BEGA 85235 Performance Floodlight Mounting Box Instruction Manual
- June 1, 2024
- BEGA
Table of Contents
- Dimensions
- Application
- Product Description
- Safety
- Overvoltage Protection
- Installation
- Lamp
- 85 235K3
- 85 235K4
- Lighting Technology
- Cleaning · Maintenance
- Maintenance
- Replacing the LED module
- Accessories
- Spares
- Customer Support
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BEGA 85235 Performance Floodlight Mounting Box
Dimensions
Application
Performance floodlight with mounting box.
For a variety of interior and exterior lighting applications.
BEGA Ultradark Optics® offer a maximum of illumination and eye comfort due to
a minimised diffuse light percentage and highly efficient glare suppression.
Product Description
Luminaire made of aluminium alloy,
aluminium and stainless steel
BEGA Unidure® coating technology
Colour graphite or silver
Matt safety glass
Internal louvres and polymer lens
BEGA Ultradark Optics®
Louvres and interior surface of anti-glare ring
with maximum light-absorbing ultra-black
nano-coating
Rotation range of floodlight 350°
Swivel range -25°/+90°
Mounting box with 2 fixing holes
ø 4.8mm · 67mm spacing
2 cable entries for through-wiring of mains
supply cable ø 7-10.5mm, max. 5G1.5@
Connecting terminal 2.5@
with plug connection
Earth conductor connection
BEGA Ultimate Driver®
Complies with flicker requirements in
accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit
220-240 V 0/50-60 Hz
DC 176-264 V
DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains
and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect
temperature-sensitive components without
switching off the luminaire
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK06
Protection against mechanical
impacts < 1 joule
– Conformity mark
Wind catching area: 0.031 m²
This product contains light sources of energy
efficiency class(es) E, F
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage Protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend
separate overvoltage protection components.
You can find them on our website at www.bega.com.
The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71320.
Please note:
Contact with the inner surface of the luminaire reflector should be avoided in order to permanently protect the special stray light minimising properties of the nano-coating.
Installation
LED are high-quality electronic components! Please avoid touching the light
output opening of the LED directly during installation or relamping.
Undo hexagon socket head screws (wrench size 3 mm) at the mounting box and
remove mounting plate.
Disconnect the earth conductor connection from the plug connection.
Pass the power connecting cable through the cable entry in the mounting plate.
Note position of application of the mounting plate “arrow down”.
Fix the mounting plate with enclosed or any other suitable fixing material
onto the mounting surface.
Be sure to use the gasket rings supplied.
Make earth conductor connection.
Push silicone sleeves over the lines and make electrical connection to
terminal (plug connection).
For digital control please use the 2-pole plug connector DA, DA.
In case this connector is not used the luminaire will be operated at full
light output.
Push plug into coupler as far as it will go.
Connect the floodlight unit’s green and yellow protective earth conductor to
the terminal marked in the mounting plate.
Make sure that gasket is positioned correctly.
Place floodlight unit onto the mounting plate as displayed in the sketch,
align and screw together firmly.
Adjustment of beam direction:
Undo joint screw (hexagon socket head wrench size 6 mm) and set the desired
beam direction.
Tighten the joint screw.
Torque = 12Nm.
Lamp
Module connected wattage | 25.2 W |
---|---|
Luminaire connected wattage | 28 W |
Rated temperature | ta=25 °C |
Ambient temperature | ta max=35 °C |
85 235K3
Module designation | LED-1254/930 |
---|---|
Colour temperature | 3000 K |
Colour rendering index | CRI >90 |
Module luminous flux | 2825 lm |
Luminaire luminous flux | 1426 lm |
Luminaire luminous efficiency | 50,9 lm/W |
85 235K4
Module designation | LED-1254/940 |
---|---|
Colour temperature | 4000 K |
Colour rendering index | CRI >90 |
Module luminous flux | 3070 lm |
Luminaire luminous flux | 1550 lm |
Luminaire luminous efficiency | 55,4 lm/W |
Lighting Technology
Symmetrically focused broad spread light distribution with minimal diffuse
light percentage.
Half beam angle 56°
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits. Do not use high pressure cleaners.
Maintenance
The connecting cable between mounting box and floodlight has to be inspected regarding obvious damages and has to be replaced by a qualified electrician only
Replacing the LED module
The designation of the LED module is noted on a separate label in the
luminaire or on the underside of the specific LED module.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by a
qualified person using commercially available tools.
Disconnect the system from the power supply.
Open the floodlight:
Loosen the locking pin (hexagon socket wrench SW2.5) on the back of the
floodlight housing. Remove the trim ring along with the safety glass and
reflector by twisting it anti-clockwise.
Please note:
Contact with the inner surfaces of the louvres and luminaire reflector should
be avoided in order to permanently protect the special stray light-minimising
properties of the nano-coating.
Grasp the louvres from the outside and lift them out. Loosen the three
mounting screws (Torx drive T20) and lift the lens holder (with the loosely
inserted lenses) upward horizontally out of the housing.
Replace LED module.
Please follow the installation instructions for the LED module.
Install in reverse order.
When installing the lens holder, make sure that the LED connecting cable is
not pinched.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Place the trim ring with glass and reflector on the floodlight housing so that
the notches in the trim ring and luminaire housing sit on top of each other.
Twist on the trim ring clockwise as far as the stop. Screw in the locking pin.
Accessories
71333 Shield
71 338 Cylindrical shield
For the accessories a separate instructions for use can be provided upon request.
Spares
Spare glass internal | 14 001 631 |
---|---|
Trim ring graphite with glass | 25 000 281 |
Trim ring silver with glass | 25 000 282 |
LED power supply unit | DEV-0270/1200i |
LED module 3000 K | LED-1254/930 |
LED module 4000 K | LED-1254/940 |
Gasket housing | 83 001 579 |
Gasket mounting box | 83 001 839 |
Gasket trim ring | 83 002 306 |
Customer Support
4/4 BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden ·
info@bega.com ·
www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>