HS2016 Wiring Uplink’s Cellular Communicators User Guide
- June 1, 2024
- Uplink
Table of Contents
HS2016 Wiring Uplink’s Cellular Communicators
Product Information
Specifications:
- Product Name: DSC NEO Power Series
- Models: HS2016, HS2032, HS2064, HS2128
- Compatibility: Uplink’s Cellular Communicators
Frequently Asked Questions
- Q: How do I reset the panel to default settings?
- A: To reset the panel to default settings, enter the installer code followed by the appropriate command as outlined in the user manual.
- Q: Can I add multiple phone numbers for notifications?
- A: Yes, you can program multiple phone numbers for notifications by following the steps for setting phone numbers in the programming menu.
Information
CAUTION
- It is advised that an experienced alarm installer programs the panel as further programming may be required to ensure proper performance and use of the full functionality.
- Do not route any wiring over circuit board.
- Full panel testing, and signal confirmation, must be completed by the installer.
NEW FEATURE
- For Uplink Communicators, the status of the panel can be retrieved not only from the status PGM but now also from the Open/Close reports from the dialler.
- Therefore, wiring the white wire and programming of the status PGM of the panel is optional.
IMPORTANT NOTE: The Open/Close reporting needs to be enabled during the initial pairing procedure.
Wiring
Wiring the 5530M communicators to DSC NEO
Wiring the 5530M with UDM to DSC NEO for remote upload/download
Programming
Programming the DSC NEO Alarm Panel via the Keypad
Enable Contact ID reporting:
Keypad Display | Keypad Entry | Action description |
---|---|---|
Select: | *85555 | To enter in Programming mode |
Select: | 301 | To enter menu” First phone number” |
Select: 001 | 001 | To select first phone number |
DFFFFF | 1234566# | Enter actual or non-existing number (any number will do, |
123456 is an example) followed by 6 (F in hex).
Select:| 383| Enter Communication Options 4.
Comm. Option 4:| 2#| Toggle 2 to OFF, to set the programmable account code in
310 to 4 digits.
Select:| 310| To enter menu “System account code”.
System Account:| 000| To enter submenu for the whole system (001, 002… for
more partitions)
System Account:| 1234| Enter 4-digit account number for CMS identification
(1234 is an example)
System Account:| 001| To enter submenu for Partition 1
Part.1 Account:| 1234#| Enter 4-digit account number for CMS identification
(1234 is an example)
Select:| 311| To enter menu “Reporting”.
Select:| 001| Go to “Alarm restore” options.
Toggle receiver#1| #| Press to select “Y” (yes) – “Alarm/Restore” events
are reported to
telephone number 1
Tamper restore:| 002| To go to “Tamper/Tamper restore”.
Toggle receiver#1| #| Press to select “Y” (yes) – “Tamper/Tamper restore”
events are reported to telephone number 1.
Opening/Closing| 003| Go to “Open/Close” events.
---|---|---
| ##| Press to select “Y” (yes) – “Open/Close” events are reported to
telephone number 1, # to save, # to exit to main menu
Select:| 350| To enter “Communicator Alarm Format” options.
Enter Data:| 001| To select phone number 1
Enter Data:| 03#| 03 is for Contact ID.
Select:| 380| Enter First Communication Options
Comms. Enabled:| 1##| Toggle 1 to ON, 3 and 4 must be off (DTMF touch-tone
dialing, DTMF dialing for all attempts).
Program Keyswitch zone and output:
Keypad Display | Keypad Entry | Action Description |
---|---|---|
Select: | *85555 | To enter in Programming mode. |
Select: | 001 | Enter zone definition menu. |
Zone definitions | * | Enter Zone 1 definition. |
Zone 1 | 066 | To choose Momentary Keyswitch for Zone 1. |
Momentary KSW | ## | To exit to main menu. |
Select: | 013 | Enter First System Options (to configure Normally Closed Zones). |
Toggle 1 | * | Press * or toggle buttons <> until 1 is OFF (all zones are wired |
as normally closed circuits with returns to COM terminal).
Toggle Option 1| ##| Press ## to exit to main menu.
Select:| 009| Enter I/O Programming menu.
PGM 1| 001| To enter PGM 1 subsection.
PGM 1| 115| To program the output to report Armed/Disarmed status.
PGM 1| ##| Press ## to exit to main menu.
Programming the DSC NEO Alarm Panel via the Keypad for remote Upload/Download (UDL)
Program the Panel for Upload/Download (UDL):
Display | Keypad Entry | Action Description |
---|---|---|
Date / Time | *8 + Inst. Code | Enter programming menu. Default installer code |
is “5555”.
Enter section| 401| First downloading options toggle menu
Toggle option| 1,3,6#| 1 and 3 should be disabled. 6 should be enabled. Press
to exit.
Enter section| 403| DLS downloading access code.
Enter Hex Data| 915500#| Set this field’s value to its default. Press # to
exit.
Enter section| 404| Panel ID code.
Enter Hex Data| 915500#| Set this field’s value to its default. Press # to
exit.
Enter section| 405| Double call timer address
Enter Data| 255#| Disable double call.
Enter section| 406| Number of rings address
Enter Data| 001#| Set the panel to answer on the first ring.