Uplink ELK-M1 Cellular Communicators and Programming the Panel User Manual

May 15, 2024
Uplink

Uplink LOGO ELK-M1
Wiring Uplink’s Cellular Communicators
and Programming the Panel 

ELK-M1 Cellular Communicators and Programming the Panel

CAUTION:

  • It is advised that an experienced alarm installer programs the panel as further programming may be required to ensure proper performance and use of the full functionality.
  • Do not route any wiring over circuit board.
  • Full panel testing, and signal confirmation, must be completed by the installer.

NEW FEATURE: For 5530M Communicators, the status of the panel can be retrieved not only from the status PGM but now also from the Open/Close reports from the dialler. Therefore, wiring the white wire and programming of the status PGM of the panel is optional.
IMPORTANT NOTE: The Open/Close reporting needs to be enabled during the initial pairing procedure.

Wiring the 5530M communicators to ELK-M1

Uplink ELK M1 Cellular Communicators and Programming the Panel -
Wiring

Programming the ELK-M1 Alarm Panel via the Keypad

Enable Contact ID reporting:

Display Keypad Entry Action Description
Home screen Menu > Installation programming > Enter code if required To

enter programming mode (default is 172839).
Available menus| Telephone Account Setup|
Telephone number:| 1, Select| To start configuring telephone number 1 options
T1 Option 01: Format| 1 = Contact ID, Next Option| Set reporting format to Contact ID
T1 Option 02: Type| Select, 0 = Always Report, Next Option| Set reporting type to “Always report”
T1 Option 03: Number| Select, 123456, Select option| Set telephone number to 123456
T1 Option 03: Number| Next option, Next option| Press “Next option until you reach “T1 Option 05:”
T1 Option 05: Account Number Area 1| Select, 001234, Next option| Enter the desired account number (001234 is an example). The first 2 digits will be trimmed
T1 Option 06: Account Number Area 2| 13| Press 13 to go to “T1 Option 13:”
T1 Option 13: Report Area, Alarm, Restore & Unbypass| Select, Yes, Next option| Enable reporting for these events. Press “Next option” to save and go to the next option
T1 Option 14: Report Bypasses| Select, Yes, Next option| Enable reporting for these events. Press “Next option” to save and go to the next option
T1 Option 15: Report Zone Troubles| Select, Yes, Next option| Enable reporting for these events. Press “Next option” to save and go to the next option
T1 Option 16: Report User Report Codes| Select, Yes, Next option| Enable reporting for these events. Press “Next option” to save and go to the next option
T1 Option 17: Report Global System Events| Select, Yes, Next option| Enable reporting for these events. Press “Next option” to save and go to the next option, Select phone number Menu to go to the main menu screen
Available menus| Area Reporting Codes| To go to Area Reporting Codes menu
Report Codes Area: 1| Select| To go to Area 1’s reporting codes menu
Area 1 Option 01: Dialer Delay| Select, 000, Select option| Ensure that this option has a value of 000.
Area 1 Option 01: Dialer Delay| | In the range 04 – 19 are the values for different events. Enable the ones required by your installation. When you’re done in this menu, go back to the main programming screen.
Available menus| Next Page, User Report Code| Here are the settings for the users’ Open/Close reports. Set Open and Close settings to something different than 00 in order to enable the reporting for the event.
User 001: USER 1
Open = 00
Close = 00| Select, 01, 01| Just for example we have enabled the Open/Close reports for User 001 in this row. When you enter the values, they are being automatically saved and the system moves the cursor to users selection. Enable the users required by your installation following this procedure.
User 001: USER 1
Open = 01
Close = 01| Menu, Menu, Exit Menu| Press these buttons to exit programming mode.

Program Keyswitch zone and output:

Although the Keyswitch zone can be configured through the keypad, the OUTPUT can be configured only through the panels’ software – therefore in this manual we will configure both the zone and the output through the software.

Uplink ELK M1 Cellular Communicators and Programming the Panel - Program
Keyswitch

From ZONES, select Zone 1, Configure as Key Momentary ARM/DISARM, Type 0 = EOL, Area 1, Press Send to Control

Uplink ELK M1 Cellular Communicators and Programming the Panel - Program
Keyswitch 1

Go to account details > Automation > Rules > Click on New to create New rule

Uplink ELK M1 Cellular Communicators and Programming the Panel - Program
Keyswitch 2Uplink ELK M1 Cellular Communicators and Programming the
Panel - Program Keyswitch 3

Whenever > Security/Alarms > Is Disarmed

Select desired Area

Uplink ELK M1 Cellular Communicators and Programming the Panel - Program
Keyswitch 5Uplink ELK M1 Cellular Communicators and Programming the
Panel - Program Keyswitch 6

Then > Turn Output On/Off

Select Output 003 > Turn off > OK

Uplink ELK M1 Cellular Communicators and Programming the Panel - Program
Keyswitch 8

Select Done to go back to Rules menu

Uplink ELK M1 Cellular Communicators and Programming the Panel - Program
Keyswitch 9

Select New to create new Rule

Uplink ELK M1 Cellular Communicators and Programming the Panel - Program
Keyswitch 10

Whenever > Security/Alarms > Is Armed > Armed to any mode

Select Area 1 and press OK

Uplink ELK M1 Cellular Communicators and Programming the Panel - Program
Keyswitch 12Uplink ELK M1 Cellular Communicators and Programming the
Panel - Program Keyswitch 13

Select Then > Turn Output On/Off

Select Output 003 > Turn On > OK

Uplink ELK M1 Cellular Communicators and Programming the Panel - Program
Keyswitch 15

Press Done to confirm

Uplink ELK M1 Cellular Communicators and Programming the Panel - Program
Keyswitch 16

Press Send to control to activate the rules

Uplink LOGO

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>