Specifications

  • Product Name: PR8R12RING Interactive Menu
  • Product Type: 8-inch LED retrofit shallow lensed downlight
  • Control Compatibility: WaveLinx LITE, WaveLinx PRO
  • Frame Lumens: 10 = 1,000 lumens, 15 = 1,500 lumens, 20 = 2,000 lumens, 30 = 3,000 lumens, 40 = 4,000 lumens (all nominal)
  • LED Module Options: PR8M12 provides 1000, 1500, or 2000 lumens depending on frame type, PR8M34 provides 3000 or 4000 lumens depending on frame type
  • Flange Finish Options: MW (Matte White), MB (Matte Black), MMS (Matte Metallic Silver)

Product Features

  • Interactive menu for easy navigation
  • LED retrofit downlight for energy-efficient lighting
  • Compatible with WaveLinx LITE and WaveLinx PRO control systems
  • Available in various frame lumens and LED module options for customizable lighting solutions
  • Different flange finish options to suit different aesthetics

Dimensional and Mounting Details

  • Overall Diameter: 14 inches [364mm]
  • Cutout Diameter: 12-1/2 inches [318mm]
  • Depth: 2-11/16 inches [69mm]

Product Usage Instructions

  1. Ensure power is switched off before installation.
  2. Choose the appropriate frame lumens and LED module combination based on your lighting needs.
  3. Mount the downlight according to the provided dimensional details.
  4. If using additional accessories like the retrofit collar kit, follow the provided installation instructions.
  5. Connect the downlight to the compatible control system for enhanced functionality.

FAQ

  • Q: Can I use the LED module with any frame type?
    A: No, the LED module options are specific to certain frame types to ensure proper compatibility and performance.

  • Q: What is the purpose of the retrofit collar kit?
    A: The retrofit collar kit is designed to facilitate the retrofit of 12-inch ceiling cutout apertures with an oversized trim  ring for a seamless installation.

Project| | Catalog #| | Type|
---|---|---|---|---|---
Prepared by| | Notes| | Date|

COOPER-Lighting-Solutions-PR8R10-LED-Retrofit-Shallow-Lensed-Downlight-
\(1\)

HALO Commercial
PR8R10/PR8R15/PR8R20/PR8R30/PR8R40 | PR8M12/PR8M34 | PR8R12RING

8-inch LED retrofit shallow lensed downlight

Typical Applications
Office • Healthcare • Hospitality • Institutional • Mixed-Use/Retail

COOPER-Lighting-Solutions-PR8R10-LED-Retrofit-Shallow-Lensed-Downlight-
\(2\)

Interactive Menu

  • Order Information page 2
  • Product Specifications page 3
  • Photometric Data page 4
  • Energy & Performance Data page 6
  • Connected Systems page 9
  • Product Warranty

Top Product Features

  • Retrofit downlight; 1,000 to 4,000 lumens
  • Retrofits 7”, 8”, 9” open frames and 10” and 12” with accessory trim ring kits
  • Medium and Wide interchangeable lens distributions; Wall wash accessory kit option
  • Selectable color temperatures: 3000K, 3500K and 4000K CCT; 80 CRI
  • Universal voltage 120V-277V; Standard 0-10V driver dims to 1%

Dimensional and Mounting Details

COOPER-Lighting-Solutions-PR8R10-LED-Retrofit-Shallow-Lensed-Downlight-
\(3\) Order Information
FRAME SAMPLE NUMBER: PR8R40D010
A complete luminaire consists of a frame and LED module, order separately.

Frame Lumens Driver Factory Installed Options
Frame Lumens Driver Factory Installed Options
--- --- --- ---

PR8R = 8” aperture LED downlight frame PR8RCP = 8” aperture LED downlight frame, CCEA listed for City of Chicago plenum requirements|

  • 10 = 1,000 lumens (nominal)
  • 15 = 1,500 lumens (nominal)
  • 20 = 2,000 lumens (nominal)
  • 30 = 3,000 lumens (nominal)
  • 40 = 4,000 lumens (nominal)

| D010 = 120-277V 50/60Hz, 0-10V 100% to 1% dimming| REM7 = 7W emergency battery pack with remote test switch and charge indicator light. For use with D010 only. (1) (2)

REM14 = 14W emergency battery pack with remote test switch and charge indicator light. For use with D010 only. (1) (2)

BOD7ST = 7.5 watt Bodine self-test diagnostic emergency module with remote test / indicator light, use with D010 only (1)

| | |
| | | WTA = Factory installed WaveLinx PRO Sensor Kit (1) (3)
| | | WTK = Factory installed WaveLinx LITE Sensor Kit (1) (4)
| | | WPN = WaveLinx PRO Wireless Node without sensor (5)
| | | WLN = WaveLinx LITE Wireless Node without Sensor (6)
| | DLV = Distributed Low Voltage dimming driver 1%-100%,| REMV7 = 7W low voltage emergency module with remote test switch.
| | 1000-4000 lumens only. For use with DLVP system only, refer to DLVP specifications for details| For use with DLV only. (1) (2)

REMV14 = 14W low voltage emergency module with remote test

| | | switch. For use with DLV only. (1) (2)
Notes| Notes| Notes| Notes
| | |

  1. Not available with CP version.
  2. UL qualifiedfor US only (not Canada).
  3. WTA = WaveLinx PRO tile mount sensor kit for daylight dimming, PIR motion  sensing, and optional RLTS  – Real Time Location Services, use with D010 only. (Refer   to WaveLinx PRO system specifications.)
  4. WTK = WaveLinx LITE tile mount sensor kit for daylight dimming, PIR motion sensing, use with D010 only. (Refer to WaveLinx LITE system specifications.)
  5. WPN = WaveLinx PRO wireless node provides  luminaire-level  control  with  scene and zone configuration without an integrated sensor; Connects wirelessly with daylight dimming sensor and PIR motion sensor if desired. Use with 0-10V driver only. (Refer to WaveLinx PRO system specifications.)
  6. WLN = WaveLinx LITE wireless node provides luminaire-level control  with  scene and zone configuration without an integrated sensor; Connects wirelessly with daylight dimming sensor and PIR motion sensor  if  desired.  Use  with  0-10V  driver only. Not compatible with 347V or Chicago plenum. (Refer to WaveLinx LITE system specifications.)

MODULE SAMPLE NUMBER: PR8M34MDMW
A complete luminaire consists of a frame and LED module, order separately.

LED Module Shielding Flange Finish Accessories

PR8M12 = Downlight LED module for PR8 series, provides 1000, 1500 or 2000 lumens (nominal) depending on connected frame type

PR8M34 = Downlight LED module for PR8 series, provides 3000 or 4000 lumens (nominal) depending on connected

frame type

| MD = Medium distribution plastic lens

WD = Wide distribution plastic lens

| MW = Matte White

MB = Matte Black

MMS = Matte Metallic Silver

| PR8WW = Field Installed wall wash optic for PR8M12 and PR834 modules

PR8MD = Replacement 8” medium distribution lens for PR8M12 and PR8M34 modules PR8WD = Replacement 8” wide distribution lens for PR8M12 and PR8M34 modules PR8TC = Specular clear trim insert for PR8M12 and PR8M34 modules

PR8TH = Semi-specular clear trim insert for PR8M12 and PR8M34 modules

ABR10P = Oversize trim ring for max 10” ceiling opening – 11.3” flange

WTA = Field installed WaveLinx PRO Sensor Kit (1) (3)

WTK = Field installed WaveLinx LITE Sensor Kit (1) (4)

12-inch Retrofit Accessory Ki t

PR8R12RING = Retrofit collar / Oversize trim ring kit for retrofit of 12” nominal ceiling cutout apertures with integral 15.375” O.D. oversized matte white trim ring. Retrofit collar includes dual pairs of retrofit springs installed in the collar for retention to existing fixture/ceiling pan. PR8RxxD010 installs through the collar.

Notes| Notes| Notes| Notes
| | |

  • (1) Not available with CP version.
  • (3) WTA = WaveLinx PRO tile mount sensor kit for daylight dimming, PIR motion sensing, and optional RLTS – Real Time Location Services, use with D010 only. (Refer to WaveLinx PRO system specifications.)
  • (4) WTK = WaveLinx LITE tile mount sensor kit for daylight dimming, PIR motion sensing, use with D010 only. (Refer to WaveLinx LITE system specifications.)

Product Specifications

Housing Frame

  • Die-formed galvanized steel retrofit frame arm with integrated junction box
  • One-piece construction attaches to LED module for installation in an existing commercial downlight from below the finished ceiling
  • UL listed with Cooper commercial frames and classified with other compatible frames
  • Retrofit frame arm attaches to the LED module with knurled thumb screws

LED Module

  • Integrated self-flanged reflector with finish options of matte white, matte metallic silver, and black
  • LED array uses a plurality of mid-power surface-mount LED packages dwelivering high flux and excellent efficiency
  • Patented SeleCCTable™ technology allows the color temperature to be selected in the field, providing flexibility and reduces ordering complexity
  • Selectable color temperatures in 3000K, 3500K and 4000K correlated color temperature (CCT)
  • Lumen options include 1,000, 1,500, 2,000, 3,000 and 4,000 lumens (nominal)
  • Available in 80 color rendering index (CRI)
  • Color accuracy within 3 SDCM provides color consistency and uniformity (refer to chromaticity information for details)
  • Integral connector allows for quick connection to the housing flex
  • Passive thermal management achieves 50,000 hours at 70% lumen maintenance (L70) in insulated ceilings (IC) and non-IC applications

LED Module – Optics

  • Interchangeable polymer lens pre-installed in LED module
  • Available in medium and wide distribution patterns and can be interchanged without tools
  • Optional field-installed wall wash kit offers 360° rotation, allowing the housing to be installed in any orientation

LED Module – Retention

  • Module retained with two mouse trap springs holding the flange tightly to the finished ceiling surface
  • Mouse trap springs ship with PR8R for field installation on the PR8M module (replacing torsion springs with mouse trap springs)
  • Listed for eight #12 AWG (four in, four out) 90˚C conductors and feed-thru branch wiring
  • Three 1/2” and two 3/4” trade size pry-outs available
  • Three 4-port push wire nuts for mains voltage with 1- port for fixture connection

Driver

  • Driver is preinstalled and prewired to the junction box on the retrofit frame arm
  • Field-replaceable constant current driver provides low noise operation
  • Universal 120-277VAC 50/60Hz input standard
  • Continuous, 1% to 100% dimming with 0-10V analog control
  • Optional low-voltage DC driver for use with Distributed Low Voltage Power (DLVP) system
  • Distributed Low Voltage Power (DLVP) system combines power, lighting and controls with ease of installation (refer to DLVP Design Guide at www.cooperlighting.com for details)

Emergency Option

  • Provides 90 minutes of standby lighting, meeting most life safety codes for egress lighting
  • Available with 7- or 14-watt emergency battery pack with remote charge indicator and test switch
  • Available Self-Test (self-diagnostic) with remote charge indicator and test switch

Connected Lighting System
Two WaveLinx connected solutions to choose from. Refer to WaveLinx system specifications and application guides for details.

WaveLinx PRO Tilemount Sensor Kit
WaveLinx PRO WTA tilemount sensor kit offers daylight dimming, PIR motion sensing, scene and zone configuration, automatic commissioning; and optional RLTS – Real Time Location Services available.
WaveLinx PRO Wireless Node
WaveLinx PRO WPN wireless node provides luminaire-level control with scene and zone configuration without an integrated sensor; Connects wirelessly with daylight dimming sensor and PIR motion sensor if desired. Use with 0-10V driver only. Note: Not compatible with 347V or Chicago plenum.
WaveLinx LITE Tilemount Sensor Kit
WaveLinx LITE WTK tilemount sensor kit offers daylight dimming and PIR motion sensing, scene and grouping configuration.
WaveLinx LITE Wireless Node
WaveLinx LITE WLN wireless node provides luminaire level control with scene and zone configuration without an integrated sensor; Connects wirelessly with daylight dimming sensor and PIR motion sensor if desired. Use with 0-10V driver only. Note: Not compatible with 347V or Chicago plenum.

