  • Q: How do I reset the panel to factory settings?
    A: To reset the Interlogix Concord 4 panel to factory settings, you can perform a default programming reset. Refer to the user manual for specific instructions on how to do this.

  • Q: Can I add additional sensors to the system?
    A: Yes, you can add additional sensors to the Interlogix Concord 4 system. Follow the sensor programming instructions in the manual to learn and configure new sensors.

CAUTION

  • It is advised that an experienced alarm installer programs the panel as further programming may be required to ensure proper performance and use of the full functionality.
  • Do not route any wiring over the circuit board.
  • Full panel testing, and signal confirmation, must be completed by the installer.

NEW FEATURE

For Uplink 5530M Communicators, the panel’s status can be retrieved not only from the status PGM but now also from the Open/Close reports from the dialler. Therefore, wiring the white wire and programming the status PGM of the panel is optional.

MPORTANT NOTE:
The Open/Close reporting must be enabled during the initial pairing procedure.

Wiring Diagram

Wiring the 5530M communicators to Interlogix Concord 4

Uplink-5530M-Hybrid-Alarm-Control-Panel-Fig-1

Programming

Programming the Interlogix Concord 4 Alarm Panel via the Keypad

Enable Contact ID reporting:

Keypad Display

| Keypad Entry|

Action description

---|---|---
Date and Time| 8 4321 00| To enter programming mode.
System Programming| 01006| To display the Reporting format.
Reporting Format “TYPE”| 2, # | “TYPE” is the current programmed type, 2 is for CID, # to confirm, and hit to get to System Programming.
System Programming| 01004| To display Open/Close RPTS.
Open/Close RPTS XX| 2 #| XX is the Current Status, 2 is for ON, and # is to confirm.
Open/Close RPTS ON| | Return to System Programming.
System Programming| 06100| This displays the opening report status.
Opening Reports XX| 2 #| XX is the current status, 2 is for ON, and # is to Confirm.
Opening Reports ON|
| Return to System Programming.
System Programming| 06101| This displays the closing report status.
Closing reports XX| 2 #| XX is for current status, and 2 is for ON.
Closing reports ON| *| Return to System Programming.
Exit System Programming| BBBB#| Press B (4 times down in the menu) to exit System programming.
Date and Time| 8432103##| To set the account number for partition 1.
Account number XXXX| 1234#| Enter your desired account number (1234 is an example), and # to save.
 |
| To get back to an account number.
CS Phone 1| B##| To move through the menu go to CS Phone, ## to select Phone

  1. CS Phone __| 123456#| Enter an actual phone or any number of your choice, # to save.
    CS Phone| **| Exit to the main menu.
    CS Phone| BB| Navigate to End Programming.
    End Programming| #| Press # to confirm.

Program Keyswitch zone and output:

Keypad Display Keypad Entry Action Description
Date and Time 84321 To enter system programming.
System Programming 0014 This enters the keyswitch sensor area.
Key Switch Sensor X#, B X=Zone Number 1-8, # to confirm, press B to get to

keyswitch style.
Key Switch style transition| B **| Press B until the Display shows TRANSITION. Then press a few times to get back to System Programming.
System Programming| 080| Enters the Learn Sensor Menu.
Learn Sensors| #| # opens this menu.
Sensors PTN 1| #| This is the partition area, with 1 as the default. Do not change if 1.
Sensor Group 0| 28#| Choose sensor group 28.

Trip Sensor X

|

| Navigate to chosen zone X (1-8), Short Zone X wire to GND wire. Wait for the panel to beep, then press * until the Learn Sensors

the prompt is displayed.

Learn Sensors| A| To get to edit the sensor area.
Edit Sensors| #| View sensor 1.
S1 P1 G28 NO HW KEY| *| Get back to System Programming.
System Programming| 1121#| Displays output 2 Status.
---|---|---
Output 2 Item 0 “Status| 11#| Output 2 will be armed (ex 11- ARMED).
Output 2 Item 1,| **
| Press * a few times to get back to system programming (11 –

ARMED).

System Programming| 11111| Displays configuration for Output 2.
Configuration XXXXXX| 00903 #| Enter 009=Arm Event, 03=Sustained Response, # to confirm.
Configuration 00903| ***| Press a few times until you get back to System Programming.