BEGA 50593K27 Recessed Ceiling Luminaire For Indoor Use Instruction Manual

June 1, 2024
BEGA

BEGA LOGO Technical amendments reserved
50 593
Recessed ceiling luminaire for indoor use
BEGA 50593K27 Recessed Ceiling Luminaire For Indoor
UseInstructions for use

**Application

**

Recessed ceiling luminaire · indoor luminaire partially satin matt crystal glass inside and aluminium alloy housing.
For installation into ceilings with a shallow depth in interior areas.

Product description

Recessed ceiling luminaire »ACCENTA PURE«
Die-cast aluminium housing
Crystal glass, partially satin matt inside
Reflector of anodised pure aluminium
Ceiling trim ring made of metal, colour white
Recessed opening ø 68 mm
Required installation depth 60 mm
Fixing is achieved by using 2 adjustable wedge-shaped claws
External LED power supply unit
220-240 V ≂ 0/50-60 Hz
DC 176-280 V
DALI controllable
Number of DALI addresses: 1
A basic isolation exists between power cable and control line
Safety class II Icon
– Safety mark
– Conformity mark
Weight: 0.4 kg
This product contains light sources of energy efficiency class(es) E

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Lamp

Module connected wattage 8.5 W
Luminaire connected wattage 10.4 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 35 °C

50 593 K27

Module designation LED-0923/927
Colour temperature 2700 K
Colour rendering index CRI > 90
Module luminous flux 1155 lm
Luminaire luminous flux 549 lm
Luminaire luminous efficiency 52,8 lm / W

50 593 K3

Module designation LED-0923/930
Colour temperature 3000 K
Colour rendering index CRI > 90
Module luminous flux 1200 lm
Luminaire luminous flux 570 lm
Luminaire luminous efficiency 54,8 lm / W

Installation

Luminaire housing must not be installed in heat-insulating material.
The recessed opening will be covered by the frame of the luminaire.
Fixing of the luminaire is achieved by using 2 adjustable wedge-shaped claws.

Installation into false ceilings
A recessed opening of ø 68 mm is necessary to accept the luminaire housing. Free space depth min. 60 mm (see sketch).
The claws catch the panel from the reverse side. If minimum thickness of the panel is less than 3 mm it must be reinforced from the reverse side. Maximum thickness of the panel must be no more than 20 mm.
The electrical connection must be made on site in the appropriate safety class on the LED power supply unit connecting cable. A distribution box must be used.
Ensure the correct assignment of the connecting cable. Establish the mains connection on the brown (L) and blue (N) wires. The connection of the control cables is achieved by means of the both leads marked with – DALI.
In case these leads are not used the luminaire will be operated at full light output.

Push external LED-power supply unit and luminaire housing into ceiling cut- out.
Luminaire housing and external LEDpower supply unit must not be installed in heat-insulating material.
Hand-tight screws of claw fasteners evenly. Lead enclosed ceiling frame ring over the screw-neck of the glass and push it down the gasket.
Make sure that gasket is positioned correctly. Insert glass with mounted reflector and frame ring by turning it clockwise into luminaire housing.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.
Defective glass must be replaced.

Replacement of the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
Disconnect from main supply.
Unscrew glass with ceiling frame ring from luminaire housing by turning it counterclockwise.
Please follow the installation instructions for the LED module.
Check gasket. Screw in glass with ceiling frame ring by turning it clockwise beyond the stop.
Defective glass must be replaced.

Spares

Spare glass 11 003 054 410 RG
LED power supply unit DEV-0434/250
LED module 2700 K LED-0923/927
LED module 3000 K LED-0923/930
Trim ring 72 009 561 L
Reflector 76 001 209

BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com
www.bega.com

Documents / Resources

| BEGA 50593K27 Recessed Ceiling Luminaire For Indoor Use [pdf] Instruction Manual
50593K27 Recessed Ceiling Luminaire For Indoor Use, 50593K27, Recessed Ceiling Luminaire For Indoor Use, Luminaire For Indoor Use, Indoor Use, Use
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals