BEGA 50415.1K3 Ceiling Mounted Downlight Instruction Manual
- June 1, 2024
- BEGA
Table of Contents
BEGA 50415.1K3 Ceiling Mounted Downlight
Instructions for use
DIMENSIONS
Application
Compact downlight · indoor luminaire with asymmetrical wide beam light
distribution.
Product description
Die-cast aluminium and aluminium housing, finish colour white Safety glass
with optical structure Silicone gasket
Reflector surface made of pure aluminium 2 mounting holes ø 4.8mm
Distance apart 105mm
2 cable entries for through-wiring of mains supply cable ø 7-10.5mm, max.
5G1.5@ Connection terminal 2.5@ Earth conductor connection 2-pole connecting
terminal for digital control BEGA Ultimate Driver®
Complies with flicker requirements in accordance with IEEE 1789, DIN IEC/TR
63158, DIN IEC/TR 61547-1
LED power supply unit
220-240 V 0/50-60 Hz
DC 176-276 V DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables
BEGA Thermal Control® Temporary thermal regulation to protect temperature-
sensitive components without switching off the luminaire
Safety class I
Protection class IP 65
Dust-tight and protection against water jets Impact strength IK07 Protection
against mechanical impacts < 2 joule
– Safety mark
**– Conformity mark
Weight:** 1.6 kg
This product contains light sources of energy efficiency class(es) D
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend
separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
Module connected wattage 17.5 W
Luminaire connected wattage 19.7 W
Rated temperature ta=25 °C
Ambient temperature ta max =35 °C
50 415.1K3
Module designation LED-0586/930
Colour temperature 3000 K
Colour rendering index CRI >90
Module luminous flux 2590 lm
Luminaire luminous flux 1586 lm
Luminaire luminous efficiency 80,5 lm/W
50 415.1K4
Module designation LED-0586/940
Colour temperature 4000 K
Colour rendering index CRI >90
Module luminous flux 2695 lm
Luminaire luminous flux 1651 lm
Luminaire luminous efficiency 83,8 lm/W
Lighting technology
Half beam angle 44/48°
Installation
Undo the screws and lift off the luminaire top.
LED are high-quality electronic components! Please avoid touching the light
output opening of the LED directly during installation or relamping.
Lead the mains supply cable through the cable entry into the luminaire back
housing. Ensure correct directionality towards the area to be illuminated.
Fix luminaire base with enclosed or any other suitable fixing material onto
the mounting surface.
Be sure to use the gasket rings supplied. Make earth conductor connection.
Push silicone sleeves over the lines and make electrical connection.
For digital control please use the connecting terminal DA, DA.
In case this terminal is not used the luminaire will be operated at full light
output.
Make earth conductor connection between luminaire top and luminaire base.
Push plug into coupler as far as it will go. Install the luminaire top, press-
on and tighten screws evenly
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a separate label in the
luminaire or on the underside of the specific LED module.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.
Spares
LED power supply unit DEV-0312/500
LED module 3000 K LED-0586/930
LED module 4000 K LED-0586/940
Reflector 76 001 549 .A
Gasket 83 001 571
CUSTOMER SUPPORT
BEGA Gantenbrink-Leuchten KG
Postfach 3160
58689 Menden
info@bega.com
www.bega.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>