COOPER Lighting Solutions HC6 6 Inch LED Downlight and Wall Wash Owner’s Manual

June 1, 2024
COOPER Lighting Solutions

COOPER Lighting Solutions HC6 6 Inch LED Downlight and Wall Wash

COOPER-Lighting-Solutions-HC6-6-Inch-LED-Downlight-and-Wall-Wash-
Product

Product Information

Product Specifications

  • Model: HC6 | HM6 | 61 | 61PS
  • Type: 6-inch LED downlight and wall wash
  • Dimensions: 26.4″ [670.56mm] (Module Height), 8.6″ [217.35mm] (LED Height)
  • Certifications: Product Certification

Product Usage Instructions

Control Compatibility

  • WaveLinx LITE: Compatible
  • WaveLinx PRO: Compatible

Mounting Details
Ensure the following dimensional requirements are met for proper installation:

  • Max Module Height: Refer to the provided table for specific heights
  • LED Height: Refer to the provided table for specific heights
  • Ceiling Thickness: .5″ [12.70mm]
  • Reflector Inner Aperture: 6.06″ [153.92mm]
  • Ceiling Cut Out: 7.25″ [184.15mm]
  • Trim Flange: 7.75″ [196.85mm]

Ordering Information
When ordering, consider the following options:

  • Mounting Frame: HC6 | HM6 | 61 | 61PS
  • Lumens: Choose from various lumen options as per your requirements
  • Driver Options: Select the appropriate driver based on voltage and dimming requirements

Frequently Asked Questions

Can I use the emergency battery packs with all models?

No, the emergency battery packs have specific compatibility requirements. Refer to the product manual for details.

What is the recommended spacing between adjacent luminaires?

The recommended spacing is Center to Center = 36. Please ensure proper spacing for optimal performance.

Are the WaveLinx sensor kits included with the product?

No, the WaveLinx sensor kits need to be ordered separately as accessories.

Typical Applications

  • Office
  • Healthcare
  • Hospitality
  • Institutional
  • Mixed-Use/Retail

Top Product Features

  • New construction/remodel series; 500 to 6,000 lumens
  • Narrow, Medium and Wide distributions; Wall wash with rotatable linear spread lens
  • 2700K, 3000K, 3500K, 4000K, 5000K CCT; 80 or 90 CRI
  • Universal voltage 120V-277V; Standard 0-10V driver dims to 1%
  • Mounting frame converts to remodel that installs from below the ceiling
  • Quick Spec emergency backup mounting frames – fast delivery option

COOPER-Lighting-Solutions-HC6-6-Inch-LED-Downlight-and-Wall-Wash-Fig-
\(1\)

Dimensional and Mounting Details

COOPER-Lighting-Solutions-HC6-6-Inch-LED-Downlight-and-Wall-Wash-Fig-
\(2\) COOPER-Lighting-
Solutions-HC6-6-Inch-LED-Downlight-and-Wall-Wash-Fig-
\(3\)

Mid Lumen (3000 – 4000 Lumens)


Distribution

| Max. Module Height| ****

Trim Height

| ****

LED Height

---|---|---|---
Narrow| 6.6″| 3.4”| 3.8”
Medium| 6.7”| 3.5”| 3.9”
Wide| 6.5”| 3.3”| 3.7”
Baffle| 6.5”| 3.3”| 3.7”

Order Information

Mounting Frame Order Information

Sample Number: HC620D010REM7 – HM60525835 – 61MDC
A complete luminaire consists of a housing frame, LED module, and reflector (ordered separately)

Mounting Frame| Lumens| Driver Options| Factory Installed Emergency & Connected Lighting Options| Accessories (Order & Install Separately)
---|---|---|---|---
HC6 = 6″ new construction downlight housing| 05 = 500 lm

07 = 750 lm

| D010 =UNV 120-277V, 50/60Hz, 0-10V

1%-100% dimming at 120-277V on 0-10V controls

Canada Option 500-5000 lumens: D010347 = 347VAC 50/60Hz 0-10V 1%- 100% dimming. For 500, 750, 1000, 1500,

2000, 2500, 3000, 3500, 4000, 4500,

5000lm models only ( 1)

Canada Option 5500-6000 lumens: D010X347 = step-down transformer factory installed (with standard “D010″ 120V-277V LED driver). For 5500, 6000lm

models only ( 1)

| REM7 = 7-watt emergency battery pack with remote test/indicator light, use with D010 only (1) (2) (6)| HB128APK = L channel hanger bar, 26”, pair (replacement)

RMB22 = Adjustable wood joist mounting bars, pair, extend to 22” long

HSA6 = Slope Adapter for 6” Aperture Housings, Specify Slope (refer to instructions for installing housing and trim)

H347 = 347 to 120V step down transformer, 75VA

H347200 = 347 to 120V step down transformer, 200VA

WTA = Field WaveLinx PRO Tilemount Sensor Kit (4)

WTK = Field WaveLinx LITE Tilemount Sensor Kit (5)

HC6CP = 6″ new

construction housing, Chicago Plenum – CCEA compliant

| 10 = 1000 lm

15 = 1500 lm

20 = 2000 lm

25 = 2500 lm

30 = 3000 lm

35 = 3500 lm

40 = 4000 lm

| REM14 = 14-watt emergency battery pack with remote test/indicator light, use with D010 only (1) (2) (6)

IEM7 = 7-watt emergency battery pack with integral test/indicator light, use with D010 only (1) (2) (6)

IEM14 = 14-watt emergency battery pack with integral test/indicator light, use with D010 only (1) **(2) ****(6)**

BOD7ST = 7.5 watt Bodine self-test emergency battery pack with remote test/indicator light, use with D010 only (1) (2) (6)

 | 45 = 4500 lm ( 7)| WTA = Factory WaveLinx PRO Tilemount Sensor Kit (4)
 | 50 = 5000 lm ( 7)| WTK = Factory WaveLinx LITE Tilemount Sensor Kit (5)
 | 55 = 5500 lm ( 7)| WPN = WaveLinx PRO Wireless Node without Sensor (9)
 | 60 = 6000 lm ( 7)| WLN = WaveLinx LITE Wireless Node without Sensor (10)
 |  | DLV = Distributed Low Voltage dimming driver 1%-100%, 1000-4000 lumens only. For use with DLVP system only, refer to DLVP specifications for details. ( 1)| REMV7 = 7-watt emergency battery pack with remote test/indicator light, use with DLV only (1) (2) (3) (6)

REMV14 = 14-watt emergency battery pack with remote test/indicator light, use with DLV only (1) (2) (3) (6)

 |  |  | IEMV7 = 7-watt emergency battery pack with integral test/indicator light, use with DLV only (1) (2) (3) (6)
 |  |  | IEMV14 = 14-watt emergency battery pack with integral test/indicator light, use with DLV only (1) (2) (3) (6)
Notes| Notes| Notes

(1) Not available with CP models

| Notes| Notes
 | (7) Marked Spacing:

Center to Center of Adjacent Luminaires = 36”

Center of Luminaire to Building Member = 18” Minimum overhead = 0.5

| (1) Not available with CP models

(2) Not available with D010347 (347V models)

(3) ULus for the U.S. only

(4) WTA = WaveLinx PRO tile mount sensor kit for daylight dimming, PIR motion sensing, and optional RLTS – Real Time Location Services, use with D010 only. (Refer to WaveLinx PRO specifications.)

(5) WTK = WaveLinx LITE tile mount sensor kit for daylight dimming, PIR motion sensing, use with D010 only. (Refer to WaveLinx LITE specifications.)

(6) Emergency battery backup options are Non-IC only, and rated for a minimum starting temperature of 0°C

| (4) WTA = WaveLinx PRO tile mount sensor kit for daylight dimming, PIR motion sensing, and optional RLTS – Real Time Location Services, use with D010 only. (Refer to WaveLinx PRO specifications.)

(5) WTK = WaveLinx LITE tile mount sensor kit for daylight dimming, PIR motion sensing, use with D010 only. (Refer to WaveLinx LITE specifications.)

 |  | (9) WPN = WaveLinx PRO wireless node provides luminaire-level control with scene and zone configuration without an integrated sensor; Connects wirelessly with daylight dimming sensor and PIR motion sensor if desired. Use with 0-10V driver only. Not compatible with 347V or Chicago plenum. (Refer to WaveLinx PRO specifications.)|
 |  | (10) WLN = WaveLinx LITE wireless node provides luminaire-level control with scene and zone configuration without an integrated sensor; Connects wirelessly with daylight dimming sensor and PIR motion sensor if desired. Use with 0-10V driver only. Not compatible with 347V or Chicago plenum. (Refer to WaveLinx LITE specifications.)|

Quick Spec Emergency Mounting Frame Order Information

Sample Number:
Quick Spec Emergency Mounting Frame: RR-HC620D010REM7

  • LED modules and reflectors are ordered separately.
  • Order separately: LED Module: HM60525835 | Reflector: 61MDC

Select from the Quick Spec Mounting Frame ordering information to receive the Fast Delivery option for the frame.

Quick Spec Code

|

Mounting Frame

|

Lumens

|

Driver Options

| Factory Installed Emergency & Connected Lighting Options| Accessories

(Order & Install Separately)

---|---|---|---|---|---
RR = East Region

BRR = West Region

| HC6 = 6″ new construction downlight housing| 10 = 1000 lm

15 = 1500 lm

20 = 2000 lm

30 = 3000 lm

40 = 4000 lm

| D010 =UNV 120-277V, 50/60Hz, 0-10V

1%-100% dimming at 120-277V on 0-10V controls

| REM7 = 7-watt emergency battery pack with remote test/indicator light, use with D010 only (2) (6)

REM14 = 14-watt emergency battery pack with remote test/indicator light, use with D010 only (2) (6)

IEM7 = 7-watt emergency battery pack with integral test/indicator light, use with D010 only (2) (6)

IEM14 = 14-watt emergency battery pack with integral test/indicator light, use with D010 only (2) (6)

| HB128APK = L channel hanger bar, 26”, pair (replacement) RMB22 = Adjustable wood joist

mounting bars, pair, extend to

22” long

Notes| Notes| Notes| Notes| Notes

(2) Not available with D010347 (347V models)

(6) Emergency battery backup options are Non-IC only, and rated for a minimum starting temperature of 0°C

| Notes

LED Module Order Information

LED Module Lumens CRI/CCT
HM6 = 6″ LED Modules 0525 = 500 – 2500 lumen 827 = 80CRI,
2700K 927 = 90CRI, 2700K
For use with HC6 – HC6CP New Construction housings only 3040 = 3000-4000

lumen

4560 = 4500-6000 lumen

| 830 = 80CRI, 3000K

835 = 80CRI, 3500K

840 = 80CRI, 4000K

| 930 = 90CRI, 3000K

935 = 90CRI, 3500K

940 = 90CRI, 4000K

 |  | 850 = 80CRI, 5000K| 950 = 90CRI, 5000K
Notes| Notes| Notes

Trim Order Information

Reflector| Distribution (8)| Finish| Flange| Accessories
---|---|---|---|---
61 = 6” conical reflector| ND = narrow 55° beam angle 0.97 SC MD = medium 60° beam angle 1.10 SC WD = wide 65° beam angle 1.28 SC RWW = rotatable wall wash with linear spread lens| C = Specular clear

H = Semi-specular clear

W = White

| Blank = Polished flange standard with C & H reflectors

Blank = White flange standard with W reflector

WF = White flange option available with C & H reflectors

| 61RWWPK = Replacement part kit – wall wash lens insert – for use with 61RWW* only.
Notes| Notes

(8) Values are nominal, with specular clear reflector, other finishes and field results may vary.

| Notes| Notes| Notes
Baffle| Distribution (8)| Finish| Flange| Accessories
---|---|---|---|---
61 = 6” baffle reflector| WD = wide 65° beam angle 1.28 SC (nominal)

RWW = rotatable wall wash with linear spread lens

| BB = Black baffle

WB = White baffle

| Blank = White flange standard with BB, & WB

BF = Black flange option available with BB

| 61RWWPK = Replacement part kit – wall wash lens insert – for use with 61RWW* only.
Notes| Notes

(8) Values are nominal, with specular clear reflector, other finishes and field results may vary.

| Notes| Notes| Notes
Reflector| Distribution (8)| Finish| Flange
---|---|---|---
61PS = 6” non-conductive polymer ‘dead front’ conical reflector (9)| MD = medium 60° beam angle 1.10 SC (nominal)| W = White| Blank = White flange standard with W reflector
Notes

(9) 61PS is 1000-2000 lumens Non-IC rated. 500 & 750 lumens IC rated. 61PS is not for use over 2000lm in non-IC or over 750lm in IC.

| Notes

(8) Values are nominal, with specular clear reflector, other finishes and field results may vary.

| Notes| Notes
IEM Reflector| Distribution (8)| Finish| Flange| Integral Emergency
---|---|---|---|---
61 = 6” IEM reflector for integral emergency only| ND = narrow 55° beam angle 0.97 SC MD = medium 60° beam angle 1.10 SC WD = wide 65° beam angle 1.28 SC| C = Specular clear

H = Semi-specular clear

W = White

| Blank = Polished flange standard with C & H reflectors Blank = White flange standard with W reflector

WF = White flange option available with C & H reflectors

| IEM = Reflector for use with integral emergency housings only. Provides access hole for integral emergency test switch.
Notes| Notes

(8) Values are nominal, with specular clear reflector, other finishes and field results may vary.

| Notes| Notes| Notes
IEM Baffle| Distribution (8)| Finish| Flange| Integral Emergency
---|---|---|---|---
61 = 6” IEM baffle reflector for integral emergency only| WD = wide 65° beam angle 1.28 SC (nominal)| BB = Black baffle

WB = White baffle

| Blank = White flange standard with BB, & WB

BF = Black flange option with BB

| IEM = Reflector for use with integral emergency housings only. Provides access hole for integral emergency test switch.
Notes| Notes

(8) Values are nominal, with specular clear reflector, other finishes and field results may vary.

| Notes| Notes| Notes

Product Specifications

Housing Frame

  • Boat-shaped galvanized steel plaster frame with adjustable plaster lip
  • Accommodates 1/2″ to 1-1/2″ thick ceilings
  • Installs in new construction or from below the finished ceiling (non-accessible) for remodelling (with mounting bars removed)
  • Provided with two remodel clips to secure the frame to the ceiling

