Uplink SP1738 Alarm Communicators Instruction Manual

June 1, 2024
Uplink

Uplink SP1738 Alarm Communicators

Uplink-SP1738-Alarm-Communicators-product

Specifications

  • Model: Paradox SP1738
  • Compatibility: Uplink 5530M communicator
  • Function: Alarm panel with Contact ID reporting
  • Features: Keypad programming, keyswitch arm/disarm, PGM activation

Product Usage Instructions

Wiring Uplink’s Cellular Communicators to Paradox SP1738:

  1. Connect the Uplink 5530M communicator to the Paradox SP1738 following the wiring instructions in the manual.

Programming the Paradox SP1738 Alarm Panel via the Keypad:

  1. Enable Contact ID reporting:
    • Follow the LED indications on the keypad for programming.
    • Enter the specified codes and commands as indicated.
  2. Enable keyswitch arm/disarm and status output:
    • Follow the LED indications on the keypad for programming.
    • Enter the specified codes and commands as indicated to set upkeyswitch arm/disarm functionality.
  3. Enable PGM activation and deactivation events:
    • Follow the provided instructions to enable PGM activation and deactivation based on ARM and DISARM events.

INSTRUCTION

CAUTION

  • It is advised that an experienced alarm installer programs the panel as further programming may be required to ensure proper performance and use of the full functionality.
  • Do not route any wiring over the circuit board.
  • Full panel testing, and signal confirmation, must be completed by the installer

NEW FEATURE: For 5530M Series Communicators, the status of the panel can be retrieved not only from the status PGM but now also from the Open/Close reports from the dialler. Therefore, wiring the white wire and programming of the status PGM of the panel is optional.

IMPORTANT NOTE: The Open/Close reporting needs to be enabled during the initial pairing procedure

Wiring

Wiring the Uplink 5530M communicator to Paradox SP1738

Uplink-SP1738-Alarm-Communicators-FIG-1

Programming the Paradox SP1738 Alarm Panel via the Keypad

Enable Contact ID reporting

LED indication on Keypad Keypad Entry Action Description
Enter, 0000 To enter programming mode
Enter blinks 131 To go to Reporting Options toggle menu
Enter steady 1 Press 1 until it’s OFF/Dim to enable Always Report Disarming
Enter steady Enter, Clear To go back to the main programming menu
Enter blinks 135 To go to Dialer Options 1 toggle menu

Enter steady

|

1, 2, 3, 4, 5

| Press the respective buttons until 1 and 2 are OFF/Dim (Disable TLM), 3 is ON/Lit (Enable dialer reporting), 4 is ON/Lit (Set dialing to DTMF), 5 is ON/Lit (USA pulse ratio 1:1,5)
Enter steady| Enter, Clear| To go back to the main programming menu
Enter blinks| 136| To go to Dialer Options 2 toggle menu
Enter steady| 3| Press 3 until it’s ON/Lit to enable automatic Contact ID reporting

codes

Enter steady| Enter, Clear| To go back to the main programming menu
Enter blinks| 140| To go to Reporting format
Enter steady| 5, 5| To select Ademco Contact ID reporting for the 1st and 2nd Phone Numbers
Enter blinks| 143| To go to Partition 1 account number
Enter steady| 1234| Enter the desired account number (1234 is just an example)
Enter steady| Enter, Clear| To go back to the main programming menu
Enter blinks| 151| To go to Primary Phone Number
Enter steady| 123456| Enter the desired phone number (123456 is just an example)
Enter steady| Enter, Clear, Clear| To exit programming mode

Enable keyswitch arm/disarm and status output:

LED indication on Keypad Keypad Entry Action Description
Enter, 0000 To enter programming mode
Enter blinks 001 To go to Zone 1 Options menu
Enter steady 7, 1 7 to set Zone 1 type as Keyswitch, 1 to assign Zone 1 to

partition 1
Enter steady| 1, 2| Toggle options to 1-ON/Lit, 2-OFF/Dim to enable momentary Keyswitch and enable regular ARM (Arm/Away)
Enter steady| Enter, Clear| To go back to the main programming menu
Enter blinks| 066| To go to PGM1 delay settings
Enter steady| 0, 0, 0| To set PGM1 delay to 0 seconds
Enter steady| Clear| To go back to the main programming menu
Enter blinks| 120| To go to the PGM activation events menu
Enter steady| 021099| To enable PGM activation when an ARM event is received
---|---|---
Enter steady| Clear| To go back to the main programming menu
Enter blinks| 121| To go to the PGM deactivation events menu
Enter steady| 020999| To enable PGM deactivation when a DISARM event is received
Enter steady| Clear, Clear| To exit programming mode

FAQ

Frequently Asked Questions

  • Q: How do I exit programming mode?
    • A: To exit programming mode, follow the instructions provided in the manual. Typically, you may need to enter specific codes or commands to exit programming mode.
  • Q: How do I enable Contact ID reporting?
    • A: To enable Contact ID reporting, follow the LED indications on the keypad and enter the required codes as specified in the manual.
  • Q: Can I set up keyswitch arm/disarm with this system?
    • A: Yes, you can enable keyswitch arm/disarm functionality by following the programming instructions provided for the Paradox SP1738 alarm panel.

Read User Manual Online (PDF format)