COOPER Lumiere Lanterra 1002 LED Accent and Flood Light Instruction Manual

June 3, 2024
Cooper

COOPER logo

Instruction Manual
IL506001EN
Installation Instructions – Lumiere Wrx (Remote driver housing –
Round Wall or Round Square)

Lumiere Lanterra 1002 LED Accent and Flood Light

WARNING
Make Certain Power is OFF before starting installation or attempting any maintenance.
WARNING
Risk of Fire/Electric Shock. If not qualified, consult an electrician.
WARNING
Risk of Electric Shock – Disconnect power at fuse or circuit breaker before installing or servicing.
WARNING
Risk of Personal Injury – The fixture may become damaged and/or unstable if not installed properly.

  • Do not mount the luminaire within 6” of a combustible surface.
  • Do not handle the luminaire by the glass. Do not touch LEDs.

WARNING
Risk of Burn – Disconnect power and allow the fixture to cool before servicing.

Note:
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation, or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for the user’s purpose, please contact your nearest representative.
Note:
This lighting fixture has been shipped complete with one of several mounting options. Please follow the installation instructions specific to the catalog part that you ordered.
Note:
Care must be taken not to set lighting fixtures down on optical lenses or lift the fixture in the lens area.
Note:
Specifications and dimensions are subject to change without notice.

IMPORTANT: Read carefully before installing the fixture. Retain for future reference.
GENERAL: Upon receipt of the fixture, thoroughly inspect for any freight damage which should be brought to the attention of the delivery carrier. Compare the catalog description listed on the packing slip with the fixture label on the housing to assure you have received the correct material.
SAFETY: This fixture must be wired in accordance with the National Electrical Code and applicable local codes and ordinances. Proper grounding is required to ensure personal safety. Carefully observe the grounding procedure under the installation section.
APPLICATIONS: This lighting fixture is designed for outdoor lighting services, and should not be used in areas of limited ventilation or inside high ambient temperature enclosures. It must be stored in a dry location prior to installation. Do not expose the lighting fixture to rain, dust, or other environmental conditions prior to installation and insertion of photo control or shorting cap (if so equipped). Do not install the fixture near combustible materials or locate next to airflow-blocking surfaces within 6 inches. The best results will be obtained if installed and maintained according to the following recommendations.COOPER Lumiere Lanterra 1002 LED Accent and Flood
Light

Note: *Constructions built before Jan 2022 may have gray wire for 0-10 dimming control present. In these cases, the installer will label the gray building wire as a 0-10 dimming wire and connect it to our product’s pink 0-10V dimming control wire. Reference NFPA70 (2020 NEC), section 410.69.

INSTALLATION

ACCENTS

  1. Unpack and ensure all included parts are present.
  2. Remove the bottom end cap (with two conduit entries) and gasket (B) by unscrewing 4x #8-32 screws (A).
  3.  Mounting plate (C) will slide out from tracks in extruded driver housing (H).
  4. Place mounting plate (C) on the surface to outline attachment location holes (D). The properly secure mounting plate on the mounting surface.
  5. Attach conduit with power supply wires (K) to bottom end cap (B).
  6. Connect the Input power supply wires (K) coming out of the driver housing (H) to power supply wires (K), following the wiring table.
  7. Remove the Top end cap (with one conduit entry) and gasket (G) by unscrewing 4x #8-32 screws (F).
  8. Attach conduit and fixture lead wires (J) to the top end cap (G). Recommended using min 18ga wires and 1000VAC min voltage rating. Max remote distance is 25ft for light level L3 and 60ft for light levels L1, L2, LC1, and LC2.
  9. (example catalog number: 9004-W1-RW-LED4080-S-BKL3-UNV-WRR).
  10. Connect the DC Output wires (J) coming out of the driver housing (H) to fixture lead wires (J), following the wiring table.
  11. Push wires inside the driver housing (H). Return the top end cap and gaskets (G) to the top of the driver housing (H). Ensure proper sealing of driver housing (H).
  12. Slide driver housing (H) back onto mounting tracks (E). Push wires inside the driver housing (H). Return the bottom end cap and gasket (B) to the bottom of the driver housing.
    Ensure proper sealing of driver housing (H).COOPER Lumiere Lanterra 1002 LED
Accent and Flood Light ACCENTS Figure 1. FIXTURE ASSEMBLY 1000-A1-WRS VERSION****

