Pico Technology DO348-2 PicoDiagnostics Optical Balancing Kit User Guide

June 15, 2024
pico Technology

Pico-logo

Pico Technology DO348-2 PicoDiagnostics Optical Balancing Kit

Pico-Technology-DO348-2-PicoDiagnostics-Optical-Balancing-Kit-
product

Product Information

Specifications

  • Product Name : Pico Diagnostics Picnic+ Optical Balancing Kit
  • Manufacturer : Pico Technology
  • Compatibility : Designed for use with a Pico Scope oscilloscope
  • Standard Compliance: EN 61010-1:2010+A1:2019 (Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use), EN 61010-2-030: 2010 (Requirements for Testing and Measuring Circuits)

Introduction
Thank you for purchasing the Pico Diagnostics Optical Balancing Kit. This kit, when used with a Pico Scope oscilloscope, allows for the rebalancing of vehicle props hafts to eliminate vibrations.

Safety Warnings
The Pico Diagnostics Optical Balancing Kit has been designed and tested to meet safety standards. Please review the following safety precautions to avoid injury and equipment damage

  • WARNING: Strong magnetic fields may affect or disable the operation of pacemakers, ICDs, and other implanted medical devices. Do not use this product if you or people nearby are fitted with such devices.
  • WARNING: The magnet can attract metallic objects or other magnets from large distances, causing trapping injuries. Handle with care.
  • WARNING: Do not operate the Pico Diagnostics kit while driving the vehicle. Take a passenger with you to operate the software.
  • CAUTION: Route cables away from moving parts when using the props haft balancing accessories to avoid entrapment.
  • CAUTION: Route cables away from hot engine components to avoid melting
  • CAUTION: Do not apply voltage to the Pico BNC+ connector on the Optical sensor as it is an output only.
  • CAUTION: Strong magnetic fields can damage sensitive electronic devices and magnetic material.
  • CAUTION: Dispose of this product properly according to WEEE regulations. Do not dispose of as unsorted municipal waste.

Connection
To connect the Pico Diagnostics Optical Balancing Kit to your scope

  1. Connect the supplied cable with Pico BNC+ connector to the power and data ports on your scope.

Magnetic Base Mounting Instructions

  1. Verify that the mounting surface is flat and free from contamination.
  2. Position the unit in the desired location.
  3. Turn the locking switch to secure the unit.
  4. Adjust the position of the sensor as required using the adjustment knob.

Environment and Storage
For storage and operating conditions, please refer to the accessory section in the scope safety guide. Remember to turn off the magnetic base when in storage.

Troubleshooting

Problem Check Action
Optical sensor not working Check connection Refer to edge detection check

below
Is LED on?| Yes| Does green edge detection indicator LED work when tested?
Is LED on?| No| Check connection

FAQ

  • Q: Can I use the Pico Diagnostics Optical Balancing Kit with any oscilloscope?
    A: No, the kit is specifically designed for use with a Pico Scope oscilloscope.

  • Q: Are there any specific safety precautions I should be aware of?
    A: Yes, please refer to the safety warnings section in the user manual for detailed safety precautions.

  • Q: How should I dispose of this product at the end of its life?
    A: Either return the product to the manufacturer or ensure WEEE compliant collection and treatment. Do not dispose of as unsorted municipal waste.

Introduction

Thank you for buying the Pico Diagnostics Optical Balancing Kit. Used with a Pico Scope oscilloscope, it allows the rebalancing of vehicle props hafts to eliminate vibrations.

Safety warnings

  • The product has been designed and tested in accordance with the harmonized standard publication EN 61010-1:2010+A1:2019 (Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use) and EN 61010-2-030: 2010 (Requirements for Testing and Measuring Circuits). The product left the factory in a safe condition. For more information, please refer to your products UKCA and EU declaration of conformity.
  • Please review the following safety precautions to avoid injury and equipment damage.
  • WARNING identifies conditions or practices that could result in injury or death.

CAUTION identifies conditions or practices that could result in damage to the product or the equipment to which it is connected.

  • WARNING

  • Strong magnetic fi elds may affect or disable the operation of pacemakers, ICDs and other implanted medical devices. To avoid injury or death do not use this product if you or other people nearby are fi tted with such devices.
    The magnet can attract metallic objects or other magnets from large distances, causing trapping injuries unless care is taken when handling.

  • WARNING
    To avoid an accident do not operate the Pico Diagnostics kit while driving the vehicle. Take a passenger with you to operate the software.

  • CAUTION

  • Appearance on the product indicates a need to read these safety and operation instructions.

  • To avoid entrapment take care to route any cables away from moving parts when using the propshaft balancing accessories.

  • To avoid melting of cables take care to route them away from hot engine components when using this product.

  • Do not apply a voltage to the PicoBNC+ connector on the Optical sensor. The PicoBNC+ connector is an output only.

  • Strong magnetic fi elds can damage sensitive electronic devices and magnetic material such as credit cards or portable storage media.

  • Your help and efforts are required to protect and keep our environment clean. Therefore either return this product at the end of life to the manufacturer or ensure WEEE compliant collection and treatment yourself. Do not dispose of as unsorted municipal waste.

Connection
Power and data connection to scope is made by supplied cable ended with PicoBNC+ connector.

Magnetic base mounting instructions

  1. Verify that the mounting surface is flat and free from contamination.
  2. Position the unit in the desired location.
  3. Turn the locking switch to secure the unit.
  4. Adjust the position of sensor as required, using the adjustment knob.
  5. Environment and storage

For storage and operating conditions, refer to the accessory section in the scope safety guide.
Turn off the magnetic base when in storage.

Troubleshooting

Problem Check Action
Optical sensor not working Is LED on? Yes

below
No| Check connection
Does green edge detection indicator
LED work when tested?| Yes| Check lead
No| Check sensor

Specifications (excluding scope)

Optical sensor type LED
Optical sensor operating distance <1 m
Optical sensor speed range 1 to 250,000 rpm
Waterproof NO, for indoor or outdoor use in dry location only

Conformance

Environmental approvals Rohs, WEEE
Safety approvals Designed to- EN 61010-1:2010+A1:2019, Laser EN

60825-1:2014-3
EMC approvals| Tested to meet EN 61326-1:2013 and FCC Part 15 Subpart B

Pack contents

Part Number Description
PA100 Optical kit carry case
TA187 Magnetic base for optical sensor
TA188 Directional tape measure for propshaft balancing
TA497 PicoBNC+ optical sensor
TA240 Reflective tape for optical sensor

United Kingdom headquarters North America regional office Germany regional office and

Pico Technology

  • James House
  • Colmworth Business Park St. Neots
  • Cambridgeshire
  • PE19 8YP
  • United Kingdom
  • Tel : +44 (0) 1480 396395
  • Email : support@picotech.com

Pico Technology

  • 320 N Glenwood Blvd
  • Tyler
  • TX 75702
  • United States
  • Tel : +1 800 591 2796
  • Email : support@picotech.com

EU authorized representative

  • Pico Technology GmbH
  • Ihm Rehwinkel 6
  • 30827 Garbsen
  • Germany
  • Tel : +49 (0) 5131 907 6290
  • Email : info.de@picotech.com
  • Copyright © 2018-2022 Pico Technology Ltd. All rights reserved.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals