Uplink Vista 20PSIA Cellular Communicators and Programming the Panel Instructions

June 1, 2024
Uplink

Uplink Vista 20PSIA Cellular Communicators and Programming the Panel Instructions

Wiring Uplink’s 5530M Cellular Communicators and Programming the Panel

CAUTION:

  • It is advised that an experienced alarm installer programs the panel as further programming may be required to ensure proper performance and use of the full functionality.
  • Do not route any wiring over circuit board.
  • Full panel testing, and signal confirmation, must be completed by the installer.

NEW FEATURE: For 5530M Communicators, the status of the panel can be retrieved not only from the status PGM but now also from the Open/Close reports from the dealer. Therefore, wiring the white wire and programming of the status PGM of the panel is optional.

Wiring the white wire is necessary only if the Open/Close reporting is disabled.

IMPORTANT NOTE: The Open/Close reporting needs to be enabled during the initial pairing procedure

Wiring the 5530М communicators to Honeywell Vista 20PSIA for events reporting and remote control via Keybus
Wiring Instruction
Wiring the 5530М communicators to Honeywell Vista 20PSIA for events reporting and remote control via Keyswitch
Wiring Instruction
Programming the Honeywell Vista 20PSIA Alarm Panel via the Keypad
Enable Contact ID reporting:

Keypad Display Keypad Entry Action Description
DISARMED 4112800 To enter programming menu
Installer Code *41 To start configuring primary phone number
Pri. Phone 123456* Enter phone number value and press * to save and go back
Sec. Phone *43 To start configuring “Part. 1 Primary Subs. Acct. No.”
Part 1 Sub Id Pri 1234* Enter account number value and press * to save and

go back
Part 1 Sub Id Sec| 47| To enter “Phone system select” menu
Phone Mys| 1
| To select “Tone Dial” and go back
Field?| 48| To enter “Report format” menu
Rep Form Pri/Sec| 7
| To select “Academe Contact ID” for primary phone number
Field?| 65| To go to “Open report code” setup
Open Rpt 1 2 3| 1
| To enable reporting for “Open” event
Field?| 66| To go to “Arm Away/Stay Report Code” menu
Awy/Sty Rp 1 2 3| 1, 1
| To enable reporting for “Away/Stay” events
Field?| 92| To go to “TLM” menu
Telco Monitor| 0
| To disable TLM and save
Field?| *99| To exit programming mode

Program keyswitch zone and status output:

Keypad Display Keypad Entry Action Description
Disarmed 4112800 To enter programming menu
Installer Code *56 To enter “Zone programming”
Set to confirm 1 To confirm you want to enter “Zone programming”
Enter zone No. 03** To start configuring zone #3
Zone Type 77* To set zone type to “Keyswitch”
Partition 1* To assign zone to partition 1
Report code 01* To enable reporting for zone #3
Hardwire Type 0* To enable supervision of the zone (with 2k ohm EOL

resistor)
Resp Time| 1| To set zone response time to 0.35s
Zn ZT P RC HW:RT|
000| To exit zone programming
Press or #| 80| To enter output programming
Output Funct #| 17*| To start configuring function 17
Activated By:| 2
| To select zone type for the activation event
Enter Zn Type| 78| To select Keyswitch red as behavior for the function
Partition| 1
| To assign function to partition 1
Enter Output No.| 17*| To assign function to pin #1 from the 8-pin connector
Output Funct.| 00
99| To exit programming mode

Wiring the 5530M with the Uplink UDM to Honeywell Vista 20PSIA for remote upload\download
Wiring Instruction
Programming the Honeywell Vista 20PSIA Alarm Panel via the Keypad for remote Upload/Download (UDL)

Program the Panel for Upload/Download (UDL):

Display Keypad Entry Action description
Disarmed 4112,8,00 To enter the programming menu
Installer code *95, 1 To set “Number of rings to answer” to 1
Pager 1 Phn No. *99 To save and quit

NOTE:
If the software says that the CSID doesn’t match, *96 while in programming mode initializes CSID and account number (assigns them their default values)

Programming an Alpha Keypad Address

Keypad Display Keypad Entry Action Description
DISARMED 4140,8,00 To enter Programming Mode.
Program Mode #93 To go to “Menu Mode”
Zone Prog. ? 0 … 1 Press 0 until “Device Prog.” is shown. Press 1 to enter.
Device Address 01-30, 00=Quit 21* To enter Address 21
21 Device Type 1* To select Alpha Keypad Console
21 Console Part. 1* To assign the Alpha Keypad Console to Partition 1
21 Sound Option * Press * to exit from Device Address 21 .
Device Address 01-30, 00=Quit 22* To enter Address 22

Note: This Address is optional – if 2nd partition is used
22 Device Type| 1| To select Alpha Keypad Console
22 Console Part.| 2
| To assign the Alpha Keypad Console to Partition 2
22 Sound Option| | Press to exit from Device Address 22 .
Device Address 01-30, 00=Quit| 00| To exit the Device Address menu.
Quit Menu Mode ? 1=YES 0=NO| 1| To exit Menu Mode.
Program Mode|
99| To exit Programming Mode
| | Note: The Vista 50P supports up to 8 Partitions.You will need to repeat the programming steps for Device Addresses 23…28 according to the number of partitions .

Switching from Keyswitch to Keybus

  • Wire the device to the panel as described on the respective wiring scheme.
  • Use the Sync with Panel feature from the Settings menu of the Uplink mobile app.

The device will apply the new configuration automatically.
NOTE 2: When switching the wiring of the device, make sure that the device is not powered on.

NOTE 3 : When synchronizing or disabling and enabling the Arming/Disarming feature from the mobile application, make sure:

  • the device is powered and connected to cellular network;
  • the panel is not in programming menu/mode.

After enabling the Arming/Disarming feature it may take up to 1 minute for the device to apply the new configuration.