COOPER Lumiere Lanterra 1002 LED Accent and Flood Light
Figure9 Figure 2. REMOTE DRIVER ENCLOSURE| COOPER Lumiere Lanterra 1002 LED Accent and Flood Light
Figure10Figure 3. REMOTE DRIVER ENCLOSURE
---|---
COOPER Lumiere Lanterra 1002 LED Accent and Flood Light Figure
5Figure 4. 1000-A1-WRR VERSION| COOPER Lumiere Lanterra 1002 LED Accent and Flood Light Figure
5Figure 5. 1000-S1-WRR VERSION
---|---
COOPER Lumiere Lanterra 1002 LED Accent and Flood Light Figure
6 Figure 6. 1000-S1-WRR VERSION| COOPER Lumiere Lanterra 1002 LED Accent and Flood Light
Figure7Figure 7. MOUNTING PLATE (C)
13. Route fixture lead wires (J) from remote driver housing (H) to junction box. 14. Unscrew 4x mounting hardware (L) from the junction box cover plate (M). 15. Route fixture lead wires (J) and ground wire out of a center hole in junction box cover plate (M), Attach junction box cover plate (M) to existing junction box with proper hardware (not included). 16. Connect fixture lead wires (J) from remote driver housing (H) to fixture assembly (N) following the wire table. Ensure the ground wire is attached to the junction box. 17. Attach mount plate and gasket (P) to junction box cover plate with 4x mounting hardware (L). Ensure adequate gasket compression to provide a proper seal from the environment. 18. Using a 3/32” Allen Wrench, slightly loosen the knuckle base set screw (R) for rotational adjustment. Using a 9/64” Allen Wrench, slightly loosen the knuckle joint screw  (S) for angle adjustment. Once properly positioned, ensure both screws are secured.

CYLINDERS

  1. Unpack and ensure all included parts are present.
  2. Remove the bottom end cap (with two conduit entries) and gasket (B) by unscrewing 4x #8-32 screws (A).
  3. Mounting plate (C) will slide out from tracks in extruded driver housing (H).
  4. Place mounting plate (C) on the surface to outline attachment location holes (D). The properly secure mounting plate on the mounting surface.
  5. Attach conduit with power supply wires (K) to bottom end cap (B).
  6. Connect the Input power supply wires (K) coming out of the driver housing (H) to power supply wires (K), following the wiring table.
  7. Remove the Top end cap (with one conduit entry) and gasket (G) by unscrewing 4x #8-32 screws (F).
  8. Attach conduit and fixture lead wires (J) to the top end cap (G). Recommended using min 18ga wires and 1000VAC min voltage rating. Max remote distance is 25ft for light level L3 and 60ft for light levels L1, L2, LC1, and LC2.
  9. (example catalog number: 9004-W1-RW-LED4080-S-BKL3-UNV-WRR).
  10. Connect the DC Output wires (J) coming out of the driver housing (H) to fixture lead wires (J), following the wiring table.
  11. Push wires inside the driver housing (H). Return the top-end cap and gaskets (G) to the top of the driver housing (H). Ensure proper sealing of driver housing (H).
  12. Slide driver housing (H) back onto mounting tracks (E). Push wires inside the driver housing (H). Return the bottom end cap and gasket (B) to the bottom of the driver housing.
    Ensure proper sealing of driver housing (H).COOPER Lumiere Lanterra 1002 LED
Accent and Flood Light Figure8

Figure 8. FIXTURE ASSEMBLY 9000-W1-WRS VERSION

COOPER Lumiere Lanterra 1002 LED Accent and Flood Light
ACCENTS1 Figure 9. REMOTE DRIVER ENCLOSURE| COOPER Lumiere Lanterra 1002 LED Accent and Flood Light
ACCENTS2Figure 10. REMOTE DRIVER ENCLOSURE
---|---

CYLINDERS

  1. Route fixture lead wires (J) from remote driver housing (H) to junction box.
  2. Unscrew 2x mounting hardware (L) from the junction box cover plate (M).
  3. Route fixture lead wires (J) and ground wire out of a center hole in junction box cover plate (M), Attach junction box cover plate (M) to existing junction box with proper hardware (not included).
  4. Connect fixture lead wires (J) from remote driver housing (H) to fixture assembly (N) following the wire table. Ensure the ground wire is attached to the junction box.
  5. Attach mount plate and gasket (P) to junction box cover plate with 2x mounting hardware (L). Ensure adequate gasket compression to provide a proper seal from the environment.COOPER Lumiere Lanterra 1002 LED Accent and Flood Light Figure11

Figure 11. FIXTURE ASSEMBLY 9000-W1-WRS VERSION

CYLINDERS (ADDITIONAL VIEWS)

COOPER Lumiere Lanterra 1002 LED Accent and Flood Light
CYLINDERS

Warranties and Limitations of Liability
Please refer to www.cooperlighting.com for our terms and conditions.

Cooper Lighting Solutions
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
© 2022 Cooper Lighting Solutions
All Rights Reserved
Printed in the USA
Imprimé aux États-Unis
Impreso en Los EE. UU.
Publication No. IL506001EN
March 14, 2022
Cooper Lighting Solutions is a
registered trademark.
All trademarks are property
of their respective owners.
Product availability, specifications,
and compliances are subject to
change without notice.COOPER logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>