BEGA 85150 Performance Floodlight
Instructions for use
Dimensions
Application
Performance floodlight with G½ mounting bush.
The floodlight can be bolted together with any female thread G½ according to
ISO 228 supplied by others or to BEGA accessories. For a variety of interior
and exterior lighting applications.
Product description
Luminaire made of aluminium alloy, aluminium and stainless steel BEGA Unidure®
coating technology Colour graphite or silver
Matt safety glass Silicone gasket Reflector surface made of pure aluminium
BEGA Hybrid Optics®
Rotation range of floodlight 350°
Swivel range -30°/+100°
Mounting bracket with G½ threaded connection
Thread length: 14mm Connecting cable X05BQ-F 5G1mm² Cable length 1m
BEGA Ultimate Driver®
Complies with flicker requirements in accordance with IEEE 1789, DIN IEC/TR
63158, DIN IEC/TR 61547-1 LED power supply unit 220-240 V 0/50-60 Hz DC
176-264 V
DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire Safety class I Protection class IP 65
Dust-tight and protection against water jets Impact strength IK07 Protection
against mechanical
impacts < 2 joule
– Conformity mark Wind catching area: 0.021 m²
Weight: 2.1 kg
This product contains light sources of energy efficiency class(es) F
Safety The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend
separate overvoltage protection components. You can find them on our website
at www.bega.com.
The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71320.
Installation
Screw the floodlight G½ threaded connection firmly into the on-site G½ female
thread or BEGA accessory.
G½ threaded connection torque = 40Nm.
Secure the screw connection from loosening on site (if provided with locking
screw S, see fig. A).
Check the earth conductor connection between the G½ threaded connection and
the on-site G½ female thread.
Adjust floodlight:
Undo hexagon socket screw (wrench size 5 mm) and hexagon nut (wrench size 27
mm) and set the desired beam direction (see sketch B, C).
Torque:
Hexagon socket screw = 7 Nm
Hexagon nut = 35 Nm
Secure bolted connection Gß against loosening by tightening the hexagon socket
screws (wrench size 2 mm).
The electrical connection must be carried out with matching protection class
and safety class, strain-relieved, with suitable connection terminals (not
included in the scope of delivery) at the luminaire power supply cable.
Note correct configuration of the mains supply cable. The earth conductor is
connected at the green-yellow ( ), the phase to the brown (L), and the neutral
conductor to the blue (N) marked wire.
The connection of the control cables is achieved by means of the both leads
marked with DALI. In case these leads are not used the luminaire will be
operated at full light output.
Lamp
Module connected wattage 25.7 W
Luminaire connected wattage 28.5 W
Rated temperature ta =25 °C
Ambient temperature ta max =30 °C
85 150K3
Module designation LED-1145/930
Colour temperature 3000 K
Colour rendering index CRI >90
Module luminous flux 3140 lm
Luminaire luminous flux 1613 lm
Luminaire luminous efficiency 56,6 lm/W
85 150K4
Module designation LED-1145/940
Colour temperature 4000 K
Colour rendering index CRI >90
Module luminous flux 3300 lm
Luminaire luminous flux 1695 lm
Luminaire luminous efficiency 59,5 lm/W
Lighting technology
Focused light distribution with minimal diffuse light percentage.
Half beam angle 10°
For special lighting applications, an optical filter can be used to change the
symmetrical light cone into a flat beam light distribution.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Maintenance
The connecting cable between mounting box and floodlight has to be inspected
regarding obvious damages and has to be replaced by a qualified electrician
only.
Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.
Replacing the LED module
The designation of the LED module is noted on a separate label in the
luminaire or on the underside of the specific LED module.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by
qualified persons using standard tools.
Disconnect the system.
Open the floodlight:
Undo locking pin (hexagon socket head wrench size 2.5 mm) on the back side of
the floodlight housing.
Remove the trim ring along with the safety glass and reflector by twisting it
counterclockwise. Replace LED module.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Place trim ring with glass and reflector on the floodlight housing in such a
way that the notches in the trim ring and floodlight housing align on top to
each other.
Twist on the trim ring clockwise as far as the stop. Tighten locking pin.
Accessories
71 290 Optical filter flat beam
71332 Shield
71 337 Cylindrical shield
70 214 Pole cap for pole ø 48 mm
70 248 Pole cap for pole ø 60 mm
70 245 Mounting box
70 252 General fastener
70 280 Tube clamp G½
70 283 Screw clamp
70 379 Cross beam G½
70 889 Tension belt
For the accessories a separate instructions for use can be provided upon request.
Spares
Trim ring graphite with glass 25 000 252
Trim ring silver with glass 25 000 253
LED power supply unit DEV-0353/700
LED module 3000 K LED-1145/930
LED module 4000 K LED-1145/940
Reflector 75 005 076
Gasket housing 83 000 521
Gasket Abschlussring 83 002 222
4/4 BEGA Gantenbrink-Leuchten KG · Postfach 3160