KSE-LIGHTS GmbH KS-7820-IX-DS Dual Spot Cap Lamp Owner’s Manual

October 30, 2023
KSE-LIGHTS GmbH

KSE-LIGHTS GmbH KS-7820-IX-DS Dual Spot Cap Lamp

Product Overview

PRODUCT OVERVIEW

Product Overview

The product complies with the following standards:
EN 60079-0 :2012+A11:2013
EN 60079-11 :2012
EN 60079-28 :2015
EN 60079-35-1 :2012
IBExU 17 ATEX 1134 X

Special conditions for use in the Ex atmosphere:

  1. The cap lamp can be used in an extended ambient temperature of -20 °C to +50 °C
  2. Damaged equipment must be taken out of service immediately and out of potentially explosive atmosphere.
  3. The cap lamp may only be charged outside the hazardous area using the appropriate charger.
  4. The light window must never be completely covered during operation in a potentially hazardous area.

|

II 1G Ex ia op is IIC T4 Ga
I M1 Ex ia op is I +H2 Ma
EN 60079-35-1
-20°C <Ta< +50°C (+60°@T2)

|
---|---|---
| IX-PERFORMANCE / -POWER
40/125/125/(230) lumens
---|---
| IX-PERFORMANCE / -POWER
35/130/50/(180) meters
| Emergency-/distance-/ area-/(POWER)-Light
| IX-DUALSPOT
125/230 lumens
| IX-DUALSPOT
130/250 meters
| Distance-/ POWER-distance
| <11 hours charging
| IP68
| 40/12/12/(6) hours
| >80% capacity after 800 cycles
| 5000 Kelvin
| 175 grams

FIRST USE

The cap lamp must be fully charged before first use. To do this, connect the charger to a suitable power source and push the lamp into the charger. Make sure that the lamp is fully inserted into the charger.

Now a red charging status LED in the lamp will light up constantly. This diode signals an active charging process. As soon as the charging process is completed, the red LED goes out and a green LED lights up constantly.
The lamp is now fully charged. Please read the safety regulations regarding charging.
After the lamp has been fully charged, the lamp can be switched on using the on/off switch.

By pressing the switch several times, the individual modes are switched through as described. After the last mode, the lamp switches off.

The lamp has a display that indicates the current battery level. The display is always activated for 15 seconds after the lamp is switched off. The battery status is divided into 3 levels: green= > 70% orange= >30 to 70% red= <30 To determine the battery status as accurately as possible, leave the light on for at least 10 seconds.

The lamp may be used and recharged at any time without negatively affecting the battery.

If the lamp is connected to the charger when  it is switched on, the emergency light function is activated. When the charging process starts, the light goes out. If the mains voltage is now disconnected, the light switches on automatically and thus ensures an illuminated environment during the emergency situation.

The lamp is resistant to oil, grease, glue, hydrocarbon, turpentine substitute and various cleaning agents.
Wash the lamp body and the windscreen with lukewarm soapy water. Do not use acid or abrasive cleaners, especially not on the windscreen.

Do not use a high-pressure hose! Technical maintenance or repair may only be carried out by KSE-LIGHTS or anauthorised person.

KSE-LIGHTS gives a two-year warranty on the product for material and manufacturing defects. Excluded from the guarantee are normal wear and tear, oxidation, changes, improper use, storage and maintenance as well as damage caused by negligence or use for which the product is not intended.

The warranty on the accumulator is limited to one year. If the serial number is removed, the warranty is immediately void. Customer service in the event of a warranty claim, please return the lamp to the dealer with proof of purchase. It will be repaired or replaced.

Do not open the lamp or charger under any circumstances. Do not use or recharge the lamp if it is defective. No warranty claims can be made for consequential damage caused by defective parts. Failure to do so will invalidate the warranty and the operational safety.

KSE-LIGHTS accepts no liability for direct, indirect and accidental consequences, as well as any other form of damage due to the use of this product.

SAFETY INFORMATIONS

Do not use damaged lamps, chargers or sockets to charge the lamp.

Never place the switched-on lamp on the light window when working in potential dangerous atmosphere.

Do not pull the power cord to remove the plug out of the socket.

Only use original KSE-LIGHTS chargers.

The use of other chargers may adversely affect the life of the product. KSE- LIGHTS is not responsible for consequential damage, if parts are used which are not authorised by KSE-LIGHTS.

Protect the charger and accumulator from damage.

Never store the products outside the approved temperature range from 0°C to +45°C.

Never charge the product outside of the approved temperature range from 0°C to +35°C. Never use the product at temperature range from -20°C to +50°C.

