HS2016 Wiring Uplink’s Cellular Communicators User Guide

June 1, 2024
Uplink

HS2016 Wiring Uplink’s Cellular Communicators

HS2016-Wiring-Uplink’s-Cellular-Communicators-PRODUCT

Product Information

Specifications:

  • Product Name: DSC NEO Power Series
  • Models: HS2016, HS2032, HS2064, HS2128
  • Compatibility: Uplink’s Cellular Communicators

Frequently Asked Questions

  • Q: How do I reset the panel to default settings?
    • A: To reset the panel to default settings, enter the installer code followed by the appropriate command as outlined in the user manual.
  • Q: Can I add multiple phone numbers for notifications?
    • A: Yes, you can program multiple phone numbers for notifications by following the steps for setting phone numbers in the programming menu.

Information

CAUTION

  • It is advised that an experienced alarm installer programs the panel as further programming may be required to ensure proper performance and use of the full functionality.
  • Do not route any wiring over circuit board.
  • Full panel testing, and signal confirmation, must be completed by the installer.

NEW FEATURE

  • For Uplink Communicators, the status of the panel can be retrieved not only from the status PGM but now also from the Open/Close reports from the dialler.
  • Therefore, wiring the white wire and programming of the status PGM of the panel is optional.

IMPORTANT NOTE: The Open/Close reporting needs to be enabled during the initial pairing procedure.

Wiring

Wiring the 5530M communicators to DSC NEO

HS2016-Wiring-Uplink’s-Cellular-Communicators-FIG-1

Wiring the 5530M with UDM to DSC NEO for remote upload/download

HS2016-Wiring-Uplink’s-Cellular-Communicators-FIG-2

Programming

Programming the DSC NEO Alarm Panel via the Keypad

Enable Contact ID reporting:

Keypad Display Keypad Entry Action description
Select: *85555 To enter in Programming mode
Select: 301 To enter menu” First phone number”
Select: 001 001 To select first phone number
DFFFFF 1234566# Enter actual or non-existing number (any number will do,

123456 is an example) followed by 6 (F in hex).
Select:| 383| Enter Communication Options 4.
Comm. Option 4:| 2#| Toggle 2 to OFF, to set the programmable account code in 310 to 4 digits.
Select:| 310| To enter menu “System account code”.
System Account:| 000| To enter submenu for the whole system (001, 002… for more partitions)
System Account:| 1234| Enter 4-digit account number for CMS identification (1234 is an example)
System Account:| 001| To enter submenu for Partition 1
Part.1 Account:| 1234#| Enter 4-digit account number for CMS identification (1234 is an example)
Select:| 311| To enter menu “Reporting”.
Select:| 001| Go to “Alarm restore” options.
Toggle receiver#1| #| Press to select “Y” (yes) – “Alarm/Restore” events are reported to

telephone number 1

Tamper restore:| 002| To go to “Tamper/Tamper restore”.
Toggle receiver#1| #| Press to select “Y” (yes) – “Tamper/Tamper restore” events are reported to telephone number 1.
Opening/Closing| 003| Go to “Open/Close” events.
---|---|---
 | ##| Press to select “Y” (yes) – “Open/Close” events are reported to

telephone number 1, # to save, # to exit to main menu

Select:| 350| To enter “Communicator Alarm Format” options.
Enter Data:| 001| To select phone number 1
Enter Data:| 03#| 03 is for Contact ID.
Select:| 380| Enter First Communication Options
Comms. Enabled:| 1##| Toggle 1 to ON, 3 and 4 must be off (DTMF touch-tone dialing, DTMF dialing for all attempts).

Program Keyswitch zone and output:

Keypad Display Keypad Entry Action Description
Select: *85555 To enter in Programming mode.
Select: 001 Enter zone definition menu.
Zone definitions * Enter Zone 1 definition.
Zone 1 066 To choose Momentary Keyswitch for Zone 1.
Momentary KSW ## To exit to main menu.
Select: 013 Enter First System Options (to configure Normally Closed Zones).
Toggle 1 * Press * or toggle buttons <> until 1 is OFF (all zones are wired

as normally closed circuits with returns to COM terminal).
Toggle Option 1| ##| Press ## to exit to main menu.
Select:| 009| Enter I/O Programming menu.
PGM 1| 001| To enter PGM 1 subsection.
PGM 1| 115| To program the output to report Armed/Disarmed status.
PGM 1| ##| Press ## to exit to main menu.

Programming the DSC NEO Alarm Panel via the Keypad for remote Upload/Download (UDL)

Program the Panel for Upload/Download (UDL):

Display Keypad Entry Action Description
Date / Time *8 + Inst. Code Enter programming menu. Default installer code

is “5555”.
Enter section| 401| First downloading options toggle menu
Toggle option| 1,3,6#| 1 and 3 should be disabled. 6 should be enabled. Press

to exit.

Enter section| 403| DLS downloading access code.
Enter Hex Data| 915500#| Set this field’s value to its default. Press # to exit.
Enter section| 404| Panel ID code.
Enter Hex Data| 915500#| Set this field’s value to its default. Press # to exit.
Enter section| 405| Double call timer address
Enter Data| 255#| Disable double call.
Enter section| 406| Number of rings address
Enter Data| 001#| Set the panel to answer on the first ring.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals