Product Specifications

  • Model: IL519025EN
  • Brand: Cooper Lighting Solutions
  • Power Supply (Input):
    • Black (BK) – Hot
    • White (WT) – Neutral
    • Green (GN) – Ground
    • Violet (VT) – Dimming (+)
    • Pink (PK) – Dimming (-)

Product Usage Instructions

Installation Instructions
Before starting any work, ensure that all power sources are turned off. All work must meet local/national electrical codes and be performed by a certified electrician.

Mounting Information:
Refer to submittal drawings for detailed flange information. Prepare grid width spacing according to the provided chart and local building code. Install fixture housing into the grid ensuring brackets secure over grid and fixture is resting on grid tee.

Connection Instructions

  1. Unscrew the access plate and slide to remove as shown.
  2. Connect shielded cable to the access plate and electrical wiring using the provided push-in connector. Ensure wires are fully secure in connectors.
  3. Reattach access plate by sliding it back into the housing and secure it by re-installing the screw.

Frequently Asked Questions (FAQ)

  • Q: What should I do before installing the product? A: Ensure all power sources are turned off and follow local/national electrical codes. Installation should be performed by a certified electrician.
  • Q: How should I connect the electrical wiring?
    A: Connect the shielded cable to the access plate and use the provided push-in connector to connect the electrical wiring. Make sure the wires are fully secure in the connectors.

Installation Instructions

Define Gen 2 Recessed Grid / FES S122-S125

WARNING
RISK OF ELECTRIC SHOCK—Disconnect power at fuse or circuit breaker before installing or servicing.

WARNING
Risk of fire/electric shock. If not qualified, consult an electrician.

WARNING
Risk of fire or electric shock. Fixture wiring, driver, or other electrical parts may be damaged during installation. Check enclosed wiring and components.

WARNING
RISK OF PERSONAL INJURY – Fixture may become damaged and/or unstable if not installed properly.

NOTE: This product must be installed in accordance with the applicable installation code by a electrician familiar with the construction and operation of the product and hazards involved.
NOTE: Only those open holes indicated in the photographs and/or drawings may be made or altered as a result of kit installation. Do not leave any other open holes in an enclosure of wiring or electrical components.
NOTE: To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or any sharp objects.
NOTE: Disconnect all power before proceeding.

Wiring Table

COOPER-IL519025EN-Define-Recessed-Recessed-Grid- \(1\)

Installation Instructions

Define Series (122, 123, 124, 125) Individual and Continuous Luminaires For Installation in Grid Ceilings

Before starting any work, ensure that all power sources are turned off. All work must meet local/national electrical codes and be preformed by a certified electrician.

Parts List

  • Luminaire
  • Grid Bracket/Joiner (pre-installed in fixture)
  • Access Plate (pre-installed in housing)
  • Support Wire (by others)
  • Shielded Cable (by others)
  • Lens Removal Tool
  • Push-in Quick Connects or wire nuts
  • Alignment Pins (pre-installed in fixture) (Continuous runs only)
  • 8-32 2-1/2” Bolts and Nuts (Continuous runs only)

  • 9/64” Allen Wrench (by others)
  • 11/32” Flexible Nut Driver (by others)
  • 2 Phillips Screwdriver (by others)

Cross Section and Grid Spacing Details

COOPER-IL519025EN-Define-Recessed-Recessed-Grid- \(2\)

Define Cross Section Dimensions

All Grid| V (Flush)| W (Regressed)| X| Y| Z
Define 1| 1.734| 2.705| 1.500| 1.180| 2.500
Define 2| 3.500| 4.500| 2.000| 1.680| 3.000
Define 3| 4.000| 5.000| 3.000| 2.680| 4.000
Define 4| 4.506| 5.506| 4.000| 3.680| 5.000
Define 5| 5.000| 6.000| 5.000| 4.680| 6.000

Mounting Information – Extruded Trim Flange Details – Refer to submittal drawings for detailed flange information

COOPER-IL519025EN-Define-Recessed-Recessed-Grid- \(3\)

  1. Prepare grid width spacing according to chart above and local building code. Install fixture housing into grid. Ensure Grid brackets secure over grid and fixture is resting on grid tee. Unscrew access plate and slide to remove as shown.
  2. Connect shielded cable to access plate. Connect electrical wiring as required using provided push-in connector. Ensure wires are fully secure in connectors.COOPER-IL519025EN-Define-Recessed-Recessed-Grid- \(4\)
  3. Reattach access plate by sliding plate back into housing as shown and secure access plate by re-installing screw.
  4. Secure fixture at both ends using support wire according to local building codes (not supplied). COOPER-IL519025EN-Define-Recessed-Recessed-Grid- \(5\)
  5. FOR CONTINUOUS RUNS: Connect through wiring using the provided push-in connectors, pressing together until they click into place. Tuck wiring into fixture and push together ensuring alignment pins are properly connected into mating features of the next fixture. Secure run using #8-32 bolts and nuts on each side of fixture through grid brackets.
  6. FOR CONTINUOUS RUNS: Secure next fixture in row using support wires on both sides of fixture. OPTIONAL STEP: Secure fixture to grid using #8 screws through grid bracket. Required for seismic installations. Repeat steps 5-6 as necessary. COCOOPER-IL519025EN-Define-Recessed-Recessed-Grid- \(6\)
  7. FOR CORNER INSTALLATION: Prepare corner unit for installation. Identify power feed side (end toward Beginning of Run). Prep wires on power feed side for connection to previous section in the run / pat-tern. Install alignment pins into extrusion non-power feed side using a hammer. Tapered side should face outward.
  8. Installation completed. COOPER-IL519025EN-Define-Recessed-Recessed-Grid- \(7\)

Lens Removal (Not typically required)COOPER-IL519025EN-Define-Recessed-
Recessed-Grid- \(8\)

Follow the sticker label for optics that require orientation (ex. asymmetric or wall wash).

Warranties and Limitation of Liability

Please refer to www.cooperlighting.com for our terms and conditions.

Cooper Lighting Solutions

  • 1121 Highway 74 South Peachtree City, GA 30269
  • P: 770-486-4800
  • www.cooperlighting.com
  • © 2024 Cooper Lighting Solutions All Rights Reserved
  • Printed in USA

Cooper Lighting Solutions is a registered trademark.
All trademarks are property of their respective owners.
Product availability, specifications, and compliances are subject to change without notice

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Cooper User Manuals

Related Manuals