Uplink 5530M Paradox Digiplex EVO User Guide

June 1, 2024
Uplink

Uplink 5530M Paradox Digiplex EVO

Uplink-5530M-Paradox-Digiplex-EVO-product

Specifications

  • Product Name: Paradox Digiplex EVO 192
  • Compatible with Uplink’s Cellular Communicators
  • Alarm Panel Programming via Keypad

Product Usage Instructions

Enabling Contact ID Reporting

  1. Enter the Installer code (hold 0), then enter 000000 to access the Programming menu.
  2. Go to the System Options menu: Enter 3035.
  3. Set option 6 to OFF (account number transition for partition number) and press Enter.
  4. Proceed with the required actions as per the manual for sections 3036, 3037, 3061, 3062, 3070, 3071, 3072, and 4031.
  5. To exit programming mode, press Clear.

Enabling Keyswitch Arm/Disarm and Status Output

  1. Enter the Installer code (hold 0), then enter 000000 to access the Programming menu.
  2. Follow the steps outlined in the manual for sections 0101, 0501, 0601, and 3033 to enable keyswitch functionalities.
  3. Proceed with the actions described in section 0910 to configure timers and options.
  4. To exit programming mode, press Clear.

INSTRUCTION

CAUTION

  • It is advised that an experienced alarm installer programs the panel as further programming may be required to ensure proper performance and use of the full functionality.
  • Do not route any wiring over the circuit board.
  • Full panel testing, and signal confirmation, must be completed by the installer.

NEW FEATURE : For Uplink Series Communicators, the status of the panel can be retrieved not only from the status PGM but now also from the Open/Close reports from the dialler. Therefore, wiring the white wire and programming of the status PGM of the panel is optional.

IMPORTANT NOTE : The Open/Close reporting needs to be enabled during the initial pairing procedure.

Wiring

Wiring the 5530M communicator to Paradox Digiplex EVO 192

Uplink-5530M-Paradox-Digiplex-EVO-fig-1

Wiring and Programming Uplink Communicators to Paradox Digiplex EVO 192

Programming the Paradox Digiplex EVO 192 Alarm Panel via the Keypad

Enable Contact ID reporting:

Display Keypad Entry Action Description
Date & Time 0, 000000 Hold 0 to go to Installer code, 000000 to go to

Programming menu.
Section| 3035| To go to System Options menu.
3035 Options| 6 off, Enter| 6 must be OFF (account number transition for partition number), Enter.
3036| 1 off,2 off,| 1 and 2 must be OFF – disable phone line monitoring.
| 3 on,4 on, Enter| 3 and 4 must be ON – (3 is dialer Enabled, 4 Dialer method – tone).
3037| Clear| To go to main menu.
Section| 3061| To go to account number for Partition 1.
3061 Communicator| 1234| Enter desired account number.
3062| Clear| To go to main menu.
Section| 3070| To go to reporting formats.
3070 Communicator| 5555| To select Ademco ContactID for all lines.
3071 Telephone| 123456, Enter| Enter actual or imaginary phone number to report to, Enter to save.
3072 Telephone| Clear| To go to main menu.
Section| 4031| To reset all reporting codes to FF (Default).
Section| Clear| Press Clear to exit programming mode.

Enable keyswitch arm/disarm and status output:

Display Keypad Entry Action Description
Date & Time 0, 000000 Hold 0 to go to Installer code, 000000 to go to

Programming menu.
Section| 0001| To go to Zone 1 programming
Serial/Input| Clear, Enter| Press Clear to remove the 8 digit serial number and the input (only 0s should be visible), then Enter to save and go back to the main menu.
Section| 0101| To go to zone parameters.
0101 Parameters| 01, Enter| 0 – Disable zone type for Zone 1; 1 – Assign Zone 1 to Partition 1.
0102 Parameters| Clear, Clear| To go to main menu.
Section| 0501| To go to keyswitch numbering.
0501 Serial/Input| 8 digit No.

001

| Type again the 8-digit serial number of the panel, 001 to select input 1.
0502 Serial/Input| Clear, Clear| To go to main menu.
Section| 0601| To go to keyswitch parameters.
0601 Parameters| 11, Enter, Clear| 1 to assign keyswitch zone to partition 1, 1 to choose Momentary Keyswitch, Enter to save, and Clear to go back to the main menu.
Section| 3033| To go to System Options 3.

3033 Options

| 7 on, 8 0ff, Enter, Clear, Clear| 7 must be ON (EOL resistor on hardwired zones), 8 must be OFF (disable ATZ zone doubling), Enter to save, Clear, Clear to go back to the main menu.
Section| 0910| To go to PGM Activation programming.
---|---|---
0910 Timers| 064| To select event group “Status 1”.
0911 Timers| 255| To select “Armed” for all zones.
0912 Timers| 000| To disable PGM activation start timer.
0913 Timers| 000| To disable PGM activation end timer.
0914 Timers| 014| To disarm with user code.
0915 Timers| 000| To select Feature Group.
0916 Timers| 000| To disable PGM deactivation start timer.
0917 Timers| 000| To disable PGM deactivation end timer.
0918 Timers| 000| To disable PGM 1 delay
0919 Options| Clear, Clear| To go out of the programming menu.

FAQ

(Frequently Asked Questions)

  • Q: How do I wire Uplink Communicators to Paradox Digiplex EVO 192?
    • A: Refer to the wiring instructions provided in the manual. Ensure proper connections and programming for seamless integration.
  • Q: How can I reset reporting codes to default on Paradox Digiplex EVO 192?
    • A: Follow section 4031 in the manual to reset all reporting codes to FF (Default).
  • Q: What is the process to disarm using a user code?
    • A: Follow the steps outlined in the manual for disarming with a user code under the relevant sections.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)