COOPER Lighting Solutions VNLW-P-1001-MV-N-W Wall Switch with Vacancy Sensor Owner’s Manual
- June 1, 2024
- COOPER Lighting Solutions
Table of Contents
- COOPER Lighting Solutions VNLW-P-1001-MV-N-W Wall Switch with Vacancy
- Product Information
- Product Usage Instructions
- FAQ
- Typical Applications
- Top Product Features
- Dimensional Details
- Scale or Mounting Height
- Order Information
- Product Specifications
- Overview
- Wiring Diagrams
- Controls
- Field of View
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
COOPER Lighting Solutions VNLW-P-1001-MV-N-W Wall Switch with Vacancy
Sensor
Product Information
Specifications:
- Product: VNLW-P Wall Switch with Vacancy Sensor
- Relay: Single 120/277 VAC Relay
- Night Light: Included (Neutral Required)
- Ratings:
- Incandescent: 0-800W @ 120V
- Fluorescent: 0-1200W @ 120V
- Fluorescent: 0-2700W @ 277V Max Load/Relay
- Voltage: 120/277 VAC, 50/60 Hz
- Colors: White (W), Ivory (V), Light Almond (LA)
- Dimensions:
- Mounting Plate: 4.195 H x 1.732 W (106.55mm x 44mm)
- Housing: 2.618 H x 1.752 W x 1.9 D (66.5mm x 44.5mm x 48.26mm)
Product Features:
- PIR Activated
- Self-Adjusting
- California Title 20 Compliant
Product Usage Instructions
Installation:
- Ensure power is turned off before installation.
- Connect the switch according to the provided wiring diagrams.
- Mount the switch on the wall using appropriate hardware.
Setting Up:
- Adjust the time delay using the DIP switches based on your preference.
- Set PIR sensitivity as needed using the DIP switches.
- You can enable or disable the night light feature using the override switch.
Cleaning and Maintenance:
Follow the recommended cleaning tips provided by Cooper Lighting Solutions to maintain the product’s integrity and finish.
FAQ
- Q: What should I do if the night light is not working?
- A: Check the override switch to ensure the night light feature is enabled. If issues persist, contact Cooper Lighting Solutions for assistance.
- Q: Can I use ammonia-based cleaners to clean the product?
- A: No, do not use ammonia-based or VOC cleaners as they can damage the product. Follow the recommended cleaning instructions provided in the manual.
VNLW-P Wall Switch with Vacancy Sensor
Wall Switch with Vacancy Sensor with a single 120/277 VAC Relay and Night Light (Neutral Required)
Typical Applications
- Private Offices
- Small Conference Rooms
- Lunch/Break Rooms
- Small Classrooms
- Small Restrooms (no stalls)
- Small Lounges
- Small Waiting Rooms
- Small Closets
- Small Storage Areas
Product Certification
Product Features
Interactive Menu
- Order Information
- Additional Resources
- Wiring Diagrams
- Product Warranty
Top Product Features
- Amber LED night light illuminates when overhead lights are OFF
- Lighting control and wall switch all-in-one that is used for energy savings and convenience
- Air-gap switch ensures no leakage current to load
- NEMA WD7 Guide robotic method utilized to verify coverage patterns
- LED Rated
Dimensional Details
Scale or Mounting Height
Order Information
One single gang wallplate is included.
Catalog Number
Catalog Number | Ratings | Coverage | Voltage | Color |
---|
VNLW-P-1001-MV-N- (-W, V, LA)
| Incandescent: 0-800W @ 120V Fluorescent: 0-1200W @ 120V Fluorescent: 0-2700W @ 277V Max Load/Relay| ****
180°; 1000 sq. ft.
| ****
120/277 VAC, 50/60 Hz
| ****
W=White, V=Ivory, LV=Light Almond
| | | | Notes
Not all colors are available in stock and some color options may have extended lead times.
Product Specifications
Technology
-
Passive Infrared (PIR)
Mechanical -
Mounting Plate Dimensions: 4.195” H x 1.732” W (106.55mm x 44mm)
-
Product Housing Dimensions: 2.618” H x 1.752” W x 1.9” D
-
(66.5mm x 44.5mm x 48.26mm)
Environment:
-
* Operating temperature: 32°F to 104°F (0°C to 40°C)
- Relative humidity operating: 20% to 90% non-condensing
- For indoor use only
- Housing: Durable, injection molded housing. ABS resin complies with UL 94V-0
- Mounting: Fits in a standard 3.5” deep back box
Electrical
- Electrical ratings:
120 VAC
- Incandescent / Tungsten max load: 6.7 amps, 800W, 50/60 Hz
- Fluorescent / Ballast max load: 10 amps, 1200W, 50/60 Hz
- Electronic Ballast (LED): 3A
- Motor Load: 1/4 HP @ 125 VAC 277VAC
- Fluorescent / Ballast max load: 9.8 amps, 2700W, 50/60Hz
- Electronic Ballast (LED): 3A
Ballast compatibility:
- LED loads
- Magnetic and Electronic ballasts
Hardware Specifications
- LED Indicators:
- Red LED = PIR detection
- Amber LED = acts as night light locator
Controls and Performance
Time delays:
- Self-adjusting 15 seconds/test, 1, 5, 15, 20, 30 minutes, 1 hour, 2 hours
Coverage:
- Major motion: 36’ x 30’
- Minor motion: 20’ x 16’
Light sensing level:
- 0 to 200-foot candles
Standards/Ratings
- cULus Listed
- FCC Compliant
- RoHS Compliant
Warning
- This product is not intended to be used in applications involving the use of ammonia-based or VOC cleaners.
- Use of ammonia-based or VOC cleaners on this device must be avoided. Prolonged use may cause loss of integrity and expose electrified components. If this occurs, turn OFF power to the unit and replace.
- For detailed cleaning guidelines please refer to: Controls Care and Maintenance instructions at the end of this document.
Warranty
Five-year warranty standard
Overview
The VNLW-P-1001-MV-N uses Passive Infrared (PIR) sensor technology to monitor a room for occupancy and deliver maximum energy savings. In Automatic On Mode, the lights turn ON when a person enters the room. In Manual On Mode, the lights are turned ON by pressing the universally recognized light icon pushbutton.The unit ships in Manual ON Mode. The night light activates when the sensor turns the lights OFF. The sensor includes self-adaptive technology that continuously self-adjusts sensitivity and time delay in real-time, maximizing the potential energy savings that are available in the particular application. PIR sensors are considered line-of-sight sensors, meaning that the sensor must be able to have a direct line-of-sight to the person making the motion
Wiring Diagrams
Single Level Switching
Three-way wiring diagram: Lights will turn OFF automatically when sensor that detected motion last, times out.
Controls
Field of View
Cooper Lighting Solutions has developed recommended guidelines for cleaning our products that will not impact the operation or finish of the product.
Recommended cleaning tips:
- Never spray any fluids directly into the device.
- Use of ammonia-based or VOC cleaners on this device must be avoided. Prolonged use may cause loss of integrity and expose electrified components. If this occurs, turn OFF power to the unit and replace.
- Use a damp rag or single-use wipe to avoid excess liquid penetrating the device.
- Be sure to wipe up the remaining excess liquid after cleaning.
- Ensure the cleaning agent used does not have harsh chemicals such as bleach, ammonia, highly alkaline or concentrated acids (such as hydrochloric acid that can be found in household cleaners such as toilet bowl cleaners, bathroom tile and porcelain cleaners) as they could damage the device, causing them to become brittle and discoloured.
- Cooper Lighting Solutions recommends the use of a mild liquid detergent and water to clean the devices. Single use wipes (e.g. Lysol brand or equivalent) are acceptable to use for cleaning the devices, however single-use wipes cannot contain bleach, ammonia, highly alkaline or concentrated acids.
Recommended cleaning instructions:
- Never spray any fluids directly into the device.
- Apply the mild liquid detergent to a damp cloth or paper towel. Single use wipes (e.g. Lysol brand or equivalent) are acceptable to use for cleaning the devices, however single-use wipes cannot contain bleach, ammonia, highly alkaline or concentrated acids.
- If excess liquid is present, remove by wringing out the cloth or paper towel to avoid liquid penetration into the device.
- Clean the Cooper Lighting Solutions device by wiping over the surface with the damp cloth.
- Remove an excess liquid remaining on the device with a dry cloth or paper towel.
WARNING
This product is not intended for use in applications involving the use of ammonia-based or VOC cleaners. Prolonged use may cause loss of integrity and expose electrified components. If this occurs, turn OFF power to the unit and replace
Cooper Lighting Solutions
- 1121 Highway 74 South
- Peachtree City, GA 30269
- P: 770-486-4800
- www.cooperlighting.com
- For service or technical assistance:
- 1-800-553-3879
- Canada Sales
- 5925 McLaughlin Road
- Mississauga, Ontario L5R 1B8
- P: 905-501-3000
- F: 905-501-3172
© 2024 Cooper Lighting Solutions All Rights Reserved. Product availability, specifications, and compliances are subject to change without notice.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>