TROUBLE SHOOTING

When using the cap lamp and charging adapter some malfunctions or operator failures can appear, here are the solutions:

The cap lamp can not be turned on.
Insert the lamp into the charger  and try again. Should the Lamp still show no response, please contact our product service.

The lamp shows no response to insertion in the charger. Disconnect the charger from the supply voltage and try again. Should the lamp still show no reaction, please contact our product service.

Product Overview

FIRST USE

  1. Insert the cap lamp in the charger as shown in the picture. The status LED inside the lamp is red. When the status LED turns to green, the lamp is fully charged.
  2. Please make sure, that there are no objects between the charger and the cap lamp.
  3. The cap lamp can be charged and recharged anytime.

| KS-5400-IX

AC 110 – 230V , 50/60Hz incl. EU/UK/AU/US

|
---|---|---
| KS-5410-IX

DC 12-24V / for vehicle

|

SAFETY INFORMATIONS

Do not use damaged lamps, chargers or power sockets to charge the lamp. Do not pull the power cord to remove the AC adapter. Only use original KSE-LIGHTS chargers. The use of other chargers may have a negative effect on the life of the product. KSE-LIGHTS is not liable for consequential damage if parts are used which are not approved by KSE-LIGHTS.
Protect the charger and the accumulator from damage.
Never charge the product outside the approved temperature range from 0°C to +35°C. The chargers may only be operated with the power supply unit supplied by KSE-LIGHTS which has the following characteristics.
If a charger should be supplied with voltage by other means, the voltage source must have one of the following characteristics:

  • SELV or PELV system, where the output voltage does not exceed 50 VAC or 120 VDC
  • Safety isolating transformer that meets the requirements of IEC 61558-2-6 or a technically equivalent standard.
  • Directly with a power supply according to IEC 60950, IEC 61010-1 or a technically equivalent standard.
  • Directly from cells or batteries, provided the cell voltage is the same.

Declaration of Conformity
according to directive 2014/34/EU (ATEX directive)
according to directive 2014/53/EU (RED directive)

Manufacturer: KSE-LIGHTS GmbH

Address :  Thüngenfeld 8 58256 Ennepetal

Product: LED cap lamp

Types: KS-7830-IX, KS-7840-IX (lamps)
KS-5400-IX, KS-5410-IX, KS-2036-IX (charging devices)

Description: LED cap lamp with a compact plastic housing and attachment for work safety helmets. The lamp includes a light source and a rechargeable accumulator. It is not intended to be opened.

EU type examination certificate: IBExU17ATEX1134 X

Marking: I M1 Ex ia op is I + H2 Ma EN 60079-35-1
II 1G Ex ia op is IIC T4 Ga
0158

Issuer of EU type examination certificate:
IBExU Institut für Sicherheitstechnik GmbH
Fuchsmühlenweg 7
09599 Freiberg

Applied standards for ATEX directive:
EN 60079-0:2012+A11:2013  EN 60079-28:2015
EN 60079-11:2012  EN 60079-35-1:2011

Applied standards for RED directive:
EN IEC 60598-1:2021+A11:2022   EN 60598:2-4:2018
EN 62493:2015
EN IEC 62311:2020

ETSI EN 301 489-1 V2.2.3 (2019-11) ETSI EN 301 489-3 V2.3.2 (2023-01)
EN IEC 55015:2019+A11:2020 EN IEC 61000-3-2:2019/A1:2021
EN 61000-3-3:2013+A1:2019+A2:2021 EN 61547:2009
ETSI EN 303 417 V1.1.1 (2017-09

KSE-LIGHTS GmbH
Ennepetal, 26.05.2023

Signature:

Nikolai Seel (General management)

This declaration certifies compliance with the indicated directives but implies no assurance of properties.
The safety of the product information should be observed. This statement turns off automatically whenever changes are made to the product, that have not been matched with the company KSE-LIGHTS GmbH

KSE-LIGHTS GmbH
Thungenfeld 8
58256 Ennepetal
Germany

Tel: +49 (0)2333-98247 30
Fax: +49 (0)2333-98247 49
www.kse-1ights.com
[email protected]

Bankverbindung:
Sparkasse an Ennepe und Ruhr
IBAN: DE62 4545 1060 0000 0927 67
Swift/Bl(: WELADED1 ENE

Geschaftsfuhrer: Detlev Seel / Nikolai Seel
WEEE-Reg.-Nr.: DE 270 590 52
Registergericht Hagen HRB 7367
USt-ld Nr.: DE 814 691 073

KSE-LIGHTS Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals