Uplink ELK-M1 Cellular Communicators and Programming the Panel User Manual
- May 15, 2024
- Uplink
Table of Contents
ELK-M1
Wiring Uplink’s Cellular Communicators
and Programming the Panel
ELK-M1 Cellular Communicators and Programming the Panel
CAUTION:
- It is advised that an experienced alarm installer programs the panel as further programming may be required to ensure proper performance and use of the full functionality.
- Do not route any wiring over circuit board.
- Full panel testing, and signal confirmation, must be completed by the installer.
NEW FEATURE: For 5530M Communicators, the status of the panel can be
retrieved not only from the status PGM but now also from the Open/Close
reports from the dialler. Therefore, wiring the white wire and programming of
the status PGM of the panel is optional.
IMPORTANT NOTE: The Open/Close reporting needs to be enabled during the
initial pairing procedure.
Wiring the 5530M communicators to ELK-M1
Programming the ELK-M1 Alarm Panel via the Keypad
Enable Contact ID reporting:
Display | Keypad Entry | Action Description |
---|---|---|
Home screen | Menu > Installation programming > Enter code if required | To |
enter programming mode (default is 172839).
Available menus| Telephone Account Setup|
Telephone number:| 1, Select| To start configuring telephone number 1 options
T1 Option 01: Format| 1 = Contact ID, Next Option| Set reporting format to
Contact ID
T1 Option 02: Type| Select, 0 = Always Report, Next Option| Set reporting type
to “Always report”
T1 Option 03: Number| Select, 123456, Select option| Set telephone number to
123456
T1 Option 03: Number| Next option, Next option| Press “Next option until you
reach “T1 Option 05:”
T1 Option 05: Account Number Area 1| Select, 001234, Next option| Enter the
desired account number (001234 is an example). The first 2 digits will be
trimmed
T1 Option 06: Account Number Area 2| 13| Press 13 to go to “T1 Option 13:”
T1 Option 13: Report Area, Alarm, Restore & Unbypass| Select, Yes, Next
option| Enable reporting for these events. Press “Next option” to save and go
to the next option
T1 Option 14: Report Bypasses| Select, Yes, Next option| Enable reporting for
these events. Press “Next option” to save and go to the next option
T1 Option 15: Report Zone Troubles| Select, Yes, Next option| Enable reporting
for these events. Press “Next option” to save and go to the next option
T1 Option 16: Report User Report Codes| Select, Yes, Next option| Enable
reporting for these events. Press “Next option” to save and go to the next
option
T1 Option 17: Report Global System Events| Select, Yes, Next option| Enable
reporting for these events. Press “Next option” to save and go to the next
option, Select phone number Menu to go to the main menu screen
Available menus| Area Reporting Codes| To go to Area Reporting Codes menu
Report Codes Area: 1| Select| To go to Area 1’s reporting codes menu
Area 1 Option 01: Dialer Delay| Select, 000, Select option| Ensure that this
option has a value of 000.
Area 1 Option 01: Dialer Delay| | In the range 04 – 19 are the values for
different events. Enable the ones required by your installation. When you’re
done in this menu, go back to the main programming screen.
Available menus| Next Page, User Report Code| Here are the settings for the
users’ Open/Close reports. Set Open and Close settings to something different
than 00 in order to enable the reporting for the event.
User 001: USER 1
Open = 00
Close = 00| Select, 01, 01| Just for example we have enabled the Open/Close
reports for User 001 in this row. When you enter the values, they are being
automatically saved and the system moves the cursor to users selection. Enable
the users required by your installation following this procedure.
User 001: USER 1
Open = 01
Close = 01| Menu, Menu, Exit Menu| Press these buttons to exit programming
mode.
Program Keyswitch zone and output:
Although the Keyswitch zone can be configured through the keypad, the OUTPUT can be configured only through the panels’ software – therefore in this manual we will configure both the zone and the output through the software.
From ZONES, select Zone 1, Configure as Key Momentary ARM/DISARM, Type 0 = EOL, Area 1, Press Send to Control
Go to account details > Automation > Rules > Click on New to create New rule
Whenever > Security/Alarms > Is Disarmed
Select desired Area
Then > Turn Output On/Off
Select Output 003 > Turn off > OK
Select Done to go back to Rules menu
Select New to create new Rule
Whenever > Security/Alarms > Is Armed > Armed to any mode
Select Area 1 and press OK
Select Then > Turn Output On/Off
Select Output 003 > Turn On > OK
Press Done to confirm
Press Send to control to activate the rules