KSE-LIGHTS MCII Series CAP Lamp Instruction Manual
- June 12, 2024
- KSE-LIGHTS
Table of Contents
KS-7620-MCII PERFORMANCE
KS-7630-MCII POWER
MCII Series CAP Lamp
Instruction Manual
MCII Series CAP Lamp
The product complies with the following standards:
EN 60079-0:2018
EN 60079-11 :2012
EN 60079-28 :2015
EN 60079-35-1:2011
IBExU19ATEX1087
Special conditions for use in the Ex atmosphere:
- The cap lamp can be used in an extended ambient temperature of -15 °C to +50 °C
- Damaged equipment must be taken out of service immediately and out of potentially explosive atmosphere.
- The cap lamp may only be charged outside the hazardous area using the appropriate charger.
- The light window must never be completely covered during operation in a potentially hazardous area.
| II 1G Ex ia op is IIC T4 Ga
I M1 Ex ia op is I +H2 Ma
EN 60079-35-1
-15°C <Ta< +50°C (+60°@T2)|
---|---|---
Bold highlighted specifications are only valid for MCII-POWER!
| 70/180/(230) lumens| | IP67| | <9 hours charging
---|---|---|---|---|---
| 80/140/(190) meters| | 165 grams| | precision optics technology
| 30/14/(6) hours| | Li-ion battery| | 5000 Kelvin
| emergency-/work-/(POWER)-Light| | >80% capacity after 500 cycles| | glass-
fibre reinforced plastic
FIRST USE
The cap lamp must be fully charged before first use.
To do this, connect the charger to a suitable power source and push the lamp
into the charger. Make sure that the lamp is fully inserted into the charger.
When the lamp is correctly connected to the charger, an indicator LED in
the lamp will light up red.
The LED on the charging cup indicates the charging status:
Red –> lamp is charging
Green –> lamp is fully charged
The charging current switches off automatically when the battery is fully
charged.
Charging is only permitted in non-hazardous areas! Only use original KSE-
LIGHTS chargers!
After the lamp has been fully charged, the lamp can be switched on using
the on/off switch.
By pressing the switch several times, the individual modes are switched
through as described. After the last mode, the lamp switches off.
The lamp may be used and recharged at any time without negatively affecting
the battery.
The cap lamp has several mounting options:
-to the head with the headband (KS-5525)
-on the helmet with an variable helmet adapter
-at the helmet with helmet spider (KS-5526)
-on the body with the neck strap (KS-5020)
The lamp is resistant to oil, grease, glue, hydrocarbon, turpentine
substitute and various cleaning agents.
Wash the lamp body and the windscreen with lukewarm soapy water. Do not use
acid or abrasive cleaners, especially not on the windscreen.
Do not use a high-pressure hose!
Technical maintenance or repair may only be carried out by KSE-LIGHTS or an
authorised person.
KSE-LIGHTS gives a two-year warranty on the product for material and
manufacturing defects. Excluded from the guarantee are normal wear and tear,
oxidation, changes, improper use, storage and maintenance as well as damage
caused by negligence or use for which the product is not intended.
The warranty on the accumulator is limited to one year. If the serial number
is removed, the warranty is immediately void. Customer service in the event
of a warranty claim, please return the lamp to the dealer with proof of
purchase. It will be repaired or replaced.
Do not open the lamp or charger under any circumstances. Do not use or
recharge the lamp if it is defective. No warranty claims can be made for
consequential damage caused by defective parts. Failure to do so will
invalidate the warranty and the operational safety.
KSE-LIGHTS accepts no liability for direct, indirect and accidental
consequences, as well as any other form of damage due to the use of this
product.
SAFETY INFORMATIONS
- Do not use damaged lamps, chargers or sockets to charge the lamp.
- Never place the switched-on lamp on the light window when working in potential dangerous atmosphere.
- Do not pull the power cord to remove the plug out of the socket.
- Only use original KSE-LIGHTS chargers.
- The use of other chargers may adversely affect the life of the product. KSE-LIGHTS is not responsible for consequential damage, if parts are used which are not authorised by KSELIGHTS.
- Protect the charger and accumulator from damage.
- Never store the products outside the approved temperature range from 0°C to +45°C.
- Never charge the product outside of the approved temperature range from -20°C to +35°C.
- Never use the product at temperature range from -15°C to +50°C.
TROUBLE SHOOTING
When using the cap lamp and charging adapter some malfunctions or operator
failures can appear, here are the solutions:
The cap lamp can not be turned on.
Insert the lamp into the charger and try again. Should the Lamp still show no
response, please contact our product service.
The lamp shows no response to insertion in the charger.
Disconnect the charger from the supply voltage and try again. Should the lamp
still show no reaction, please contact our product service.
Both charge indication LEDs are turned on.
The lamp is fully charged and the charging controller has switched to standby
mode.
Remove the lamp from the charger, switch on shortly and insert again.
Now only one LED should light up.
Repeat the process if both LEDs are still turned on.
After the lamp is fully charged, the green charging indication LED turns
off.
Solution: The lamp is fully charged and the charger has switched to
standby mode. Remove the lamp shortly out of the charger, switch on shortly
and replace back in the charger.
Now an indication LED should light up again.
KSE-LIGHTS GmbH
Thungenfeld 8
58256 Ennepetal Germany
Tel: +49 (0)2333-98247 30
Fax: +49 (0)2333-98247 49
www.kse-lights.com
info@kse-lights.com
MCII-SERIES CHARGER
KS-5330-M/KS-5010-M-DE/KS-2036-M-DE
FIRST USE
- Insert the cap lamp in the charger as shown in the picture. The status LED in the charger lights red. If the status LED turns to green, the lamp is fully charged.
- Please make sure, that there are no objects between the charger and the cap lamp.
- The cap lamp can be charged and recharged anytime.
SAFETY INFORMATIONS
Do not use damaged lamps, chargers or power sockets to charge the lamp. Do not
pull the power cord to remove the AC adapter. Only use original KSE-LIGHTS
chargers. The use of other chargers may have a negative effect on the life of
the product. KSE-IGHTS is not liable for consequential damage if parts are
used which are not approved by KSE-LIGHTS.
Protect the charger and the accumulator from damage.
Never charge the product outside the approved temperature range from 0°C to
+35°C.
The chargers may only be operated with the power supply unit supplied by KSE-
LIGHTS which has the following characteristics.
If a charger should be supplied with voltage by other means, the voltage
source must have one of the following characteristics:
- SELV or PELV system, where the output voltage does not exceed 50 VAC or 120 VDC
- Safety isolating transformer that meets the requirements of IEC 61558-2-6 or a technically equivalent standard.
- Directly with a power supply according to IEC 60950, IEC 61010-1 or a technically equivalent standard.
- Directly from cells or batteries, provided the cell voltage is the same.
Thüngenfeld 8
58256 Ennepetal
Germany
+49 (0)2333 982 47 30
www.shop.kse-lights.com
www.kse-lights.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>