NOVATEK F2100 Negative Air Machine
Specifications:
- Model: F2100, F2102, F2105
- Product Name: Novair 2000 Negative Air Machine
- Manufacturer: NOVATEK Corporation
- Country of Origin: United States of America
Product Usage Instructions
Placing Machine in Service:
- Ensure the product is in accordance with all applicable standards and regulations.
- Avoid placing the machine near liquid hazards.
- Use a grounded outlet with a recessed male plug for power connection.
- Make sure to inform others of the machine’s location, especially if flammable liquids are present.
Using the Machine:
- Keep loose objects away from the machine’s blower assembly and Air Intake.
- Use appropriate personal protective equipment based on the work being performed.
- Do not operate the machine under the influence of medication, drugs, or alcohol.
© Copyright 2011 by NOVATEK Corporation
All rights reserved printed in the United States of America. No part of this
manual may be used or reproduced in any form or by any means, stored in data
base or retrieval system, without prior written permission from NOVATEK
Corporation.
Making copies of this manual for any purpose other than your own personal use
is a violation of the United States copyright laws.
Specifications subject to changes without notice!
If you have any questions,
- please contact us: NOVATEK CORORATION 254 Welsh Pool Rd Exton, PA 19341USA www.novatekco.com
- Toll Free 866 563-7800
- Telephone: +1 610 363-7800
- Fax +1 610 363-9620
- Email: Sales@Novatekco.com
NOTICE
FOR PROFESSIONAL USE ONLY
WARNING
- IMPORTANT SAFETY INFORMATION ENCLOSED.
- READ AND UNDERSTAND THIS MANUAL BEFORE OPERATING THIS PRODUCT.
- IT IS YOUR RESPONSIBILITY TO MAKE THIS SAFETY INFORMATION AVAILABLE TO OTHERS THAT WILL OPERATE THIS PRODUCT.
- FAILURE TO OBSERVE THE FOLLOWING WARNING COULD RESULT IN INJURY.
PLACING MACHINE IN SERVICE
- Always install, operate, inspect and maintain this product in accordance with all applicable standards and regulations (local, state, country, federal, etc.).
- Always use proper gauge cord with correct connections.
- Be sure all cords are securely connected to the recessed male plug.
- Ensure an accessible emergency shutoff when your machine is connected to power. Make others aware of its location.
- Do not use damaged, frayed, or deteriorated electrical cords or connections.
- Do not leave machines in operation unattended for any reason.
- Keep all electrical connections clear of water or other liquid hazards.
- Always turn off and unplug your machine before performing any maintenance.
- Do not operate the machine while flammable or volatile liquids such as gasoline, diesel or jet fuel are present. Failure to do so can result in explosion.
- Keep work area clean, uncluttered and illuminated.
- Do not remove any labels. Replace any damaged labels.
USING THE MACHINE
-
Always wear protection when operating or performing maintenance.
-
Always use Personal Protective Equipment appropriate to the work being performed. This may include dust mask or other breathing apparatus, safety glasses, ear plugs, gloves, apron, safety shoes, hard hat and other equipment.
-
If applicable, prevent exposure and breathing of harmful dust and particles:
Some dust created by power sanding, sawing, and grinding, drilling, and other construction activities contains chemicals known to cause cancer, birth defects or other reproductive harm. Some examples of these chemicals are:- Lead from lead based paints,
- Crystalline silica from bricks and cement and other masonry products, and
- Arsenic and chromium from chemically treated lumber
Your risk from these exposures varies, depending on how often you do this type of work.
-
Keep others a safe distance from your work area, or ensure they use appropriate Personal Protective Equipment.
-
This machine is not designed for working in explosive environments, including those caused by fumes and dust, or near flammable materials.
-
Keep hands, loose clothing, long hair and jewelry away from the machines blower assembly and “Air Intake.”
-
To avoid accidental starting – ensure machine is on the “off” position before connecting to power.
-
Do not carry or drag the machine by the cord.
-
Do not operate or maintain the machine under the influence of medication, drugs, or alcohol.
-
Never use damaged or malfunctioning machines.
-
Do not modify the machine, safety devices, or accessories.
-
Do not use this machine for purpose other than those recommended.
-
Only use accessories recommended by Novatek Corp.
-
Whenever applicable, wear safety shoes, hard hat, safety goggles, gloves, dust mask and any other appropriate protective clothing in the work area.
-
Do no indulge in horseplay. Distraction can cause accidents.
-
Use only proper cleaning solvents to clean parts. Use only cleaning solvents which meet current safety and health standards. Use cleaning solvents in a well ventilated area.
-
Do NOT clean machine or any parts with diesel fuel or any other petroleum distillates.
-
Do not operate the machine with broken or damaged parts.
-
This tool is not designed for working in explosive atmospheres.
Refer All Communications to the Nearest Novatek Corporation Office or Distributor. Printed in U.S.A.
SECTION I
INTRODUCTION
This operation and maintenance manual is furnished with each NOVAIR 2000.
It outlines the general use and maintenance requirements for efficient and
safe operation.
READ ALL INSTRUCTIONS AND DATA IN THIS OPERATION AND MAINTENANCE MANUAL
PRIOR TO OPERATION OF THIS EQUIPMENT.
These instructions are for your protection and convenience. Please read them
carefully. Failure to follow these precautions could result in injury, death
or damage. Whenever using electric powered equipment, basic safety precautions
should be followed. If after reading this manual you still have questions,
contact a NOVATEK authorized distributor or NOVATEK directly by dialing
1-866-563-7800.
SECTION II
GENERAL DESCRIPTION
- The NOVAIR 2000 is a portable, electrically powered Air Filtration machine, designed and manufactured by Novatek Corp. The machines function is to filter air and remove suspended airborne particulates.
- This unit has a three stage filtering system. The Pre-Filter stage captures the bulk of the dust and debris. The second stage utilizes a two-ply Ring Filter that captures any dust and dirt able to penetrate the
- Pre-Filter. The final stage is the 99.97% – 0.3 micron HEPA Filter or the 5 micron general purpose filter. The HEPA filter is utilized in abatement work or areas where an extremely high level of filtration is desired. The general purpose filter is utilized when trying to reduce visible air born particulates that are deemed non hazardous.
- The NOVAIR 2000 requires a 110/115V – 15 Amp, single phase power source.
WARNING
Do not use circuits exceeding specified voltage. Higher voltage will damage
controls and could cause shock or fire hazard.
SECTION III
ROUTINE MAINTENANCE
Inspect the unit for any loose or damaged parts prior to use.
CAUTION : Be sure power supply is in the OFF position prior to inspection!
- Clean the surfaces of the unit to remove accumulated dust or dirt. Do not use petroleum distillates, solvents, or thinners as cleaning agents. Remove any accumulated dust and dirt from control panel.
- Periodic checks should be made of the filter brackets to ensure thumbscrews and knobs are secure.
- Filters should be checked daily and replaced if needed. This will help ensure proper air flow and extend motor life.
- Inspect ALL power connection. Be sure that the recessed plug is secure to the panel. If recessed plug is not secured, electrical shock or shortage may occur.
- Inspect your power cords connections for breaks, scorched areas, melting, oxidation, or signs of wear. If cord shows ANY of these signs, replace.
CAUTION : Do not tamper with or modify the blower housing, control panel, drive motor, or wiring scheme. Tampering or modifications could result in premature wear or failure and will void factory warranty.
CONTROL DESCRIPTIONS
-
Power Switch
Switch used to turn on your Novair. Select either high or low settings depending on the desired volume of air to be filtered. -
Circuit Breaker
This is attached to the units main power supply to assist in protecting the blower motor from power surges. The circuit breaker also helps protect the operator against electrical shock or hazards. -
Differential Pressure Gauge
This is used to determine filter efficiency. The DPG measures negative pressure on the clean side of the filters. As the Filters load with dust and debris, the negative pressure will increase and move the needle of the DPG. A new filter will register 1.0-1.5” of water column. A fully loaded filter will register approximately 3.0-3.5” of water column. -
Barbed Fitting
Inlet used to measure pressure of surrounding ambient air. -
Male Recessed Plug
Firmly insert the female end of a proper gauge extension cord to power the machine.
CAUTION : A loose, corroded, ill fitted or damaged extension cord can cause premature failure and void your warranty. -
Audible Alarm – (Optional Feature)
Audibly alerts the operator when filters are loaded or when air flow is greatly decreased. The alarm will sound once the pressure gauge reaches 2.8-3.2” of water column. -
Visual Light – (Optional Feature)
Visually alerts the operator when filters are loaded or when air flow is greatly decreased. The alarm will light once the pressure gauge reaches 2.8-3.2” of water column.
F2102 Control Panel
SECTION IV
PRIOR TO USE
- Remove any excess dust/dirt from exterior housing and control panel.
- Be sure the HEPA Filter and Pre-Filters are installed properly with a positive seal.
- Insure the unit is connected to a dedicated 15Amp, 110/115 volt circuit.
- Make sure unit is safely positioned as not to impede any entrances or exits of the work area.
- If applicable, check exhaust port connections for tight seal.
CAUTION : Insure your power cord is securely attached to the male recessed plug. If any movement or play is detected, change power cord immediately! If connection remains loose, immediately replace the male recessed plug.
OPERATION
- When utilized in containment, the Novair should be positioned a minimum distance away from the entrance and located towards the center of the containment.
- When using a HEPA filter, insure the filter is correctly installed and sealed. Anchor and secure the filter utilizing the supplied retaining brackets.
- Install the Ring Filter and Pre-Filter pad into unit.
- Position the unit on a flat level surface and secure the casters using the lock feature.
- Insert the female end of your 12/3, UL listed cord, into the male recessed plug on control panel.
- To begin operation, depress the power switch to either the low or high position. Locate the differential pressure gauge located on the control panel. The gauge will register between 1.0” – 2.5” of water column. This is the initial reading when filters are new and unused. This reading will incrementally increase as filters become loaded with dust and debris. When the gauge reaches 3.0” – 3.4” of water column; either one or all of the filters are loaded and in need of replacement.
- Pressing the power switch to the left will operate the unit in “Low” mode equivalent to 1000 CFM.
- Pressing the power switch to the right will operate the unit in “High” mode equivalent to 2000 CFM.
SECTION V
REPLACEMENT OF FILTERS
The work atmosphere will impact the frequency of filter replacements. As
filters begin to load, the reading of the pressure gauge will increase
incrementally. When the Pressure gauge reads 3.0” – 3.4” or when airflow is
greatly reduced, check the condition of filters.
CAUTION : If applicable, wear personal protective equipment during filter replacement. Please observe all Federal, State, and Local regulations regarding the handling and disposal of hazardous materials.
PRE-FILTER REPLACEMENT
- Set the power switch (diagram #20.1, item #3) to the off position. Disconnect power supply.
- Remove Black Filter Door (diagram #20.1, item #10) to expose the filters.
- Reach in and remove the Pre-Filter (diagram #20.1, item #18). Dispose of Pre-Filter accordingly.
- Replace the discarded Pre-Filter with a new Pre-Filter.
- Reinsert the Black Filter Door.
- Insert the female end of your power cord into the Male recessed plug (diagram #20.1, item #1), and set the power switch to the “High” position. If the reading on the pressure gauge exceeds 3.0” – 3.4” of water column, the Ring Filter (diagram# 20.1, item #17) should be inspected.
RING FILTER REPLACEMENT
- Follow steps A-D listed above referencing Pre-Filter replacement.
- Reach in and remove the Ring Filter (diagram# 20.1, item #17). Dispose of Ring Filter accordingly.
- Replace the discarded filter with a new unused Ring Filter.
- Reinstall the Pre-Filter.
- Reinsert the Black Filter Door.
- Insert the female end of your power cord into the male recessed plug (diagram #20.1, item #1), and set the power switch to the “High” position. If the reading on the pressure gauge exceeds 3.0-3.4” of water column, the HEPA or General Purpose Filter should be inspected.
HEPA/GENERAL PURPOSE FILTER
- Follow steps A-D listed above for Ring Filter replacement.
- Locate the bracket thumbscrews (diagram #20.1, item #12). Loosen the four bracket thumbscrews by turning them counter clockwise.
- With all four thumbscrews loose, push the top of the filter brackets (diagram #20.1, item #11) inward towards each other, and remove from the front of the unit.
- Firmly grasp the right and left sides of the HEPA or General Purpose Filter (diagram #20.1, item #16), and pull the filter directly towards you. Remove the used filter and dispose of accordingly
- Carefully inspect the replacement HEPA/General Purpose Filter gaskets for cracks, gaps or defects. Any defective gaskets must be replaced.
- The HEPA and General Purpose Filters have two sides; one side has a gasket, the other does not. Insert replacement HEPA or General Purpose Filter, gasket side first, into machine and press firmly against the housing’s internal rib.
- Reinstall the filter brackets. Once the brackets are installed, turn the thumbscrews clockwise until tight. This will secure the main filter.
- Reinstall Ring Filter and Pre-Filter. (Reference Pre-Filter and Ring Filter Replacement).
