Specifications:

  • Suitable for wet locations
  • Suitable for mounting within 1.2m (4ft) of ground
  • Requires a remote transformer
  • For use with maximum 25A, 12V-15V power unit only
  • Fixture voltage range : 10V min – 13V max

Product Usage Instructions

Installation :
Mounting to Junction Box:

  1. Push fixture wires through the threaded hole of the junction box cover and screw stem in. Use lock nut to firmly hold the fixture.
  2. Connect fixture wires to the transformer wires (polarity not critical).
  3. Attach the fixture and cover with cover gasket securely to the junction box.

To Adjust Fixture Aiming:

Mounting to Ground Spike:

  1. Push fixture wires through the hole in the spike and thread the fixture stem onto the spike.
  2. Connect fixture wires to the transformer wires (polarity not critical).
  3. Plunge the spike into the ground at the desired landscape location.

Note: Lumiere ground spikes and other accessories need to be ordered separately. Loosen set (B) with Allen wrench, aim fixture. Tighten the screw.

Lamp Requirements:

  • For Cambria 201: 12V, MR 11, 35 Watt max Bi-Pin halogen lamp.
  • For Cambria 201-DC: 12V, MR 11, 35 Watt max D.C. Bayonet Base halogen lamp.
  • For Cambria 203: 12V, MR 16, 50 Watt max Bi-Pin halogen lamp.
  • For LED version: 12V, 8 or 12 Watt max Bi-Pin LED module.
  • Check package and fixture labeling for proper lamp type and wattage.

FAQ:

  1. Q: Can I replace the lamp with a higher wattage than specified?
    A: No, do not exceed the maximum wattage listed on the fixture label. Using a higher wattage lamp can cause a safety hazard.

  2. Q: What should I do if the fixture gets hot during operation?
    A: Turn off the fixture and allow it to cool before handling or replacing the lamp. Do not touch the hot components with bare hands.

  3. Q: Is it necessary to use UL listed waterproof wire connectors for electrical connections?
    A: It is recommended to use UL listed waterproof wire connectors to ensure safe electrical connections and prevent damage to the fixture.

Installation Instructions – Cambria 201, 201-DC, 203

WARNING
IMPORTANT SAFETY INFORMATION – READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS.

  • Product must be installed in accordance with all National Electrical Code, Canadian Electrical Code, and all Local and Provincial Codes.
  • Follow product label information and instructions before installing fixture. Retain installation instructions for future reference.
  • Wiring and installation to be performed by a qualified electrician only. Turn OFF power before initial installation, servicing and maintenance.
  • To reduce the risk of FIRE OR INJURY TO PERSONS: Lighted lamp is HOT! Turn OFF fixture and allow to cool before replacing lamp. Do not touch hot lens, guard, or enclosure. Keep away from combustible materials. Do not touch the lamp at any time. Use a clean, dry, soft cloth to handle the lamp. Oil from skin may damage the lamp.
  • Replace lamp only with correct wattage and type of lamp marked on label. DO NOT exceed the maximum wattage listed on the fixture label.
  • Keep fixture lens area clear and free from debris as this may cause an unsafe condition.
  • The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition and void product warranty.
  • All gaskets, O-rings and sealing surfaces must be kept clean during installation and service; failure to do this may cause an unsafe condition and void product warranty.
  • Use UL listed waterproof wire connectors when making electrical connections (recommended).
  • Replace removable parts after servicing.

IMPORTANT LISTINGS AND CERTIFICATIONS SPECIFIC TO FIXTURE

  • SUITABLE FOR WET LOCATIONS.
  • SUITABLE FOR MOUNTING WITHIN 1.2M (4FT) OF GROUND.
  • ATTENTION: A remote transformer is required. For use with maximum 25A, 12V-15V power unit only. Fixture voltage is 10V min – 13V max.

HARDWARE REQUIRED FOR INSTALLATION (PROVIDED BY OTHERS)

  • 9/64” Allen Wrench
  • 5/64” Allen Wrench
  • Wire connectors (recommend silicone filled outdoor rated wire connectors)

INSTALLATION

Mounting to Junction Box

  1. Push fixture wires through the threaded hole of the junction box cover and screw stem in. Use lock nut to firmly hold the fixture.
  2. Connect fixture wires to the transformer wires (polarity not critical).
  3. Attach the fixture and cover with cover gasket securely to the junction box.

Mounting to Ground Spike

  1. Push fixture wires through the hole in the spike and thread the fixture stem onto the spike.
  2. Connect fixture wires to the transformer wires (polarity not critical).
  3. Plunge the spike into the ground at the desired landscape location.
    Note
    Lumiere ground spikes and other accessories need to be ordered separately.

To Adjust Fixture Aiming
Loosen set (B) with allen wrench (provided by others), aim fixture. Tighten the screw. (Figure 1.)COOPER-Lighting-Solutions-ADL141228-LED-Low-Voltage-
Cambria-Accent-Flood- \(1\)

Figure 1.

Lamp Requirements

  • For 201: 12V, MR 11, 35 Watt max Bi-Pin halogen lamp.
  • For 201-DC: 12V, MR 11, 35 Watt max D.C. Bayonet Base halogen lamp.
  • For 203 (Shown) : 12V, MR 16, 50 Watt max Bi-Pin halogen lamp. (Figure 2.)
  • For 203 (LED): 12V, 8 or 12 Watt max Bi-Pin LED module.
  • Check package and fixture labeling for proper lamp type and wattage.COOPER-Lighting-Solutions-ADL141228-LED-Low-Voltage-Cambria-Accent-Flood- \(2\)

Figure 2.

To Relamp

  • Spray socket with WD40. Do not use a lamp of higher wattage than recommended.
  • MR11 and MR16 Bi-Pin: Unscrew the hood, pull lamp out. Push new lamp in.
  • MR11 and MR16 D.C. Bayonet base : Push lamp into the socket. Turn, pull the lamp out. Push new lamp into socket by aligning pins on side of lamp with the slots in the sides of the socket.
  • LED : Unscrew the hood. Remove the two 4-40 screws and pull out the module. Install new module making sure the LED pins are aligned with socket. Install two 4-40 screws making sure heat sink on  the LED makes full contact on the fixture base.

CAUTION

  • Do not over-tighten screws when replacing LED module.
  • When replacing hood, make sure to not over tighten. Doing so will compromise O-Ring seal and will void warranty. Make sure hood is seated snug on O-Ring

Note: Lumiere ground spikes and other accessories need to be ordered separately.

Warranties and Limitations of Liability

Please refer to www.cooperlighting.com for our terms and conditions.

  • Cooper Lighting Solutions 18001 East Colfax Avenue Aurora, CO 80011
  • Cooper Lighting Solutions is a registered trademark.
    • All trademarks are property of their respective owners. Cooper Lighting Solutions

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

COOPER Lighting Solutions User Manuals

Related Manuals