WaveLinx Tilemount Sensor Kits Application

  • The WTA and WTK tilemount sensor kits include a control module mounted on the luminaire junction box via 1/2” knock-out, and a tilemount sensor on 54-inch whip; for ceiling installation by direct-mount spring clips or via mounting bracket in octagon ceiling boxes.
  • The WTA and WTK tilemount sensor kits may be ordered as factory installed on the luminaire, or ordered separately as a field installed accessory kit.
    Note : WaveLinx PRO devices are only compatible with the WaveLinx PRO system.
    Note : WaveLinx LITE devices are only compatible with the WaveLinx LITE system.

Junction Box

  • Galvanized steel junction box
  • 20 in3 internal volume excluding voltage barrier
  • 25 in3 internal total volume
  • Voltage barrier for 0-10V dimming wires (occupies one 1/2” pry-out space)

Compliance

  • cULus Certified to UL 1598 / C22.2 No. 250.0, suitable for damp locations and wet locations in covered ceilings only
  • IP55 rated
  • Non-Insulated ceiling (Non-IC) rated for 3,000 and 4,000 lumen models (insulation must be kept 3” from top and sides)
  • Insulated ceiling (IC) rated for 1,000, 1,500 and 2,000 lumen models and suitable for direct contact with air permeable insulation* (IC models are also suitable for Non-IC installations)
  • Airtight per ASTM-E283-04
  • Optional City of Chicago environmental air (CCEA) marking for Chicago Plenum applications
  • EMI/RFI emissions FCC CFR Title 47 Part 15 Class A at 120/277V
  • Contains no mercury or lead and RoHS compliant Photometric testing completed in accordance of IES LM-79-08 and TM-30-15
  • Lumen maintenance projection in accordance of IES LM-80-08 and TM-21-11
  • May be used to comply with State of California Title 24 non-residential code as a dimmable LED luminaire
  • Suitable for use in clothes closets when installed in accordance with the NEC 410.16 spacing requirements
  • ENERGY STAR® certified, reference certified light fixtures database
  • Not for use in direct contact with spray foam insulation, consult NEMA LSD57-2013

Warranty

Five year limited warranty, consult website for details. www.cooperlighting.com/legal

Photometric Data

MEDIUM DISTRIBUTION PHOTOMETRY

  • PR8R40D010 – PR8M34MDMW – 3500K Spacing Criteria = 1.04
  • Lumens per Watt = 114 Lm/W
  • Test No. P210425
  • Test Model: PR8R40D010-PR8M34MDMW-3500K

COOPER-Lighting-Solutions-PR8R10-LED-Retrofit-Shallow-Lensed-Downlight-
\(4\)

Zonal Lumen Summary

Zone| Lumens| % Fixture
0-30| 1909| 38.5
0-40| 2911| 58.7
0-60| 4540| 91.5
0-90| 4961| 100
Candela Distribution

Degrees Vertical| Candela
0*| 2753
5| 2737
10| 2642
20| 2281
30| 1838
40| 1388
50| 1011
60| 553
70| 168
80| 13
90| 0
Luminance

(Average Candela/M 2 )
Degree| Avg. 0° Luminance
45| 51175
55| 43697
65| 24049
75| 8495
85| 0

Beam diameter is to 50% of maximum footcandles, rounded to the nearest half- foot. Footcandle values are initial, apply appropriate light loss factors where necessary.
*CBCP

WIDE DISTRIBUTION PHOTOMETRY
PR8R40D010 – PR8M34WDMW – 3500K Spacing Criteria = 1.37
Lumens per Watt = 113.4 Lm/W
Test No. P210455
Test Model: PR8R40D010-PR8M34WDMW-3500K

Zonal Lumen Summary

Zone| Lumens| % Fixture
0-30| 1617| 32.8
0-40| 2681| 54.3
0-60| 4340| 88
0-90| 4933| 100
Candela Distribution

Degrees Vertical| Candela
0*| 1941
5| 1966
10| 1967
20| 1952
30| 1813
40| 1544
50| 991
60| 539
70| 262
80| 72
90| 0
Luminance

(Average Candela/M 2 )
Degree| Avg. 0° Luminance
45| 56914
55| 39531
65| 27449
75| 18527
85| 13480

Beam diameter is to 50% of maximum footcandles, rounded to the nearest half- foot. Footcandle values are initial, apply appropriate light loss factors where necessary.
*CBCP

WALL WASH PHOTOMETRY
PR8R40D010 – PR8M34WW – 3500K Spacing Criteria = 0.99
Lumens per Watt = 95.9 Lm/W
Test No. P210485
Test Model: PR8R40D010-PR8M34WW-3500K

COOPER-Lighting-Solutions-PR8R10-LED-Retrofit-Shallow-Lensed-
Downlight-03COOPER-
Lighting-Solutions-PR8R10-LED-Retrofit-Shallow-Lensed-Downlight-
\(7\)

Energy & Performance Data

Lumens 1000 Series
Input Voltage 120-277VAC 120V
Input Current (A) 0.09
Input Power (W) 10.5

THD: ≤ 20%
PF:≥ 0.90
T Ambient -30 – +40°C
Sound Rating ≤ 22dba
Lumens| 1500 Series
---|---
Input Voltage 120-277VAC| 120V| 277V
Input Current (A)| 0.125| 0.06
Input Power (W)| 15| 15.5
THD: ≤ 20%
PF:≥ 0.90
T Ambient -30 – +40°C
Sound Rating ≤ 22dba
Lumens| 2000 Series
---|---
Input Voltage 120-277VAC| 120V| 277V
Input Current (A)| 0.18| 0.08
Input Power (W)| 22| 22.5
THD: ≤ 20%
PF:≥ 0.90
T Ambient -30 – +40°C
Sound Rating ≤ 22dba
Lumens| 3000 Series
---|---
Input Voltage 120-277VAC| 120V| 277V
Input Current (A)| 0.24| 0.10
Input Power (W)| 28.5| 28.5
THD: ≤ 20%
PF:≥ 0.90
T Ambient -30 – +40°C
Sound Rating ≤ 22dba
Lumens| 4000 Series
---|---
Input Voltage 120-277VAC| 120V| 277V
Input Current (A)| 0.36| 0.16
Input Power (W)| 43.5| 43
THD: ≤ 20%
PF:≥ 0.90
T Ambient -30 – +40°C
Sound Rating ≤ 22dba

Notes
Emergency Battery packs are rated for a minimum starting temperature of 0°C.

Lumen Tables

1000 Lumen, 10.5W 3000K 3500K 4000K
Lumens LPW Lumens LPW
Medium Distribution Lens, Matte White Trim 1176 112 1326
Medium Distribution Lens, Matte Black Trim 1072 102 1209
Medium Distribution Lens, Matte Metallic Silver Trim 1137 108 1282
1203 115
Wide Distribution Lens, Matte White Trim 1172 112 1322
Wide Distribution Lens, Matte Black Trim 1063 101 1198
Wide Distribution Lens, Matte Metallic Silver Trim 1126 107 1270
1192 114
Wall Wash Optic, Matte White Trim 996 95 1130
1500 Lumen, 15W 3000K 3500K 4000K
--- --- --- ---
Lumens LPW Lumens LPW
Medium Distribution Lens, Matte White Trim 1597 106 1800
Medium Distribution Lens, Matte Black Trim 1455 97 1641
Medium Distribution Lens, Matte Metallic Silver Trim 1543 103 1740
1633 109
Wide Distribution Lens, Matte White Trim 1591 106 1794
Wide Distribution Lens, Matte Black Trim 1443 96 1627
Wide Distribution Lens, Matte Metallic Silver Trim 1529 102 1724
1618 108
Wall Wash Optic, Matte White Trim 1349 90 1534
2000 Lumen, 22W 3000K 3500K 4000K
--- --- --- ---
Lumens LPW Lumens LPW
Medium Distribution Lens, Matte White Trim 2186 99 2465
Medium Distribution Lens, Matte Black Trim 1992 91 2246
Medium Distribution Lens, Matte Metallic Silver Trim 2113 96 2382
2236 102
Wide Distribution Lens, Matte White Trim 2179 99 2456
Wide Distribution Lens, Matte Black Trim 1975 90 2227
Wide Distribution Lens, Matte Metallic Silver Trim 2093 95 2360