- Reinsert the Black Filter Door.
SECTION VI
WIRING DIAGRAM
SECTION VII
20.1 DIAGRAM OF UNIT AND CONTROL PANEL
SECTION VIII
SAFETY
Novatek Negative Air Machines are highly efficient systems designed to
reduce air borne particulates. To insure proper operation, the following
safety precautions should be strictly adhered to:
-
Do not leave machine unattended while in operation. Turn OFF electric supply and disconnect from power source when not in use and/or before servicing.
-
Do not operate with damaged or malfunctioning parts. If the unit is not working as intended, return to an Authorized Repair and Service Center.
NOTE : Always replace worn or damaged components with genuine NOVATEK parts. Failure to comply could result in equipment failure and will void warranty. -
Remove any loose clothing and adornments prior to operation.
-
Keep outer surfaces free of dirt and debris. Be sure all controls clean and functioning properly.
-
Turn off power prior to any filter inspection and replacement.
-
Do not operate unit with flammable or combustible liquids or gases present.
-
Do not operate the machine in wet conditions. Failure to do so could result in electrical shock or death.
-
Never operate the unit if there is any possibility of contact with the blower wheel.
-
It is the responsibility of the unit owner to ensure that all equipment is maintained in safe and efficient operating condition.
-
The stacking of machines is limited to three units. Do not house stacked machines in areas hotter than 100 degrees Fahrenheit. (Failure to comply will void the warranty.)
TROUBLESHOOTING
-
The unit is plugged in and turned on, but will not operate.
Inspect the circuit breaker located on the front control panel. If the center of the circuit breaker is extended, this indicates the circuit breaker requires re-setting. Reset the circuit breaker by depressing the center of the circuit breaker. If the center fails to remain depressed, replace the circuit breaker immediately -
If unit continues not to function.
Check the power supply in the work area. Be sure power is being supplied to the unit. -
If at this point, unit still will not operate
Contact your nearest authorized Novatek service center.
NOVATEK CORPORATION LIMITED WARRANTY
- ELECTRICAL COMPONENTS utilized in the NOVAIR product line are warranted to be free from defects in material and workmanship for a period of 180 DAYS from date of purchase from Novatek. The remaining materials in the NOVAIR are warranted to be free from defects in material and workmanship for a period of 1 YEAR from the date of purchase from Novatek. This warranty does not extend to accessories.
- This warranty applies only to UNITS purchased from the NOVATEK CORPORATION or an AUTHORIZED RETAILER. This warranty does not apply to any UNIT which has been abused, misused, modified or repaired by someone other than the NOVATEK CORPORATION or its authorized repair center.
- If a UNIT proves defective in materials or workmanship within one year of purchase, it should be returned to NOVATEK CORPORATION via pre-paid transportation. The return must be accompanied by a RETURN MERCHANDISE AUTHORIZATION
- NUMBER (R.M.A. #) obtained from NOVATEK CORPORATION. The Return authorization number must be clearly marked on the outside of the package being returned. Any returned merchandise that does not have a return merchandise authorization number clearly marked on the outside of the package will be refused and returned to sender.
- Warranty claims will only be considered upon proof of purchase date. NOVATEK CORPORATION will, at its discretion, REPAIR or REPLACE DEFECTIVE PARTS. Repairs or replacements parts are warranted as above for the remainder of the original warranty period. The sole liability of NOVATEK CORPORATION and the user’s exclusive remedy under this warranty is limited to the repair or replacement of the defective product.
- THERE ARE NO OTHER WARRANTIES EXPRESSED OR IMPLIED AND NOVATEK CORPORATION SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES OR ANY OTHER EXPENSES OR REPAIR OR REPLACEMENT AS DESCRIBED ABOVE.
All warranty claims should be forwarded to:
NOVATEK CORPORATION
254 Welsh Pool Rd
Exton, PA 19341
ATTENTION : CLAIM AND SERVICE DEPARTMENT
R.M.A. # ____
CALL Toll-Free at 1-866-563-7800 for
your RMA number PRIOR TO SHIPPING.
Also include a brief description of the problem as well as a phone number,
contact name and return address in case NOVATEK CORPORATION service personnel
has to get in contact with you.
www.novatekco.com toll free 866.563.7800 tele 610.363.7800 fax 610.363.9620 sales@novatekco.com
FAQ
Q: What should I do if I encounter a problem with the machine?
A: Refer all communications to the nearest Novatek Corporation office or
distributor for assistance.