Uplink PC5020 DSC Power 864 User Manual

June 1, 2024
Uplink

Uplink PC5020 DSC Power 864

Product Information

Specifications:

  • Model: DSC Power 864 PC5020
  • Compatibility: Uplink’s 5530M Cellular Communicators
  • Features: Remote upload/download capabilities, Alarm panel programming via keypad

Product Usage Instructions

Programming the Panel:
To program the DSC Power864 PC5020 Alarm Panel via the Keypad:

  1. Ensure the LED indication on the keypad shows “Ready: Steady Green”.
  2. Enter *8 + Installer Code.
  3. Follow the specific keypad entries for different settings as outlined in the manual.
  4. Exit Programming mode by following the instructions provided.

Program Key-switch zone and output:

To program the key-switch zone and output:

  1. Make sure the LED indication on the keypad is as specified in the manual.
  2. Enter the corresponding Keypad Entry for each action described in the manual.
  3. Exit Programming mode after completing the programming.

Program Panel for Upload/Download (UDL):

To program the panel for remote Upload/Download (UDL):

  1. Follow the Display indications on the keypad as outlined in the manual.
  2. Enter the Keypad Entry for each action described to complete the programming.

Frequently Asked Questions (FAQ)

Q: How do I know if the programming was successful?
A: After completing the programming steps, check for specific LED indications on the keypad as mentioned in the manual. A successful programming will be indicated by the corresponding LED status.

DSC Power 864 PC5020
Wiring Uplink ’s 5530M Cellular Communicators and Programming the Panel

CAUTION:

  • It is advised that an experienced alarm installer programs the panel as further programming may be required to ensure proper performance and use of the full functionality.
  • Do not route any wiring over circuit board.
  • Full panel testing, and signal confirmation, must be completed by the installer.

NOTE: For Uplink Communicators, the status of the panel can be retrieved not only from the status PGM but now also from the Open/Close reports from the dialler. Therefore, wiring the white wire and programming of the status PGM of the panel is optional.

IMPORTANT NOTE: The Open/Close reporting needs to be enabled during the initial pairing procedure.

Wiring

Wiring the 5530M communicators to DSC Power864 PC5020

Uplink-PC5020-DSC-Power-864-FIG- \(1\)

Wiring the 5530M with UDM to DSC Power864 PC5020 for remote upload/download

Uplink-PC5020-DSC-Power-864-FIG- \(2\)

Panel via the Keypad

Programming the DSC Power864 PC5020 Alarm Panel via the Keypad

LED indication on

Keypad

| Keypad Entry| Action Description

(Usually those keypads don’t have display – just LEDs)

---|---|---
Ready: Steady Green| *8 + Inst. Code| To enter in Programming mode. (The default Installer code is 5555).
Armed: Steady Red System: Blinking Yellow| 301| To enter section” First phone number”.
Ready: Steady Green System: Blinking Yellow|

1234566#

| Enter actual or non-existing number (any number will do,

“123456” is an example) followed by 6 (F in hex).

Armed: Steady Red System: Blinking Yellow| 310| To enter section “System account code”.
Ready: Steady Green System: Blinking Yellow| 123466| Enter 4-digit account number to receive the events from (“1234” is an example) and close it with 66 in hex.
Armed: Steady Red System: Blinking

Yellow

| 311| To enter section “Partition 1 account code”
Ready: Steady Green System: Blinking Yellow| 1234| Enter 4-digit account number to receive the events from (“1234” is an example).
Armed: Steady Red System: Blinking Yellow| 350| To enter section “Communicator Format Options”
Ready: Steady Green System: Blinking Yellow| 03#| 03 is for Contact ID.
Armed: Steady Red

System: Blinking Yellow

| 351| Alarm/Restore Communicator Call Directions for partition 1
Ready: Steady Green

System: Blinking Yellow

| 1,5#| Toggle 1 to ON to enable Alarm/Restore reports. (if Zone 1 on the keypad is lit – then it’s ON)

Toggle 5 to OFF to disable Alternate Communicator.

Armed: Steady Red System: Blinking

Yellow

| 367| Open/Close Communicator Cell directions for partition 1 (if you have more partitions, repeat this and the next step for 368,369,370 for partition 2,3,4).
Ready: Steady Green System: Blinking Yellow| 1,5#| Toggle 1 to ON to enable Open/Close reports (if Zone 1 on the keypad is lit – then it’s ON).

Toggle 5 to OFF to disable Alternate Communicator.

Armed: Steady Red System: Blinking Yellow| 380| To enter section “First Communicator Options Code”
Ready: Steady Green| 1#| Toggle 1 to ON to enable communications (options 3 and 4 must
System: Blinking Yellow|  | be OFF).
---|---|---
Armed: Steady Red System: Blinking Yellow| 381| To enter section “Second Communicator Options Code”
Ready: Steady Green System: Blinking Yellow| 7#| Toggle 7 to OFF. The system automatically generates all reporting codes transmitted. To manually program the reporting codes in the menu 381, enable option 7 to ON and then set the desired reporting codes in menus 320 to 348.
Armed: Steady Red System: Blinking Yellow| #| Exit Programming mode.

Program Key-switch zone and output:

LED indication on Keypad Keypad Entry Action Description
Ready: Steady Green *8 + Inst. Code To enter in Programming mode. (The

default Installer code is 5555).
Armed: Steady Red System: Blinking Yellow| 202| To section “Partition Zone Assignment”
Ready: Steady Green System: Blinking

Yellow

| 1#| Turn ON (the corresponding LED will be lit) only the zones that you intend to use – the rest must be OFF (LEDs are dim)
Armed: Steady Red System: Blinking Yellow| 001| To configure Zone 1
Ready: Steady Green System: Blinking Yellow| 22#| Enter 22 to program the zone type as “Momentary Keyswitch”
Armed: Steady Red

System: Blinking Yellow

| 013| To section “First System Option Code”
Ready: Steady Green System: Blinking Yellow|

1#

| 1 must be OFF to set the zones to end-of-line wiring configuration
Armed: Steady Red System: Blinking Yellow|

009

| To section “PGM1 and PGM2 Output Programming (Main Panel)”
Ready: Steady Green System: Blinking Yellow| 05#| System Armed Status – output will activate/deactivate upon arm/disarm for selected partitions.
Armed: Steady Red System: Blinking Yellow| #| Exit Programming mode.

Programming the DSC Power864 PC5020 Alarm Panel via the Keypad for remote Upload/Download (UDL)

Program the Panel for Upload/Download (UDL):

Display Keypad Entry Action Description
Ready: Steady Green *8 + Inst. Code To enter in Programming mode. (The

default Installer code is 5555).
Armed: Steady Red

System: Blinking Yellow

| 401| To enter section “First Downloading Option Code”
Ready: Steady Green System: Blinking Yellow| 1,3,6#| 1 and 3 must be disabled. 6 must be enabled.
Armed: Steady Red System: Blinking Yellow| 403| To enter section “Downloading Access Code”
Ready: Steady Green System: Blinking Yellow| 5020| Enter an Access code. (5020 is the default Access Code)
Armed: Steady Red

System: Blinking Yellow

| 404| To enter section “Panel Identification Code”
Ready: Steady Green System: Blinking

Yellow

|

5020

| Enter a Panel Identification Code (5020 is the default Panel ID Code)
Armed: Steady Red System: Blinking Yellow| 405| To enter section “Answering Machine Double-call Timer”
Ready: Steady Green System: Blinking

Yellow

| 001| To disable double call.
Armed: Steady Red System: Blinking Yellow| 406| To enter section “Number of Rings to Answer On”
Ready: Steady Green System: Blinking Yellow| 001| Set the panel to answer on the first ring.
Armed: Steady Red System: Blinking Yellow| #| To Exit Programming Mode.

Keybus integration wiring of Uplink 5530M to DSC Power864 PC5020

Uplink-PC5020-DSC-Power-864-FIG- \(3\)

Keybus integration instructions

  • Connect a wire from DAT1 (MQ Series) or O/OUT (MN Series) terminal of the communicator to the YEL keypad terminal of the alarm panel.
  • Connect a wire from DAT2 (MQ Series) or W/IN (MN Series) terminal of the communicator to the GRN keypad terminal of the alarm panel.
  • Enable the Arming/Disarming feature from the Settings menu of the RControl mobile app.

NOTE 1: If the Arming/Disarming feature is enabled you can use the “Sync with Panel” feature from the Settings menu in the RControl mobile App. This way you will skip disabling and re-enabling the Arming/Disarming.

Switching from Keyswitch to Keybus

  • Wire the device to the panel as described on the respective wiring scheme above.
  • Use the Sync with Panel feature from the Settings menu of the RControl mobile app.

The device will apply the new configuration automatically.

NOTE 2: When switching the wiring of the device, make sure that the device is not powered on.

NOTE 3: When synchronizing or disabling and enabling the Arming/Disarming feature from the mobile application, make sure:

  • the device is powered and connected to cellular network;