101
Wall Wash Optic, Matte White Trim| 1847| 84| 2100| 95| 1971| 90
3000 Lumen, 28.5W| 3000K| 3500K| 4000K
---|---|---|---
Lumens| LPW| Lumens| LPW| Lumens| LPW
Medium Distribution Lens, Matte White Trim| 3217| 113| 3630| 127| 3376| 118
Medium Distribution Lens, Matte Black Trim| 2917| 102| 3292| 116| 3062| 107
Medium Distribution Lens, Matte Metallic Silver Trim| 3092| 108| 3488| 122| 3244| 114
Wide Distribution Lens, Matte White Trim| 3200| 112| 3610| 127| 3358| 118
Wide Distribution Lens, Matte Black Trim| 2901| 102| 3274| 115| 3045| 107
Wide Distribution Lens, Matte Metallic Silver Trim| 3075| 108| 3469| 122| 3227| 113
Wall Wash Optic, Matte White Trim| 2702| 95| 3053| 107| 2840| 100
4000 Lumen, 43.5W| 3000K| 3500K| 4000K
---|---|---|---
Lumens| LPW| Lumens| LPW| Lumens| LPW
Medium Distribution Lens, Matte White Trim| 4397| 101| 4961| 114| 4614| 106
Medium Distribution Lens, Matte Black Trim| 3987| 92| 4498| 103| 4184| 96
Medium Distribution Lens, Matte Metallic Silver Trim| 4225| 97| 4767| 110| 4433| 102
Wide Distribution Lens, Matte White Trim| 4372| 101| 4933| 113| 4588| 105
Wide Distribution Lens, Matte Black Trim| 3965| 91| 4473| 103| 4161| 96
Wide Distribution Lens, Matte Metallic Silver Trim| 4201| 97| 4740| 109| 4409| 101
Wall Wash Optic, Matte White Trim| 3698| 85| 4172| 96| 3880| 89

Dimensional Details

PR8R12RING DIMENSIONS

COOPER-Lighting-Solutions-PR8R10-LED-Retrofit-Shallow-Lensed-Downlight-
\(8\)

Housing Compatibility

**Manufacturer| ****Series| Nom. Size| Housing Aperture| ****Housing Catalog #| Ceiling Aperture| ****Retrofit Kit| Oversize Trim Ring
---|---|---|---|---|---|---|---
Cooper Lighting Solutions| PDS| 7| 7.625| PD7| **












7.7″ MIN

9″ MAX

| ****












PR8R

| ****












None

Cooper Lighting Solutions| Portfolio| 7| 7.700| C7, CLW7, HD7, MD7
Juno| Indy Performance Series (Elate)| 8| 7.813| A8, C8, M8
Juno| | 8| 7.813| CH8 and CV8
Juno| | 8| 8.188| MX8 and TC908
Lithonia| Gotham| 8| 8.438| AF-8 and LG-8
Lithonia| Gotham| 8| 8.563| GRSF
Philips| Omega| 8| 8.563| OM8
Lithonia| Commercial| 8| 8.563| LF8, LP8
Cooper Lighting Solutions| Portfolio| 8| 8.730| C8
Philips| Lightolier Calculite| 8| 8.750| S8
Philips| Capri| 8| 8.875| CM8
Cooper Lighting Solutions| PDS| 8| 8.875| PD8
Juno| | 9| 8.938| C9H
Juno| Indy Performance Series (Elate)| 9| 9.000| C9 and M9
Philips| Capri| 10| 9.625| CM10| ****





9″ MIN

10.3″ MAX

| ****





PR8R

| ****





ABR10

(accessory)

Philips| Omega| 10| 9.813| OM10 and S10
Juno| Indy Performance Series (Elate)| 10| 9.875| M10
Cooper Lighting Solutions| Portfolio| 9| 10.000| C9
Lithonia| Gotham| 10| 10.125| GRSF
Lithonia| Gotham| 10| 10.125| AF, LGF, LGH, AH, A
Lithonia| Gotham| 10| 10.250| GRSH

Connected Solutions

WaveLinx LITE devices only compatible with the WaveLinx LITE system.

