KSE-LIGHTS FSL-EPS LED Mamba Emergency Power Supply Instruction Manual
- June 1, 2024
- KSE-LIGHTS
Table of Contents
KSE-LIGHTS FSL-EPS LED Mamba Emergency Power Supply
Specifications
- Max Power Output : 1500 Watts
- Input Voltage : AC 100-277V, 7A, 50/60Hz
- Battery : 22.2V, 6000mAh Li-Ion
- Battery Life : 5000 cycles
- IP Rating : IP65
- Output Voltage : DC 175V
- Emergency Light Duration : 2x 60 minutes
- Warranty : 3 years
FAQ
Q: What should I do if the red light flashes continuously?
A: The red light flashing continuously indicates a low battery and the need
for recharging. Connect the device to AC power for charging.
Q: How do I know the battery power levels during emergencies?
A: Press the switch briefly to see red light flashes indicating different
power levels from 0-100%.
CONNECTION
FEATURES
- LED-MAMBA 15M 180W
- 25% LUMENS
- LED-MAMBA 25M 300W
- 20% LUMENS
- LED-MAMBA 50M 600W
- 10% LUMENS
- LED-MAMBA 75M 900W
- 6,5% LUMENS
EMERGENCY POWER SUPPLY POWERS UP IN CASE OF POWER FAILURE
When fully charged, this device offers an immediate emergency response (<1 second) to any AC power outage. The built-in emergency function is activated instantly and continues operation for a duration of 60 minutes before automatically turning off, thanks to the integrated timing system. – If AC power is restored and then experiences a subsequent outage, even if this interruption lasts for merely a second, the emergency function will be triggered again. This will lead to another cycle of operation for 60 minutes. Hence, the device can provide two separate cycles of 60-minute emergency operations under intermittent power conditions.
INSTRUCTION FOR USE
- Charging: The red light indicates a battery charge of less than 90%, and green means more than 90%. The device charges when connected to AC power.
- Discharging: The green light will flash continuously until battery exhaustion.
- Battery Power: Press the switch briefly during emergencies to display power levels via red light flashes:
- 1x flash = 0-20%
- 2x flash = 20-40%
- 3x flash = 40-60%
- 4x flash = 60-80%
- 5x flash = 80-100%.
- Emergency Power: Please always connect the emergency power supply unit to an appropriate power source. Use as a „Battery-Pack“ is not intended.
- Turning Off Emergency Function : Hold the switch for more than 3 seconds.
- Turning On Emergency Function: Disconnect and reconnect AC power. If no load is detected after activation, the output automatically turns off shortly.
- +49 (0)2333 982 47 30