Universal Mounting Bracket

  • Adjusts 2″ vertically from above and below the ceiling
  • Use with the included mounting bars or with a 1/2″ Electric Metallic Tube (EMT)
  • Removable to facilitate remodelling installation from below the finished ceiling

Mounting Bars

  • Captive pre-installed No Fuss™ mounting bars lock to T-grid with screwdriver or pliers
  • Centring detents allow for consistent positioning of fixtures

LED Module

  • Proximity phosphors over chip-on-board LEDs provide a uniform source with high efficiency and no pixelation
  • Available in 80 or 90 colour rendering index (CRI)
  • Colour accuracy within 3 SDCM provides colour consistency and uniformity
  • 90 CRI option: R9>50 (refer to chromaticity information for details)
  • Available in 2700K, 3000K, 3500K, 4000K and 5000K correlated color temperature (CCT)
  • Lumen options include 500, 750, 1000, 1500, 2000, 2500, 3000, 3500, 4000, 4500, 5000, 5500, 6000 lumens (nominal)
  • Passive thermal management achieves 60,000 hours at 70% lumen maintenance (L70) in insulated ceilings (IC) and non-IC applications
  • Integral diffuse lens provides visual shielding
  • Integral connector allows quick connection to housing flex

Reflector

  • Self-flanged aluminium reflectors available in narrow, medium or wide distribution patterns
  • Medium distribution polymer non-conductive matte white reflector may be used to meet local codes for ‘dead front’ applications (500 & 750-lumen max. in IC and 2000 lumen max. in Non-IC)
  • Wall wash reflector features a rotatable linear spread lens for alignment of vertical illumination
  • Reflectors attach to LED module with three-speed clamps
  • Available in multiple painted or plated finishes

Reflector/Module Retention
Reflector/module assembly is securely retained in the housing with two torsion springs

Driver

  • The field-replaceable constant current driver provides low-noise operation
  • Universal 120-277VAC 50/60Hz input standard
  • Continuous, 1% to 100% dimming with 0-10V analog control
  • Optional low-voltage DC driver for use with Distributed Low Voltage Power (DLVP) system
  • Distributed Low Voltage Power (DLVP) system combines power, lighting and controls with ease of installation (refer to DLVP Design Guide at www.cooperlighting.com for details)

Canada Options

  • 347VAC 50/60Hz; 1% dimming on 0 -10V analog control, for 500, 750, 1000, 1500, 2000, 2500, 3000, 3500, 4000, 4500, and 5000-lumen models only
  • 347V step down transformer factory installed with the standard “D010” 120V-277V, LED driver on 5500, 6000 lumen models only

Emergency Option

  • Provides 90 minutes of standby lighting, meeting most life safety codes for egress lighting
  • Available with integral or remote charge indicator and test switch
  • Available Self-Test (self-diagnostic) with remote charge indicator and test switch
  • Quick Spec emergency ordering option for quick-turn projects

Connected Lighting System
Two WaveLinx-connected solutions to choose from. Refer to WaveLinx system specifications and application guides for details.

WaveLinx PRO Tilemount Sensor Kit

  • WaveLinx PRO WTA tilemount sensor kit offers daylight dimming, PIR motion sensing, scene and zone configuration, automatic commissioning; and optional RLTS – Real Time Location Services available.

WaveLinx PRO Wireless Node

  • WaveLinx PRO WPN wireless node provides luminaire-level control with scene and zone configuration without an integrated sensor; Connects wirelessly with daylight dimming sensor and PIR motion sensor if desired. Use with 0-10V driver only. Note: Not compatible with 347V or Chicago plenum.

WaveLinx LITE Tilemount Sensor Kit

  • WaveLinx LITE WTK tilemount sensor kit offers daylight dimming and PIR motion sensing, scene and grouping configuration.

WaveLinx LITE Wireless Node

  • WaveLinx LITE WLN wireless node provides luminaire level control with scene and zone configuration without an integrated sensor; Connects wirelessly with daylight dimming sensor and PIR motion sensor if desired. Use with 0-10V driver only.

Note: Not compatible with 347V or Chicago plenum.

WaveLinx Tilemount Sensor Kits Application

  • The WTA and WTK tilemount sensor kits include a control module mounted on the luminaire junction box via 1/2” knock-out and a tilemount sensor on a 54-inch whip; for ceiling installation by direct-mount spring clips or via mounting bracket in octagon ceiling boxes.
  • The WTA and WTK tilemount sensor kits may be ordered as factory-installed on the luminaire or ordered separately as a field-installed accessory kit.
  • Note: WaveLinx PRO devices are only compatible with the WaveLinx PRO system.
  • Note: WaveLinx LITE devices are only compatible with the WaveLinx LITE system.

Junction Box

  • Galvanized steel junction box
  • 20 in3 internal volume excluding voltage barrier
  • 25 in3 internal total volume
  • Voltage barrier for 0-10V dimming wires (occupies one 1/2″ pry-out space)
  • Listed for eight #12 AWG (four in, four out) 90˚C conductors and feed-thru branch wiring
  • Three 1/2″ and two 3/4″ trade size pry-outs available
  • Three 4-port push wire nuts for mains voltage with 1-port for fixture connection

Compliance

  • cULus Certified to UL 1598 / C22.2 No. 250.0, suitable for damp locations and wet locations in covered ceilings only
  • Emergency options provided with UL Listed emergency drivers to UL 924 / C22.2 No. 141, suitable for indoor/damp locations
  • IP20 – Above finished ceiling; IP65 – Below finished ceiling
  • Non-Insulated ceiling (Non-IC) rated for 2500, 3000, 3500, 4000, 4500, 5000, 5500, 6000-lumen models (insulation must be kept 3″ from top and sides)
  • Insulated ceiling (IC) rated for 500, 750, 1000, 1500, and 2000 lumen models and suitable for direct contact with air permeable insulation* (IC models are also suitable for Non-IC installations)
  • Non-IC marked spacingis  required for 4500, 5000, 55 00, and  6000-lumen models
    • Marked Spacing Center to Center of Adjacent Luminaires = 36”
    • Centre of Luminaire to Building Member = 18”
    • Minimum overhead = 0.5”
  • Airtight per ASTM-E283-04
  • Suitable for use in clothes closets when installed by the NEC 410.16 spacing requirements
  • EMI/RFI emissions FCC CFR Title 47 Part 15 Class A at 120/277V
  • Contains no mercury or lead and RoHS compliant
  • Photometric testing completed by IES LM-79-08
  • Lumen maintenance projection in accordance with IES LM-80-08 and TM-21-11
  • 500, 750, 1,000, 1,500 and 2,000 lumen, 90 CRI, ICAT models may be used to comply with the State of California Title 24 residential code, per JA8 certification standards
  • May be used to comply with the State of California Title 24 non-residential code as a dimmable LED luminaire
  • ENERGY STAR® certified, reference-certified light fixtures database

Not for use in direct contact with spray foam insulation, consult NEMA LSD57-2013

Photometric Data

NARROW DISTRIBUTION – SPECULAR CLEAR FINISH, 2000 LUMEN MODEL, 80 CRI, 3500K

COOPER-Lighting-Solutions-HC6-6-Inch-LED-Downlight-and-Wall-Wash-Fig-
\(4\) COOPER-Lighting-
Solutions-HC6-6-Inch-LED-Downlight-and-Wall-Wash-Fig-
\(5\)

MEDIUM DISTRIBUTION – SPECULAR CLEAR FINISH, 2000 LUMEN MODEL, 80 CRI, 3500K

COOPER-Lighting-Solutions-HC6-6-Inch-LED-Downlight-and-Wall-Wash-Fig-
\(6\) COOPER-Lighting-
Solutions-HC6-6-Inch-LED-Downlight-and-Wall-Wash-Fig-
\(7\)

WIDE DISTRIBUTION – SPECULAR CLEAR FINISH, 2000 LUMEN MODEL, 80 CRI, 3500K

COOPER-Lighting-Solutions-HC6-6-Inch-LED-Downlight-and-Wall-Wash-Fig-
\(8\) COOPER-Lighting-
Solutions-HC6-6-Inch-LED-Downlight-and-Wall-Wash-Fig-
\(9\)

  • Value is nominal with specular clear reflectors, other finishes and field results may vary.
  • SC = Spacing Criteria
  • UGR = Unified Glare Rating

Photometric Multipliers (Nominal Lumen Values)

500 Lumen| 750 Lumen| 1000 Lumen| 1500 Lumen| 2000 Lumen| 2500 Lumen| 3000 Lumen| 3500 Lumen
---|---|---|---|---|---|---|---
0.33| 0.44| 0.54| 0.74| 1.00| 1.12| 1.46| 1.76
4000 Lumen| 4500 Lumen| 5000 Lumen| 5500 Lumen| 6000 Lumen
---|---|---|---|---
1.81| 2.17| 2.28| 2.38| 2.65

Multipliers for relative lumen values with other series models.

Color Finish Multipliers

Finish code C H W/WB BB

Finish

| ****

Specular Clear

| ****

Semi-Specular

| Matte White White Baffle| ****

Black Baffle

Multiplier| 1.00| 0.92| 0.91| 0.82

Multipliers for relative lumen values with other colour finishes.

CCT Multipliers – 80CRI

2700K 3000K 3500K 4000K 5 000K
0.92 0.98 1.00 1.03 1 .03

Multipliers for relative lumen values with other series colour temperatures.

CCT Multipliers – 90CRI

2700K 3000K 3500K 4000K 5 000K
0.77 0.84 0.89 0.90 0 .90

Multipliers for relative lumen values with other series colour temperatures.

WALL WASH DISTRIBUTION N – SPECULAR CLEAR FINISH, 2000 LUMEN MODEL, 80 CRI, 3500K

COOPER-Lighting-Solutions-HC6-6-Inch-LED-Downlight-and-Wall-Wash-Fig-
\(10\)

CANDELA TABLE

Degrees Vertical| Candela
0| 1080
5| 1081
15| 1112
25| 1034
35| 800
45| 514
55| 319
65| 184
75| 85
85| 12
90| 0
ZONAL LUMEN SUMMARY

Zone| Lumens| % Fixture
0-30| 849| 39
0-40| 1313| 60.2
0-60| 1978| 90.8
0-90| 2179| 100
90-180| 0| 0
0-180| 2179| 100
LUMINANCE

Average Candela Degrees| Average 0° Luminance
45| 39810
55| 30479
65| 23907
75| 17983
85| 7359

SC = Spacing Criteria, nominal for specular clear reflector, other finishes and field results may vary.

SINGLE UNIT FOOTCANDLES


1| 19.3| 13.8| 6.1| 2.2| 0.7| 0.3| 0.1
2| 29.1| 22.6| 12.3| 5.7| 2.5| 1.2| 0.6
3| 27.6| 22.5| 13.8| 7.3| 3.7| 1.9| 1
4| 21| 18.2| 12.4| 7.4| 4.2| 2.4| 1.4
5| 14.4| 13.1| 9.9| 6.6| 4.1| 2.5| 1.6
6| 9.7| 9.1| 7.5| 5.5| 3.7| 2.5| 1.6
7| 6.7| 6.4| 5.5| 4.3| 3.2| 2.2| 1.5
8| 4.7| 4.6| 4.1| 3.4| 2.7| 2| 1.4
9| 3.4| 3.3| 3.1| 2.7| 2.2| 1.7| 1.3
10| 2.5| 2.5| 2.4| 2.1| 1.8| 1.4| 1.1

MULTIPLE UNIT FOOTCANDLES

MULTIPLE UNIT FOOTCANDLES

|  |
1| 21.5| 19.1| 21.5| 20| 12.1| 20
2| 34.7| 34.4| 34.7| 31.6| 24.6| 31.6
3| 34.9| 36| 34.9| 31.3| 27.6| 31.3
4| 28.4| 30.7| 28.4| 25.2| 24.8| 25.2
5| 21| 23.2| 21| 18.6| 19.8| 18.6
6| 15.2| 16.8| 15.2| 13.4| 15| 13.4
7| 11| 12| 11| 9.9| 11| 9.9
8| 8.1| 8.7| 8.1| 7.4| 8.2| 7.4
9| 6.1| 6.5| 6.1| 5.6| 6.2| 5.6
10| 4.6| 4.9| 4.6| 4.3| 4.7| 4.3

Photometric Multipliers (Nominal Lumen Values)

500 Lumen| 750 Lumen| 1000 Lumen| 1500 Lumen| 2000 Lumen| 2500 Lumen| 3000 Lumen| 3500 Lumen
---|---|---|---|---|---|---|---
0.33| 0.44| 0.54| 0.74| 1.00| 1.12| 1.46| 1.76
4000 Lumen| 4500 Lumen| 5000 Lumen| 5500 Lumen| 6000 Lumen
---|---|---|---|---
1.81| 2.17| 2.28| 2.38| 2.65

Multipliers for relative lumen values with other series models.

Color Finish Multipliers

Finish code C H W/WB BB

Finish

| ****

Specular Clear

| ****

Semi-Specular

| Matte White White Baffle| ****

Black Baffle

Multiplier| 1.00| 0.92| 0.91| 0.82

Multipliers for relative lumen values with other colour finishes.

CCT Multipliers – 80CRI

2700K 3000K 3500K 4000K 5000K
0.92 0.98 1.00 1.03 1.03

Multipliers for relative lumen values with other series colour temperatures.

CCT Multipliers – 90CRI

2700K 3000K 3500K 4000K 5000K
0.77 0.84 0.89 0.90 0.90

Multipliers for relative lumen values with other series colour temperatures.

Energy & Performance Data

COLOR METRICS – TM-30-15 & CRI/CIE (3500K)

**80 CRI Color Metric Summary – 3500K***

COOPER-Lighting-Solutions-HC6-6-Inch-LED-Downlight-and-Wall-Wash-Fig-
\(14\)

**90 CRI Color Metric Summary – 3500K***

COOPER-Lighting-Solutions-HC6-6-Inch-LED-Downlight-and-Wall-Wash-Fig-
\(15\)

Colour values are based on the 61WDWB reflector, other finishes and field results may vary.

ENERGY DATA

Series| 500 lumen| 750 lumen| 1000 lumen| 1500 lumen| 2000 lumen
---|---|---|---|---|---
Input Voltage 120-277VAC| 120V| 277V| 120V| 277V| 120V| 277V| 120V| 277V| 120V| 277V
Input Current (A)| 0.051| 0.026| 0.067| 0.036| 0.083| 0.039| 0.119| 0.053| 0.171| 0.077
Input Power (W)| 6.1| 6.5| 7.9| 8.3| 10| 10.4| 14.5| 14.5| 20.9| 20.6
In-rush (A)| 1.9| 8.4| 2| 8.4| 2.2| 8.5| 2.7| 8.5| 2.1| 9.7
Inrush duration (µs)| 251| 135| 237| 133| 250| 134| 250| 139| 245| 131
THD (%)| 6.2| 13.5| 7.4| 8.8| 5.4| 10.3| 10| 6.7| 6.5| 7.9
PF| ≥ 0.99| ≥ 0.9| ≥ 0.98| ≥ 0.92| ≥ 0.99| ≥ 0.95| ≥ 0.99| ≥ 0.97| ≥ 0.99| ≥ 0.96
Series| 2500 lumen| 3000 lumen| 3500 lumen| 4000 lumen| 4500 lumen
---|---|---|---|---|---
Input Voltage 120-277VAC| 120V| 277V| 120V| 277V| 120V| 277V| 120V| 277V| 120V| 277V
Input Current (A)| 0.23| 0.103| 0.24| 0.107| 0.292| 0.152| 0.351| 0.159| 0.384| 0.172
Input Power (W)| 27.5| 27.5| 28.6| 28.5| 34.6| 35.1| 42.1| 42.1| 45.9| 45.6
In-rush (A)| 2.5| 5.6| 2.5| 11.6| 3.4| 13.9| 3.1| 14.7| 3.1| 14.8
Inrush duration (µs)| 232| 123| 216| 111| 183| 95| 200| 98| 202| 100
THD (%)| 6.5| 8.1| 7.8| 8.3| 5.6| 10| 4.1| 9.5| 4.5| 8.5
PF| ≥ 0.99| ≥ 0.96| ≥ 0.99| ≥ 0.96| ≥ 0.99| ≥ 0.93| ≥ 0.99| ≥ 0.94| ≥ 0.99| ≥ 0.95
Series| 5000 lumen| 5500 lumen| 6000 lumen
---|---|---|---
Input Voltage 120-277VAC| 120V| 277V| 120V| 277V| 120V| 277V
Input Current (A)| 0.419| 0.186| 0.457| 0.201| 0.489| 0.214
Input Power (W)| 50.1| 49.5| 54.6| 53.7| 58.4| 57.4
In-rush (A)| 3.1| 15| 3.2| 14.8| 3.4| 14.8
Inrush duration (µs)| 202| 117| 196| 131| 192| 121
THD (%)| 5.5| 7.6| 7| 7.2| 8.1| 7.2
PF| ≥ 0.99| ≥ 0.96| ≥ 0.99| ≥ 0.96| ≥ 0.99| ≥ 0.97

  • Minimum starting temperature -30°C (-22°F)*
  • (Nominal input 120-277VAC & 100% of rated output power)
  • Sound Rating: Class A standards

Notes:
Emergency Battery packs are rated for a minimum starting temperature of 0°C.

Dimensional and Mounting Details

NEW CONSTRUCTIONS – LOW LUMEN 500 – 2500 LUMENS

COOPER-Lighting-Solutions-HC6-6-Inch-LED-Downlight-and-Wall-Wash-Fig-
\(16\)

**Low Lumen (500 – 2500 Lumens)***


Distribution

| Max. Module Height| ****

Trim Height

| ****

LED Height

---|---|---|---
Narrow| 4.5″| 3.4”| 3.8”
Medium| 4.6”| 3.5”| 3.9”
Wide| 4.4”| 3.3”| 3.7”
Baffle| 4.4”| 3.3”| 3.7”

Max. height w/removable hanger bar bracket 4.2”

NEW CONSTRUCTIONS – MID LUMEN 3000 – 4000 LUMENS

COOPER-Lighting-Solutions-HC6-6-Inch-LED-Downlight-and-Wall-Wash-Fig-
\(18\)

Mid Lumen (3000 – 4000 Lumens)


Distribution

| Max. Module Height| ****

Trim Height

| ****

LED Height

---|---|---|---
Narrow| 6.6″| 3.4”| 3.8”
Medium| 6.7”| 3.5”| 3.9”
Wide| 6.5”| 3.3”| 3.7”
Baffle| 6.5”| 3.3”| 3.7”

NEW CONSTRUCTIONS – HIGH LUMEN 4500 – 6000 LUMENS

COOPER-Lighting-Solutions-HC6-6-Inch-LED-Downlight-and-Wall-Wash-Fig-
\(20\)

High Lumen (4500 – 6000 Lumens)

Distribution

| Max. Module Height|

Trim Height

|

LED Height

---|---|---|---
Narrow| 6.9″| 3.4”| 3.8”
Medium| 7.0”| 3.5”| 3.9”
Wide|

6.8”

|

3.3”

|

3.7”

Baffle| 6.8”| 3.3”| 3.7”

Connected Solutions

WaveLinx LITE – WTK Tilemount Sensor

  • Intuitive Android™ or Apple® iOS® app for basic system code compliant set-up and configuration via Bluetooth
  • Up to 28 unique areas per project site (WaveLinx LITE Bluetooth network)
  • Up to 50 devices for an area, any one of 16 control zones, up to 6 occupancy sets, and custom lighting scenes
  • Automatic occupancy or vacancy, sensor sensitivity, daylight dimming, etc. configurable through the app
  • Refer to the WaveLinx system specifications for details

COOPER-Lighting-Solutions-HC6-6-Inch-LED-Downlight-and-Wall-Wash-Fig-
\(23\)

WaveLinx LITE WTK Tilemount Wiring Diagram

WaveLinx LITE devices are only compatible with the WaveLinx LITE system.

COOPER-Lighting-Solutions-HC6-6-Inch-LED-Downlight-and-Wall-Wash-Fig-
\(24\)

WaveLinx LITE Bluetooth Enabled System

COOPER-Lighting-Solutions-HC6-6-Inch-LED-Downlight-and-Wall-Wash-Fig-
\(25\)

WaveLinx PRO – WTA Tilemount Sensor

WaveLinx PRO devices are only compatible with the WaveLinx PRO system.

  • WaveLinx PRO tile mount functionality configures zones and customizes settings from one secure mobile app
  • Automatic code commissioning that meets the strictest codes
  • Fixtures and sensors integrate with Wireless Area Controllers, Wall Stations, and Control Devices
  • Stand-alone offices or Entire Building Network Installations

COOPER-Lighting-Solutions-HC6-6-Inch-LED-Downlight-and-Wall-Wash-Fig-
\(27\)

WaveLinx mobile app settings

COOPER-Lighting-Solutions-HC6-6-Inch-LED-Downlight-and-Wall-Wash-Fig-
\(28\)

WaveLinx WTA Tilemount Wiring Diagram

COOPER-Lighting-Solutions-HC6-6-Inch-LED-Downlight-and-Wall-Wash-Fig-
\(29\)

WaveLinx CORE Building Management Integration

COOPER-Lighting-Solutions-HC6-6-Inch-LED-Downlight-and-Wall-Wash-Fig-
\(30\)

WaveLinx LITE Wireless Node – WLN

WaveLinx LITE devices are only compatible with the WaveLinx LITE system.

  • Intuitive Android™ or Apple® iOS® app for basic system code compliant set-up and configuration via Bluetooth
  • Up to 28 unique areas per project site (WaveLinx LITE Bluetooth network)
  • Up to 50 devices for an area, any one of 16 control zones, up to 6 occupancy sets, and custom lighting scenes
  • Refer to the WaveLinx system specifications for details

WaveLinx mobile app settings

COOPER-Lighting-Solutions-HC6-6-Inch-LED-Downlight-and-Wall-Wash-Fig-
\(32\)

WaveLinx LITE Wireless Node (WLN) Wiring Diagram

COOPER-Lighting-Solutions-HC6-6-Inch-LED-Downlight-and-Wall-Wash-Fig-
\(33\)

WaveLinx LITE Bluetooth Enabled System

COOPER-Lighting-Solutions-HC6-6-Inch-LED-Downlight-and-Wall-Wash-Fig-
\(34\)

WaveLinx PRO Wireless Node – WPN

WaveLinx PRO devices are only compatible with the WaveLinx PRO system.

  • WaveLinx Wireless functionality configures zones and customizes settings from one secure mobile app
  • Automatic code commissioning that meets the strictest codes
  • Fixtures and sensors integrate with WaveLinx Area Controller, Wall Stations, and Control Devices
  • Stand-alone offices or Entire Building Network Installations

COOPER-Lighting-Solutions-HC6-6-Inch-LED-Downlight-and-Wall-Wash-Fig-
\(36\)

WaveLinx mobile app settings

COOPER-Lighting-Solutions-HC6-6-Inch-LED-Downlight-and-Wall-Wash-Fig-
\(37\)

WaveLinx PRO Wireless Node (WPN) Wiring Diagram

COOPER-Lighting-Solutions-HC6-6-Inch-LED-Downlight-and-Wall-Wash-Fig-
\(38\)

WaveLinx CORE Building Management Integration

COOPER-Lighting-Solutions-HC6-6-Inch-LED-Downlight-and-Wall-Wash-Fig-
\(39\)

Warranty

Five-year limited warranty, consult the website for details. www.cooperlighting.com/legal.

Cooper Lighting Solutions

© 2024 Cooper Lighting Solutions All Rights Reserved.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

COOPER Lighting Solutions User Manuals

Related Manuals