WaveLinx LITE – WTK Tilemount Sensor

  • Intuitive Android™ or Apple® iOS® app for basic system code compliant set up and configuration via Bluetooth
  • Up to 28 unique areas per project site (WaveLinx LITE Bluetooth network)
  • Up to 50 devices for an area, any one of 16 control zones, up to 6 occupancy sets, and custom lighting scenes
  • Automatic occupancy or vacancy, sensor sensitivity, daylight dimming, etc. configurable through the app
  • Refer to the WaveLinx system specifications for details

COOPER-Lighting-Solutions-PR8R10-LED-Retrofit-Shallow-Lensed-Downlight-
\(10\)

WaveLinx LITE WTK Tilemount Wiring Diagram

COOPER-Lighting-Solutions-PR8R10-LED-Retrofit-Shallow-Lensed-Downlight-
\(11\)

WaveLinx LITE Bluetooth Enabled System

COOPER-Lighting-Solutions-PR8R10-LED-Retrofit-Shallow-Lensed-Downlight-
\(12\)

WaveLinx PRO – WTA Tilemount Sensor
WaveLinx PRO devices only compatible with the WaveLinx PRO system.

  • WaveLinx PRO tilemount functionality configures zones and customizes settings from one secure mobile app
  • Automatic code commissioning that meets the strictest codes
  • Fixtures and sensors integrate with Wireless Area Controller, Wall Stations, and Control Devices
  • Stand-Alone Offices or Entire Building Network Installations

COOPER-Lighting-Solutions-PR8R10-LED-Retrofit-Shallow-Lensed-Downlight-
\(14\)

WaveLinx WTA Tilemount Wiring DiagramCOOPER-Lighting-Solutions-PR8R10
-LED-Retrofit-Shallow-Lensed-Downlight- \(15\)

WaveLinx mobile app settings COOPER-Lighting-Solutions-PR8R10-LED-
Retrofit-Shallow-Lensed-Downlight- \(16\)

WaveLinx CORE Building Management Integration

COOPER-Light

Connected Solutions

WaveLinx LITE Wireless Node – WLN
WaveLinx LITE devices only compatible with the WaveLinx LITE system.

  • Intuitive Android™ or Apple® iOS® app for basic system code compliant set up and configuration via Bluetooth
  • Up to 28 unique areas per project site (WaveLinx LITE Bluetooth network)
  • Up to 50 devices for an area, any one of 16 control zones, up to 6 occupancy sets, and custom lighting scenes
  • Refer to the WaveLinx system specifications for details

WaveLinx mobile app settingsCOOPER-Lighting-Solutions-PR8R10-LED-
Retrofit-Shallow-Lensed-Downlight- \(19\)

WaveLinx LITE Wireless Node (WLN) Wiring DiagramCOOPER-Lighting-
Solutions-PR8R10-LED-Retrofit-Shallow-Lensed-Downlight-
\(20\)

WaveLinx LITE Bluetooth Enabled System COOPER-Lighting-Solutions-PR8R10
-LED-Retrofit-Shallow-Lensed-Downlight- \(21\)

WaveLinx PRO Wireless Node – WPN
WaveLinx PRO devices only compatible with the WaveLinx PRO system.

  • WaveLinx Wireless functionality configures zones and customizes settings from one secure mobile app
  • Automatic code commissioning that meets the strictest codes
  • Fixtures and sensors integrate with WaveLinx Area Controller, Wall Stations, and Control Devices
  • Stand-Alone Offices or Entire Building Network Installations

COOPER-Lighting-Solutions-PR8R10-LED-Retrofit-Shallow-Lensed-Downlight-
\(23\)

WaveLinx mobile app settingsCOOPER-Lighting-Solutions-PR8R10-LED-
Retrofit-Shallow-Lensed-Downlight- \(24\)

WaveLinx PRO Wireless Node (WPN) Wiring Diagram

COOPER-Lighting-Solutions-PR8R10-LED-Retrofit-Shallow-Lensed-Downlight-
\(25\)

WaveLinx CORE Building Management Integration

COOPER-Lighting-Solutions-PR8R10-LED-Retrofit-Shallow-Lensed-Downlight-
\(26\)

Cooper Lighting Solutions
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com

© 2023 Cooper Lighting Solutions
All Rights Reserved.
Specifications and dimensions
subject to change without notice.
PS517020EN page 10
April 3, 2024 9:02 PM

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

COOPER Lighting Solutions User Manuals

Related Manuals